Why Earth Wire is provided in the overhead transmission lines?

1 Answer

Answer :

Earth wire is provided above the overhead transmission lines for protection against lightning strokes. The ground wire or earth wire protects the phase conductors or line conductors by attracting itself the lightning strokes which in its absence would strike the phase conductors. Also the ground wire reduces the voltage electrostatically or electromagnetically induced in the conductors by the discharge of a neighboring cloud. It also provides the additional protective effect by causing the attenuation of traveling waves set in the lines by acting a short circuit secondary of the line current

Related questions

Description : How standard lightning impulse wave is represented?

Last Answer : Answer: Standard Lighting impulse wave is represented by 1.2/50 micro sec wave

Description : What is meant by voltage surge?

Last Answer : Voltage surge is sudden excessive rise in voltage that may be dangerous to the electrical equipment of an installation. Voltage surge cause damage to insulation of the system. Voltage surges are caused because of lightning, switching on and off the load at high voltages

Description : What is meant by impulse ratio of any lightning arrester?

Last Answer : Impulse ratio of any lightning arrester is the ratio of breakdown voltage of the wave of special duration to breakdown voltage of a 50Hz wave

Description : What is meant by Lightning arrester or surge diverter?

Last Answer : A Surge Diverter is a device that is connected between line and earth, i.e, in parallel with the equipment under protection at the substation. It limits the duration and amplitude of the follow current

Description : What is the difference between the lightning arrester and surge absorber?

Last Answer : Lightning arrester limits the duration and amplitude of the follow current while a surge absorber reduces the steepness of the wave front for a particular surge

Description : What is meant by protective angle? Give its value for reliable operation?

Last Answer : Protective angle is the vertical angle through the ground wire axis and the line passing from the ground wire axis to the outermost phase conductor. Its value for reliable protection is taken equal to 20-30 degrees

Description : Earth wire on EHV overhead transmission line is provided to protect the line against:

Last Answer : Earth wire on EHV overhead transmission line is provided to protect the line against: lightening surge

Description : Most of the high voltage transmission lines in India are (a) underground (b) overhead (c) either of the above (d) none of the above

Last Answer : (b) overhead

Description : The advantage of cables over overhead transmission lines is (a) easy maintenance (b) low cost (c) can be used in congested areas (d) can be used in high voltage circuits

Last Answer : (c) can be used in congested areas

Description : What is the material used for overhead transmission lines?

Last Answer : Answer: ACSR conductors are employed.

Description : Which of the following materials is used for overhead transmission lines ? (a) Steel cored aluminium (b) Galvanised steel (c) Cadmium copper (d) Any of the above

Last Answer : (d) Any of the above

Description : Most of the high voltage transmission lines in India are (a) underground (b) overhead (c) either of the above (d) none of the above

Last Answer : (b) overhead

Description : Why are overhead transmission lines not insulated?

Last Answer : Insulators are useful to help separate electrical conductors when they come into physical contact. Overhead Transmission Lines Are Not Insulated: The overhead transmission line is carrying extreme high voltage and ... a whole lot of thick insulation to absorb the heat produced by such high voltage.

Description : Bundled conductors are mainly used in high voltage overhead transmission lines to (a) Reduce line loss (c) Reduce corona (b) Reduce harmonics (d) Increase strength

Last Answer : Bundled conductors are mainly used in high voltage overhead transmission lines to Reduce corona 

Description : Large cable sizes are formed as individual conductors that may be comprised of several smaller strands to __________. A. obtain the flexibility required for easy handling B. reduce the overall weight of the ... . reduce the number of supports needed for a horizontal overhead run D. all of the above

Last Answer : Answer: A

Description : Consider the following statements: Over head transmission lines are provided with earth wires: 1 . To protect the transmission line from direct lightning strike 2. To protect the transmission line insulation from the indirect lightning strike ... (1) 1 and 3 (2) 1 and 4 (3) 1 only (4) 2 on|y

Last Answer : Consider the following statements: Over head transmission lines are provided with earth wires: 1 . To protect the transmission line from direct lightning strike 2. To protect the transmission line insulation from the indirect lightning ... (1) 1 and 3 (2) 1 and 4 (3) 1 only (4) 2 on|y

Description : . Why are coaxial lines more efficient at microwave frequencies than two-wire transmission lines?

