Why link is provided in neutral of an ac circuit and fuse in phase of ac circuit?

1 Answer

Answer :

A:Link is provided at a Neutral common point in the circuit from which various connection are taken for the individual control circuit and so it is given in a link form to withstand high Amps. But in the case of Fuse in the Phase of AC circuit it is designed such that the fuse rating is calculated for the particular circuit (i.e load) only.So if any malfunction happen the fuse connected in the particular control circuit alone will blow off.

Related questions

Description : Why link is provided in neutral of an ac circuit and fuse in phase of ac circuit?

Last Answer : Link is provided at a Neutral common point in the circuit from which various connections are taken for the individual control circuit and so it is given in a link form to withstand high Amps. ... So if any malfunction happens the fuse connected in the particular control circuit alone will blow off.

Description : Why link is provided in neutral of an ac circuit and fuse in phase of ac circuit?

Last Answer :  Link is provided at a Neutral common point in the circuit from which various connections are taken for the individual control circuit and so it is given in a link form to withstand high Amps.  ... Supply is on than due to open or break Neutral Voltage is increase and equipment may be damage.

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : Which of the listed items will stop a motor due to a reduction in voltage and restart it when the voltage is restored to normal? A. Low voltage protection circuit B. Non-renewable link fuse C. Renewable link fuse D. Low voltage release circuit

Last Answer : Answer: D

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : Explain the meaning of following terms: i) MCB ii) Socket outlet iii) Neutral iv) Fuse-link

Last Answer : i) MCB:  Miniature circuit breaker operates automatically at the time of fault or over load. And it is used for the protection of electrical installation. They are available from 0.5 A to 100 Amps. ... melts automatically at the time of fault or over load. Fuse must be replaced after the fault.

Description : A bus disconnect link is used to isolate _____________. A. one bus bar from another B. the generator circuit breaker from the bus C. different phases from the equalizer connection D. positive and negative buses from the neutral

Last Answer : Answer: B

Description : If an AC generator experiences voltage failure, the cause may be _____________. A. an open in the field circuit B. the brushes shifting out of the neutral plane C. excessive locked-rotor current D. a rotating slip ring

Last Answer : Answer: A

Description : If an electric motor fails to start, you should FIRST check the _____________. A. phase sequence B. ampere load C. fuse or circuit breaker D. line frequency

Last Answer : Answer: C

Description : When testing for blown fuses in a three-phase supply circuit to a motor, you should first ___________________. A. apply the megger across the tops of the line fuses B. apply an ammeter diagonally across ... of the line fuses D. ensure the circuit is de-energized, and then use a continuity tester

Last Answer : Answer: D

Description : You are using a mechanical voltage tester to check the fuses in a three-phase circuit supplying an electric motor. For which of the following reasons must the motor be stopped during the test? A. ... circuit would be indicated by the voltage tester with the circuit energized. D. All of the above.

Last Answer : Answer: B

Description : In an electrical circuit, a fuse is connected (a) in the live wire (b) in the neutral wire (c) in the earth wire (d) anywhere—it makes no difference

Last Answer : Ans:(a)

Description : The fuse in an electric circuit is connected in – (1) series with neutral (2) parallel to live (3) parallel to neutral (4) series with live

Last Answer : (4) series with live Explanation: A fuse wire is a safety wire connected in series with the live wire that has high resistivity and low melting point. Fuses are always connected in ... large current supply or malfunctioning in the electric connections, it melts and breaks the electric circuit.

Description : The fuse in an electric circuit is connected in (1) series with neutral (2) parallel to live (3) parallel to neutral (4) series with live 

Last Answer : series with live

Description : In order to prevent the winch shown in the illustration from turning while troubleshooting the controller circuit, _________________. EL-0102 A. set the dynamic brake by clamping contact 'DB' closed B. set the ... at 'B1' and 'B2' D. open the test link preventing current flow to the armature

Last Answer : Answer: D

Description : In order to determine whether or not 'fuse 2' shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: B

Description : In order to determine whether or not 'Fuse 1', shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: C

Description : The circuit illustrated represents a single phase AC ground detecting system. If a ground occurs on line 'B', which of the lamps will burn the brightest? EL-0008 A. X B. Y C. Both will be equal brightness. D. both will go out.

Last Answer : Answer: A

Description : You are attempting to parallel two AC generators, and the synchroscope pointer is revolving fast in the clockwise direction. This indicates that the frequency of the incoming machine is _____________. A. higher ... at any pointer position D. the same as the bus frequency but out of phase with it

Last Answer : Answer: A

Description : You are attempting to parallel two AC generators, and the synchroscope pointer is revolving in the fast direction. This indicates that the frequency of the incoming machine is _____________. A. higher ... the same as the bus frequency and the circuit breaker may be closed at any pointer position

Last Answer : Answer: A

Description : You are attempting to parallel two AC generators and the synchroscope pointer stops at a position other than 0° prior to closing the circuit breaker. This indicates ___________. A. the frequency of ... be closed after breaker has been reset D. there is an existing cross current between generators

Last Answer : Answer: A

Description : You are attempting to parallel two AC generators and the synchroscope pointer is revolving in the slow direction. This indicates that the frequency of the incoming machine is _____________. A. higher than ... same as the bus frequency, and the circuit breaker may be closed at any pointer position

