Secondary steel has to be provided across__________ of flanged beams
[ A ] Full effective width of flange
[ B ] The width of web
[ C ] Half of the width of flange
[ D ] None of the above.

1 Answer

Answer :

[ A ] Full effective width of flange

Related questions

Description : If depth of slab is 10 cm, width of web 30 cm, depth of web 50 cm, centre to centre distance of beams 3 m, effective span of beams 6 m, the effective flange width of the beam, is (A) 200 cm (B) 300 cm (C) 150 cm (D) 100 cm

Last Answer : Answer: Option C

Description : An intermediate T-beam reinforced with two layers of tensile steel with clear cover 13 cm encasted with the floor of a hall 12 metres by 7 metres, is spaced at 3 metres from adjoining beams and if the width of the beam is ... breadth of the flange is (A) 300 cm (B) 233 cm (C) 176 cm (D) 236 cm

Last Answer : Answer: Option C

Description : The ratio of the thickness of web to that of flange of steel rolled structural beams and channels is (A) Less than 1 (B) Equal to 1 (C) Greater than 1 (D) Less than 1 in beams but greater than 1 in channels

Last Answer : Answer: Option A

Description : The width of the flange of a T-beam, which may be considered to act effectively with the rib depends upon (A) Breadth of the rib (B) Overall thickness of the rib (C) Centre to centre distance between T-beams (D) All the above

Last Answer : Answer: Option D

Description : In grillage foundations, distance between flanges of grillage beams, is kept (A) 40 cm (B) Equal to flange width (C) Twice the flange width (D) Maximum of (a), (b) and (c)

Last Answer : Answer: Option C

Description : In grillage foundations a minimum 15 cm cover is provided on (A) Upper flange of top tier (B) Lower beam of lower tier (C) Ends of external beams (D) None to these

Last Answer : Answer: Option B

Description : The width of the flange of a L-beam, should be less than (A) One-sixth of the effective span (B) Breadth of the rib + four times thickness of the slab (C) Breadth of the rib + half clear distance between ribs (D) Least of the above

Last Answer : Answer: Option D

Description : Flanged beams are preferred when the concrete in the slab is on the [ A ] compression side of the beam [ B ] tension side of the beam [ C ] may be compression side or tension side of the beam [ D ] none of the above

Last Answer : [ A ] compression side of the beam

Description : Flanged beams are preferred when the concrete in the slab is on the [ A ] compression side of the beam [ B ] tension side of the beam [ C ] may be compression side or tension side of the beam [ D ] none of the above

Last Answer : [ A ] compression side of the beam

Description : The width of the flange of a T-beam should be less than (A) One-third of the effective span of the T-beam (B) Distance between the centres of T-beam (C) Breadth of the rib plus twelve times the thickness of the slab (D) Least of the above

Last Answer : Answer: Option D

Description : The Percentage of steel in T-beam mainly based on [ A ] Flange width [ B ] Rib width [ C ] Flange depth [ D ] None of the above.

Last Answer : [ B ] Rib width

Description : A singly reinforced concrete beam of 25 cm width and 70 cm effective depth is provided with 18.75 cm2 steel. If the modular ratio (m) is 15, the depth of the neutral axis, is (A) 20 cm (B) 25 cm (C) 30 cm (D) 35 cm

Last Answer : Answer: Option C

Description : Find the shear stress in a flange at the junction of hub in rigid flanged coupling if torsional moment is 2980N-m and diameter of hub being 125mm. Also the thickness of flange is 25mm. a) 6.77N/mm2 b) 10.24N/mm2 c) 4.84N/mm2 d) 4.22N/mm2

Last Answer : c) 4.84N/mm2

Description : Which of the following is not required to be marked on an ASME B16.5 flange or flanged fitting? a) Manufactures name or trademark. b) Material. c) Ratting class and "B16". d) Temperature.

Last Answer : d) Temperature.

Description : What pressure does ASME B16.5 limit flanged fittings to during system hydrostatic testing? a) 1.5 times the 100°F pressure rating, rounded to next highest 25psi. b) 1.5 times the flange class. c) The maximum pressure rating for the flange. d) The flange class plus 250psi.

Last Answer : a) 1.5 times the 100°F pressure rating, rounded to next highest 25psi. b) 1.5 times the flange class.

