Corona loss is less when the shape of conductor is:

2 Answers

Answer :

Corona loss is less when the shape of conductor is: circular

Answer :

Circular

Related questions

Description : The corona is considerably affected by which of the following ? (a) Size of the conductor (b) Shape of the conductor (c) Surface condition of the conductor (d) All of the above

Last Answer : (d) All of the above

Description : The corona is considerably affected by which of the following ? (a) Size of the conductor (b) Shape of the conductor (c) Surface condition of the conductor (d) All of the above

Last Answer : (d) All of the above

Description : Solid type cables are considered unreliable beyond 66 kV because (a) insulation may melt due to higher temperature (b) skin effect dominates on the conductor (c) of corona loss between conductor and sheath material (d) there is a danger of breakdown of insulation due to the presence of voids

Last Answer : (d) there is a danger of breakdown of insulation due to the presence of voids

Description : The input impedance of a short circuited loss less transmission line of characteristic impedance 50 Ohm is

Last Answer : Capacitive

Description : An overhead transmission line has a span of 260 m. The weight of the conductor is 0.68 kg/m. The maximum allowable tension in the line is 1550 kg. Maximum sag of the line should be (a) 5.8 m (b) 4.6 m (c) 2.7 m (d) 3.7 m 

Last Answer : Maximum sag = (l^2)/8c So c = T/W c = 1550/0.68 c= 2279.4 Now Maximum sag = (260^2)/8(2279.4) = 3.7 (d)

Description : A 3 layer, total diameter of an ACSR conductor is 5 cm. Find the diameter of each strand?

Last Answer : A 3 layer, total diameter of an ACSR conductor is 5 cm. Find the diameter of each strand? 1 cm

Description : why we use aluminium conductor and not copper in transmission lines ?

Last Answer : Because copper conductor are costlier than aluminium conductor

Description : An electrical discharge ionizing the air around a conductor is called: w) Flux x) Corona y) Ozone z) Field

Last Answer : ANSWER: X -- CORONA

Description : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is

Last Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

Last Answer : Corona is nothing but the ionization of surrounding air around the conductor which produces hissing noise,

Description : Corona loss is minimum in: (1) Monopolar HVDC line (2) Bipolar HVDC line (3) Both in Monopolar& Bipolar HVDC lines (4) EHV AC lines

Last Answer : Corona loss is minimum in: Monopolar HVDC line

Description : The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be   (a) 0.30 kW/ph/km (b) 0.36 kW/ph/km (c) 028 kW/ph/km (d) 0.21 kW/ph/km

Last Answer : The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be 028 kW/ph/km

Description : Corona loss in transmission lines can be reduced by (A) using small diameter conductors (B) using bundled conductors (C) using less spacing between conductors (D) increasing the transmission line voltage

Last Answer : Corona loss in transmission lines can be reduced by using bundled conductors

Description : The corona loss of a 3-phase transmission line is 100 kW at 60 kV/phase and 25 kW at 50 kV/phase. The disruptive critical voltage is (A) 40 kV (B) 43.6 kV (C) 49.6 kV (D) 50 kV

Last Answer : The corona loss of a 3-phase transmission line is 100 kW at 60 kV/phase and 25 kW at 50 kV/phase. The disruptive critical voltage is 40 kV

Description : Corona loss can be reduced by the use of hollow conductors because?

Last Answer : Corona loss can be reduced by the use of hollow conductors because of better ventilation in the conductor.

Description : The corona loss on a particular system at 50 Hz is 1 kw/phase per km. The corona loss on the same system with supply frequency 25 Hz will be?

Last Answer : The corona loss on a particular system at 50 Hz is 1 kw/phase per km. The corona loss on the same system with supply frequency 25 Hz will be 0.667 kW/phase/km.