Last Answer : The electromagnetic fields are completely confined

Description : What for series and shunt compensation provided in EHV transmission lines?

Last Answer : Answer: Series capacitance is provided in EHV lines to artificially reduce the series reactance of the line so as to improve stability, voltage regulation and transmission efficiency Shunt compensation ... reduce the line susceptance so as to improve the voltage regulation under light load condition

Description : What can I do about a wall switch for an overhead light if the socket doesn't have a neutral wire and the switch does?

Last Answer : answer:This doesn't make sense. The ground wire is the bare-naked copper wire that's a little thinner than the others. In addition to a ground wire, if any, there must be two regular insulated wires ... though they can be wired to switch neutral. For lights it shouldn't matter. Does any of this fit?

Description : Differentiate between overhead transmission and underground transmission.

Last Answer : Points Overhead line  Underground cable Capital cost  Less More Erecting cost  Less More Time require for completion of work Less More Flexibility More ... Space consumed Space consumed  No space consumed Appearance Not good  Very good 

Description : A single-line-to-ground fault on a overhead transmission line creates (A) voltage sag (B) voltage swell (C) over voltage (D) voltage flicker 

Last Answer : Creates  overvoltage.

Description : Effect of increase in temperature in an overhead transmission line is (a) to increase stress and length both (b) to decrease stress and length both (c) to decrease stress and increase length (d) None of the above 

Last Answer : D

Description : An overhead transmission line has a span of 260 m. The weight of the conductor is 0.68 kg/m. The maximum allowable tension in the line is 1550 kg. Maximum sag of the line should be (a) 5.8 m (b) 4.6 m (c) 2.7 m (d) 3.7 m 

Last Answer : Maximum sag = (l^2)/8c So c = T/W c = 1550/0.68 c= 2279.4 Now Maximum sag = (260^2)/8(2279.4) = 3.7 (d)

Description : Surge impedance of overhead transmission line is normally in the order of (a) 1- 5 ohms (c) 300 - 500 ohms (b) 20 - 30 ohms (d) 300000 - 500000 ohms

Last Answer : Surge impedance of overhead transmission line is normally in the order of 300 - 500 ohms

Description : A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will?

Last Answer : A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will progressively increase from the receiving end to the sending end.

Description : The time taken for a surge to travel a 600 km long overhead transmission line is?

Last Answer : The time taken for a surge to travel a 600 km long overhead transmission line is 0.002s.

Description : An overhead transmission line has a span of 240m between level supports. What is the maximum sag if the conductor weight 727 kg/km and has a breaking strength of 6880 kg? Allow the factor of safety of 2. Neglecting wind and ice loading.

Last Answer : An overhead transmission line has a span of 240m between level supports. 1.52 m is the maximum sag if the conductor weight 727 kg/km and has a breaking strength of 6880 kg? Allow the factor of safety of 2. Neglecting wind and ice loading.

Description : In McCabe-Thiele method, at infinite reflux ratio (A) The overhead product is minimum (B) Both the operating lines coincide with diagonal (C) Both (A) and (B) (D) Neither (A) nor (B)

Last Answer : (A) The overhead product is minimum

Description : In McCabe-Thiele method, at infinite reflux ratio (A) Number of plates is maximum (B) Overhead product is maximum (C) Both the operating lines coincide with the diagram (D) None of these

Last Answer : (C) Both the operating lines coincide with the diagram

Description : Overhead lines generally use (a) copper conductors (b) all aluminium conductors (c) A.C.S.R. conductors (d) none of these

Last Answer : (c) A.C.S.R. conductors

Description : A minimum clearance of 6.3 m to ground is required for overhead lines when operating voltages are :  (A) less than 66 kV (B) lie between 66 kV and 110 kV (C) more than 165 kV (D) lie between 110 kV and 165 kV

Last Answer : A minimum clearance of 6.3 m to ground is required for overhead lines when operating voltages are : lie between 66 kV and 110 kV

Last Answer : Overhead lines for power supply to tramcars are at a minimum height of 10 m.

Description : Why ACSR conductor is used for overhead lines?