Description : When applying to pressure ratings listed in ASME B16.5 at high or low temperatures which of the following must be considered? a) Risk of leakage due to forces and moments developed. b) Bursting of the flanged fitting. c) The bolting forces at the flange. d) All of the above.

Last Answer : a) Risk of leakage due to forces and moments developed.

Description : When flanged fittings are to be used at temperatures below -20°F, what pressure rating is to be used? a) The pressure rating at the actual service temperature, found by interpretation. b) The pressure ... to the flange class. d) Flanges complying with ASME B16.5 may not be used below -20°F.

Last Answer : b) The pressure rating at -20°F.

Description : A flanged joint is composed of all but which of the following? a) The flange b) The bolts. c) The assembly method d) The gasket.

Last Answer : b) The bolts

Description : The flange markings on a flanged fitting indicate which of the following? a) Pressure. b) Pressure at a specified temperature. c) Flange class. d) Maximum pressure.

Last Answer : c) Flange class.

Description : Pick up the correct statement from the following: (A) The roof slabs of multi-storeyed buildings are constructed monolithically to carry the various floor loads (B) The beams of multi-storeyed ... slab is spanned across the secondary beams provided between the main beams (D) All of these

Last Answer : Answer: Option D

Description : A grillage foundation (A) Is provided for heavily loaded isolated columns (B) Is treated as spread foundation (C) Consists of two sets of perpendicularly placed steel beams (D) All the above

Last Answer : Answer: Option D

Description : In singly reinforced beams, steel reinforcement is provided in (a) Compressive zone (b) Tensile zone (c) Neutral zone (d) All the above

Last Answer : (b) Tensile zone

Description : The allowable shear stress in stiffened webs of mild steel beams decreases with (a) Decrease in the spacing of the stiffeners (b) Increase in the spacing of the stiffeners (c) Decrease in the effective depth (d) Increase in the effective depth

Last Answer : (b) Increase in the spacing of the stiffeners

Description : The allowable shear stress in the web of mild steel beams decreases with (a) Decrease in h/t ratio (b) Increase in h/t ratio (c ) Decrease in thickness (d) Increase in height Where h is the height and t is the thickness

Last Answer : (b) Increase in h/t ratio

Description : A T-beam behaves as a rectangular beam of a width equal to its flange if its neutral axis (A) Remains within the flange (B) Remains below the slab (C) Coincides the geometrical centre of the beam (D) None of these

Last Answer : Answer: Option A

Description : For beams of uniform strength, if depth is constant,  (A) Width b M (B) Width b M (C) Width b 3 M (D) Width b 1/M

Last Answer : (A) Width b M

Description : The thickness of base slab of a retaining wall generally provided, is (A) One half of the width of the stem at the bottom (B) One-third of the width of the stem at the bottom (C) One fourth of the width of the steam at the bottom (D) Width of the stem at the bottom

Last Answer : Answer: Option D

Description : A T-section beam having flange 180mm wide and 20 mm thick and web 150 mm long and 20 mm thick carries a udl of 80 kN/m over an effective span of 8 m. Calculate the maximum bending stress.

Last Answer : Solution :

Description : If permissible working stresses in steel and concrete are respectively 1400 kg/cm2 and 80 kg/cm2 and modular ratio is 18, in a beam reinforced in tension side and of width 30 cm and having effective depth 46 cm, the lever arms of the section, is (A) 37 cm (B) 38 cm (C) 39 cm (D) 40 cm

Last Answer : Answer: Option D

Description : The stresses developed in concrete and steel in reinforced concrete beam 25 cm width and 70 cm effective depth, are 62.5 kg/cm2 and 250 kg/cm2 respectively. If m = 15, the depth of its neutral axis is (A) 20 cm (B) 25 cm (C) 30 cm (D) 35 cm

Last Answer : Answer: Option C

Description : Pick up the correct statement from the following: (A) Construction joints in columns are provided a few cm below the junction of beam (B) Construction joints in columns are provided at the bottom ... (C) Construction joints in beams and slabs are provided within middle third (D) All the above

Last Answer : Answer: Option D

Description : Vertical construction joints are provided where the shearing forces are minimum in the case of (A) Slabs (B) Beams (C) Girders (D) All of these

Last Answer : Answer: Option D

Description : The effective width of a column strip of a flat slab, is (A) One-fourth the width of the panel (B) Half the width of the panel (C) Radius of the column (D) Diameter of the column

Last Answer : Answer: Option B

Description : Side looking 700 2MHZ probe is tested for detecting. (i) Flaw in head (ii) Flaw in web (iii) Half moon crack in flange.* (iv) For all above.