Last Answer : Answer: B

Description : In the flow of one cycle of single phase AC current past any given point in a circuit, the maximum current peak occurs _____________. A. one time B. two times C. three times D. four times

Last Answer : Answer: B

Description : Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the __________. A. manual position B. bus neutral position C. raise voltage position D. transfer position

Last Answer : Answer: A

Description : Which one of the following applications software’s is used to obtain an accurate root locus for? a) LISP b) MATLAB c) dBase d) Oracle Ans: B 6.Lenz devised a rule to find out direction of a)current induced in a circuit b)electromagneticdifference c)potential difference d)flow of power in fuse

Last Answer : Ans: A

Description : Which of the following precautions should be taken when a blown fuse, rated at 10 amperes, is replaced? A. Short out the fuse before removing it from the circuit. B. Use needle-nose pliers to ... D. Fuses of 10 ampere rating and less are virtually harmless when energized and may be handled freely.

Last Answer : Answer: C

Description : If a voltage tester is being used to check for defective fuses in the circuit, shown in the illustration, which of the readings will indicate that fuse #2 is open? EL-0062 A. C-B full voltage B. A-D full voltage C. A-D no voltage D. C-B no voltage

Last Answer : Answer: C

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : A circuit with a blown fuse would be described as a/an _____________. A. short circuit B. open circuit C. bonded circuit D. grounded circuit

Last Answer : Answer: B

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : If a fuse of correct size and type blows frequently, ________________. A. try the next higher amperage rating B. try the next lower amperage rating C. look for trouble within the circuit D. reduce the applied voltage 10%

Last Answer : Answer: C

Description : An instantaneous-trip-type fuse will _____________. A. open as soon as the load current exceeds its set point B. allow a preset delay between overcurrent and melting C. open a circuit by using a time delay element with a magnetic trip D. reset itself when the overcurrent is corrected

Last Answer : Answer: A

Description : Component 'C' in section 'I' shown in the illustration represent ____________. EL-0093 A. a selectable holding coil arrangement B. a 'fuse blown' indicator circuit C. 'reset' and 'trouble' lamps D. a handset with switch and voice elements

Last Answer : Answer: D

Description : Which of the following conditions is most likely to occur if a single element fuse were used to replace a blown dual element fuse in a motor controller circuit? A. The fuse will blow when the motor ... overheats at high motor loads. C. The motor runs at reduced voltage. D. The motor runs normally.

Last Answer : Answer: A

Description : Before touching a small capacitor connected to a de-energized circuit, or even one that is completely disconnected, you should ____________. A. gently tap the body with a screwdriver B. tag it ... insulated fuse puller D. short circuit the terminals to make sure that the capacitor is discharged

Last Answer : Answer: D

Description : The part of a fuse that melts and opens the circuit is made of _____________. A. copper and antimony B. steel and babbitt C. aluminum or beryllium alloy D. zinc or an alloy of tin and lead

Last Answer : Answer: D

Description : A delayed-action fuse is most frequently used in which of the listed circuits? A. Lighting circuit B. Motor circuit C. Electric heater circuit D. Radar circuit

Last Answer : Answer: B

Description : A circuit breaker differs from a fuse in that a circuit breaker _____________. A. melts and must be replaced B. is enclosed in a tube of insulating material with metal ferrules at each end C. gives no visual indication of having opened the circuit D. trips to break the circuit and may be reset

Last Answer : Answer: D

Description : A circuit breaker and a fuse have a basic similarity in that they both _____________. A. can be reset to energize the circuit B. should open the circuit when overloaded C. will burn out when an over current flow develops D. all of the above

Last Answer : Answer: B

Description : Differentiate between a fuse and a circuit breaker.

Last Answer : Fuse is a low current interrupting device. It is a copper or an aluminium wire. Circuit breaker is a high current interrupting device and it act as a switch under normal operating conditions.

Description : Why is there no fuse in the neutral line ?

Last Answer : There will be no benefit if the fuse is in the neutral line. This means that the problem of the fuse is not removed. Cannot protect over voltage or current. Electronics will not be able to protect the device from damage. That is why the neutral fuse is not given to him.

Description : An electric bulb is connected on a holder. One end of the wire is connected to the phase and the remaining one connected to earth instead of neutral. The bulb will glow or not? If yes then what is the need of neutral?

Last Answer : 1. Yes the bulb will be glow & neutral is return path of Circuit it is originated from distribution transformers star point, form this point only neutral is taken. 2. Then what is the need ... : It gives assurance of reliable centralized earthling as your home may or may not have reliable earthling.

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : As load is added to an AC generator provided with constant field excitation, the prime mover slows down with the effect of ____________. A. lowering frequency and lowering generated ... C. increasing frequency and lowering generated voltage D. lowering frequency and increasing generated voltage

Last Answer : Answer: A

Description : A switchboard, for a AC electrical distribution system, will be provided with which of the following components? A. Frequency meter. B. Ammeter C. Voltmeter D. All of the above

Last Answer : Answer: D

Description : Why shading rings provided in armature core of ac contactor. Why not for dc contactor? 

Last Answer : Because the force developed is not steady in ac therefore contacts will chatter but if shading ring is used force developed becomes steady due to splitting of phases of flux, therefore contacts becomes bounce free and humming sound reduces.  

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : Name any two methods of reducing short circuit current/ By providing neutral reactance.