Description : If the loss tangent is very less, then the material will be a a) Conductor b) Lossless dielectric c) Lossy dielectric d) Insulator

Last Answer : b) Lossless dielectric

Description : Which type of corona generates much less ozone? A) A positive corona  B) A negative corona C) Both positive corona and negative corona generate same amount of ozone D) No ozone is generated by either type of corona

Last Answer : Which type of corona generates much less ozone? A) A positive corona  B) A negative corona C) Both positive corona and negative corona generate same amount of ozone D) No ozone is generated by either type of corona

Description : T.V. transmission cannot cover a very large area because _____ A. The strength of T.V. waves is very limited B. Picture cannot be transmitted clearly after a specific distance C. The shape of the earth is spherical D. The air is not a good conductor of light and sound/waves

Last Answer : ANSWER: C

Description : To prevent damage from lightning, lightning conductors are used on tall structures. The lightning conductor - (1) should be made of a good conductor but can be of any shape (2) should be in the form ... can be of any shape (4) should be made of a good conductor like copper with sharp-pointed edges

Last Answer : (4) should be made of a good conductor like copper with sharppointed edges Explanation: A lightning conductor is made up of a sharp pointed metal (usually copper metal, as it is a very good ... cloud, it will first strike the pointed tip of the lightning conductor and quickly travel to the earth.

Description : T.V. transmission cannot cover a very large area because A. the strength of T.V. waves is very limited B. picture cannot be transmitted clearly after a specific distance C. the shape of the earth is spherical (Answer) D. the air is not a good conductor of light and sound/waves

Last Answer : C. the shape of the earth is spherical (Answer)

Description : To prevent damage from lightning, lightning conductors are used on tall structures. The lightning conductor (1) should be made of a good conductor but can be of any shape (2) should be in the form of ... can be of any shape (4) should be made of a good conductor like copper with sharp-pointed edges

Last Answer : should be made of a good conductor like copper with sharp-pointed edges

Description : Do you think is DC better than AC to transmit energy?

Last Answer : In Long distance DC transmission will be better in cost. It requires more equipments for flexiblity In short distance AC transmission is better in  cost. It is more Flexible

Description : A long transmission line has considerable ……………….. effect. A) series capacitance B) shunt capacitance C) series inductance D) shunt inductance

Last Answer : Shunt Capacitance. 

Description : A single-line-to-ground fault on a overhead transmission line creates (A) voltage sag (B) voltage swell (C) over voltage (D) voltage flicker 

Last Answer : Creates  overvoltage.

Description : For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: (1) 100 Ω (2) 50 Ω (3) 25 Ω (4) 10 Ω

Last Answer : For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: 10 Ω

Description : A 10 km long line has a characteristic impedance of 400 ohms. If line length is 100 km, the characteristic impedance is: (1) 4000 Ω (2) 400 Ω (3) 40 Ω (4) 4 Ω

Last Answer : A 10 km long line has a characteristic impedance of 400 ohms. If line length is 100 km, the characteristic impedance is: 400 Ω

Description : In an AC transmission line difference in phase of voltage at two ends of the line is due to (a) System voltage (b) Insulators (c) Resistance of line (d) Reactance of line

Last Answer : reactance of line

Description : The connected load of a consumer is 2 kW and his maximum demand is 1.5 kW. The load factor of the consumer is (a) 0.375 (b) 0.75 (c) 1.33 (d) None of these  

Last Answer : a

Description : The main consideration for operating transmission line at high voltage is (a) to increase efficiency only. (b) to reduce power loss only. (c) to increase power transmission capability only. (d) All of the above

Last Answer : to reduce power loss: this is because when power is generated, it is generated at a very low voltage but because it is going to be transported over a long distance it is needed to be increase in order to avoid losses on the way such as copper loss and Eddy loss.

Description : Effect of increase in temperature in an overhead transmission line is (a) to increase stress and length both (b) to decrease stress and length both (c) to decrease stress and increase length (d) None of the above 

Last Answer : D

Description : What type of insulator will be used if the direction of the transmission line is to be changed?

Last Answer : Suspension type of insulator will be used if the direction of the transmission line is to be changed.