Last Answer : iii) Half moon crack in flange

Description : The effective depth of a T-beam is the distance between the (a) Centre of the flange and the top of the tensile reinforcement (b) Top of the flange and the centre of the tensile ... centre of the tensile reinforcement (d) Centre of the flange and the bottom centre of the tensile reinforcement

Last Answer : (b) Top of the flange and the centre of the tensile reinforcement

Description : The breadth of the flange of a T-beam is (a) 1/3rd of the effective span of the T-beam (b) Twelve times the depth of slab plus breadth of rib. (c) Centre to centre distance between the adjacent beam. (d) Least of (a) , (b) or (c)

Last Answer : (d) Least of (a) , (b) or (c)

Description : Basic values of span/effective depth ratios to be used for beams and slabs with spans [ A ] Less than 10m [ B ] Less than 20 m [ C ] 10 m- 20 m [ D ] More than 20 m

Last Answer : [ A ] Less than 10m

Description : The principle used for control of deflection in beams and slabs. [ A ] Maxwell method [ B ] Mohr‟s theorem [ C ] Span to effective depth ratio [ D ] Span to overall depth ratio.

Last Answer : [ C ] Span to effective depth ratio

Description : Steel beam theory is used for (A) Design of simple steel beams (B) Steel beams encased in concrete (C) Doubly reinforced beams ignoring compressive stress in concrete (D) Beams if shear exceeds 4 times allowable shear stress

Last Answer : Answer: Option C

Description : According to the steel beam theory of doubly reinforced beams (A) Tension is resisted by tension steel (B) Compression is resisted by compression steel (C) Stress in tension steel equals the stress in compression steel (D) All the above

Last Answer : Answer: Option D

Description : Mild steel is used for (A) Structural works in beams, joints and girders (B) Small sized water pipes (C) Columns and struts (D) None of these

Last Answer : Answer: Option A

Description : The application of elastic theory to the beams is based on the assumption that (a) At any cross-section, plane sections before bending remain plane after bending (b) All tensile stresses are taken ... reinforcement is free from initial stresses when it is embedded in concrete. (d) All of the above

Last Answer : (d) All of the above

Description : The Maximum percentage of steel in tension allowed for beams [ A ] 0.2 [ B ] 0.4 [ C ] 2 [ D ] 4

Last Answer : [ A ] 0.2

Description : The spacing of stirrups in doubly reinforced beams should be least of the following (i)Least Lateral dimension (ii)Sixteen times the diameter of longitudinal steel (iii)Forty eight times the diameter of transverse reinforcement [ A ] i [ B ] i and ii [ C ] i and iii [ D ] i, ii and iii

Last Answer : [ D ] i, ii and iii

Description : The spacing of stirrups in doubly reinforced beams should be least of the following (i)Least Lateral dimension (ii)Sixteen times the diameter of longitudinal steel (iii)Forty eight times the diameter of transverse reinforcement [ A ] i [ B ] i and ii [ C ] i and iii [ D ] i, ii and iii

Last Answer : [ D ] i, ii and iii

Description : Steel Beam theory is a method of designing [ A ] Balanced sections [ B ] Critical sections [ C ] Singly reinforced beams [ D ] Doubly reinforced beams

Last Answer : [ D ] Doubly reinforced beams

Description : The Maximum shear stress in Slabs should not exceed -------- the maximum values allowed for beams. [ A ] Half Of [ B ] One-Fourth Of [ C ] Twice [ D ] Those Given In

Last Answer : [ A ] Half Of

Description : Consider the following statements in respect of design of web and flange as splices: 1. Flange splice shall be designed for actual BM at the section. 2. Flange splice shall be designed to resist the actual shear at the section. 3. Web ... are correct? (a) 1 and 3 (b) 2 and 3 (c) 3 and 4 (d)1 and 4

Last Answer : (a) 1 and 3

Description : Full amount of extra width of a pavement on the curve, is provided at (A) Beginning of the transition curve (B) Centre of the transition curve (C) Beginning of the circular curve (D) Centre of the circular curve

Last Answer : Answer: Option C

Description : The type of joint generally used in cast iron pipes, is (A) Socket and spigot joint (B) Flanged joint (C) Dresser coupling joint (D) All the above

Last Answer : (D) All the above