Last Answer : It has high tensile strength 

Description : In order to reduce the harmful effects of harmonics on the A.C. side of a high voltage D.C. transmission system ______are provided. (A) synchronous condensers (B) shunt capacitors (C) shunt filters (D) static compensators

Last Answer : Ans: C Xc= 1/ ωc

Description : In a three-phase electrical system, three ground detecting lamps are provided. One lamp goes dark and the others increase in brightness. When the test button is pushed, all lamps have equal illumination. You ... C. there are grounds on the lines with the bright lamps D. this is a normal condition

Last Answer : Answer: A

Description : What are the protections provided for 220 kV lines and bus bars? 

Last Answer : a. Bus bar differential protection. b. Distance protection. c. Over current protection. d. Earth fault protection. 

Description : Why non-return valves are provided in the steam extraction lines?

Last Answer : Non-return valves are provided because when the turbine trips there will be an instant drop in pressure inside the turbine. But there will be steam in feed water heaters, which is at high pressure ... . So non-return valves are provided in steam extraction lines to prevent over speeding of turbine. 

Description : The leakage current in the transmission lines is referred to as the a) Resistance b) Radiation c) Conductance d) Polarisation

Last Answer : Ans: C

Description : What are the different relays that employed for protection of apparatus and transmission lines?

Last Answer : Answer: The relays that are usually employed for protection of transmission lines include • Over current relay • Directional relay • Distance relay • Under Voltage relay • Under-frequency relay • Thermal relay • Differential relay • Phase sequence relays • pilot relays

Description : Why, when birds sit on transmission lines or current wires doesn't get shock?

Last Answer : It's true that if birds touch the single one line (phase or neutral) they don't get electrical shock... if birds touch 2 lines than the circuit is closed and they get electrical shock. so ... is grounded..So that means that human who touch the line closes the circuit between phase and neutral.

Description : Why, when birds sit on transmission lines or current wires doesn't get shock?

Last Answer : A:Its true that if birds touch the single one line (phase or neutral) they don't get electrical shock... if birds touch 2 lines than the circuit is closed and they get electrical shock.. so if a human ... the air. If he is standing on the ground then touching the line (phase) he will get a shock.

Description : The regulation of Short Transmission lines depends up on a) Distance of line b) Frequency c) Power factor d) All

Last Answer : Ans: Power factor

Description : ACSR (Aluminium Conductor Steel Reinforced) are used as (A) over head transmission lines. (B) super conductors. (C) fuse (D) underground cables.

Last Answer : (A) over head transmission lines.

Description : Earth wire or ground wire is made of: a) copper b) aluminium c) iron d) galvanized steel

Last Answer : Ans: D

Description : An electric bulb is connected on a holder. One end of the wire is connected to the phase and the remaining one connected to earth instead of neutral. The bulb will glow or not? If yes then what is the need of neutral?

Last Answer : 1. Yes the bulb will be glow & neutral is return path of Circuit it is originated from distribution transformers star point, form this point only neutral is taken. 2. Then what is the need ... : It gives assurance of reliable centralized earthling as your home may or may not have reliable earthling.

Description : Why earth switches are provided in 220 kV bays?  

Last Answer : When bay CB trips, both end (station and grid) CB will trip. The earth switches are provided because the grid will always be alive so to prevent any shocks to the operator or maintenance personnel who is working on the line or bay due to accidental energizing of the bus.  

Description : It consists of spike tooth cylinder, woven- wire mesh concave and upper casing provided with helical concave. a) Dummy type c) Spike-tooth type b) Hummer type d) Axial flow type

Last Answer : Axial flow type

Description : Copper wires are generally used for electrical power transmission instead of iron wire because (1) copper is cheaper than iron (2) copper is lighter than iron (3) copper is a better conductor of electricity than iron (4) copper can take higher power than iron

Last Answer : (3) copper is a better conductor of electricity than iron Explanation: Copper is generally preferred for electrical power transmission instead of iron because of its high electrical conductivity and low resistivity.

Description : What type of balun (balanced-to-unbalanced) is used in high frequency applications? A. Transformer type balun B. A specially configured coaxial transmission line C. A specially configured parallel-wire line D. A λ/2 transformer balun

Last Answer : B. A specially configured coaxial transmission line

Description : Which of the following is considered the most frequently used transmission line? A. Two-wire open line B. Twin lead C. Rigid coaxial line D. Flexible coaxial line

Last Answer : D. Flexible coaxial line