Description : Why are shunt reactors connected at the receiving end of long transmission line system: (1) To increase the terminal voltage (2) To compensate voltage rise caused by capacitive charging at light load (3) To improve power factor (4) None of these

Last Answer : Why are shunt reactors connected at the receiving end of long transmission line system: To compensate voltage rise caused by capacitive charging at light load

Description : In case of a ‘High Voltage DC’ transmission, how many minimum conductors are required?

Last Answer : In case of a ‘High Voltage DC’ transmission, how many minimum conductors are required? one

Description : Earth wire on EHV overhead transmission line is provided to protect the line against:

Last Answer : Earth wire on EHV overhead transmission line is provided to protect the line against: lightening surge

Description : Consider the following statements: Over head transmission lines are provided with earth wires: 1 . To protect the transmission line from direct lightning strike 2. To protect the transmission line insulation from the indirect lightning strike ... (1) 1 and 3 (2) 1 and 4 (3) 1 only (4) 2 on|y

Last Answer : Consider the following statements: Over head transmission lines are provided with earth wires: 1 . To protect the transmission line from direct lightning strike 2. To protect the transmission line insulation from the indirect lightning ... (1) 1 and 3 (2) 1 and 4 (3) 1 only (4) 2 on|y

Description : To increase power transfer capability of a long transmission line, we should:  (1) Increase line resistance (2) Increase transmission voltage (3) Decrease line reactance (4) Both (2) & (3)

Last Answer : To increase power transfer capability of a long transmission line, we should:  (1) Increase line resistance (2) Increase transmission voltage (3) Decrease line reactance (4) Both (2) & (3)

Description : Transmission of power by a.c. cables is impossible beyond   (a) 500 km (b) 300 km (c) 250 km (d) 45 km 

Last Answer : D

Description : The inductance of single phase two wire power transmission line per km gets doubled when the  (a) Distance between wires is doubled  (b) Distance between the wires is increased four fold  (c) ... the wires is increased as square of the original distance  (d) Radius of the wire is doubled

Last Answer : The inductance of single phase two wire power transmission line per km gets doubled when the Distance between the wires is increased as square of the original distance 

Description : Galloping in transmission line conductors arises generally due to - (A) asymmetrical layer of ice formation (B) vortex phenomenon in light winds (C) heavy weight of line conductors (D) adoption of horizontal conductor

Last Answer : D

Description : The inductance of a power transmission line increases with (A) decrease in line length. (B) increase in conductor diameter. (C) increase in spacing between phase conductors. (D) increase in load current carried by conductors.

Last Answer : The inductance of a power transmission line increases with  increase in spacing between phase conductors.

Description : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Last Answer : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Description : The electric breakdown strength of insulating materials depends on  (A) Nature of applied voltage (B) lmperfection of dielectric material (C) Pressure, temperature and humidity (D) All or these

Last Answer : The electric breakdown strength of insulating materials depends on  (A) Nature of applied voltage (B) lmperfection of dielectric material (C) Pressure, temperature and humidity (D) All or these

Description : The number of insulator discs (each rated 11 kV) required in a suspension type insulator string of 220 kV line is 

Last Answer : The number of insulator discs (each rated 11kV) required in a suspension type insulator string of 220 kV line is 16

Description : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be

Last Answer : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be 0.2 mega ohm

Description : Stability of a transmission line can be increased by

Last Answer : Stability of a transmission line can be increased by Shunt capacitor, Series capacitor

Description : The function of steel wire in ACSR conductors is (A) To take care of surges. (B) To reduce corona. (C) To reduce inductance. (D) To provide additional mechanical strength

Last Answer : The function of steel wire in ACSR conductors is To provide additional mechanical strength

Description : In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Last Answer : In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

Description : For 11kV line the inductance per km per phase will be of the order of:  (A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

Last Answer : For 11kV line the inductance per km per phase will be of the order of: 1 mH

Description : For 11 kV line the capacitance per km per phase will be of the order of:  (A) 1 Farad (B) 0.1 Farad (C) 0.01 Farad (D) 0.01 microF

Last Answer : For 11 kV line the capacitance per km per phase will be of the order of: 0.01 Farad