Description : What line has a typical velocity factor of about 0.8? A. Shielded pair B. Flexible coaxial C. Twin-lead D. Open-wire line
Last Answer : C. Twin-lead
Description : A transmission line consisting of two conductors that have equal resistance per unit length. A. Unbalanced line B. Open-wire line C. Balanced line D. Coaxial line
Last Answer : C. Balanced line
Description : What type of balun (balanced-to-unbalanced) is used in high frequency applications? A. Transformer type balun B. A specially configured coaxial transmission line C. A specially configured parallel-wire line D. A λ/2 transformer balun
Last Answer : B. A specially configured coaxial transmission line
Description : Best choice of transmission line component to couple a coaxial line to a parallel-wire line A. Shorting B. Balun C. Slotted line D. Directional coupler
Last Answer : B. Balun
Description : A single conductor running from the transmitter to the antenna. A. RG-8/U B. Single line wire C. Twin-lead D. MIcrostrip
Last Answer : B. Single line wire
Description : What is the velocity factor for non-foam dielectric 50 or 75 ohm flexible coaxial cable such as RG 8, 11, 58 and 59? A. 2.70 B. 0.66 C. 0.30 D. 0.10
Last Answer : B. 0.66
Description : What is the velocity factor for non-foam dielectric 50 or 75 ohm flexible coaxial cable such as RG 8, 11, 58 and 59? A. 2.70 B. 0.10 C. 0.66 D. 0.30
Last Answer : C. 0.66
Description : Which of the following is not a bounded medium? A. Coaxial line B. Two-wire line C. Waveguide D. Free space
Last Answer : D. Free space
Description : What medium is used by IBM token ring network that operates at either 4 Mbps or 16 Mbps? A. Twisted pair B. Coaxial cable C. Fiber-optic D. Parallel-wire line
Last Answer : A. Twisted pair
Description : To connect coaxial line to a parallel-wire _________ is the best to use. A. directional coupler B. quarter-wave transformer C. balun D. slotted line
Last Answer : C. balun
Description : A coaxial cable has 7dB of reflected power when the input is 5 watts. What is the output of the transmission line? A. 5 watts B. 2.5 watts C. 1.25 watts D. 1 watt
Last Answer : D. 1 watt
Description : What would be the physical length of a tpical coaxial transmission line that is electrically one-quarter wavelength long at 14.1 MHz? A. 20 meters B. 3.51 meters C. 2.33 meters D. 0.25 meter
Last Answer : B. 3.51 meters
Description : Why is the physical length of a coaxial cable transmission line shorter than its electrical length? A. Skin effect is less pronounced in the coaxial cable B. RF energy moves slower along the ... higher in the parallel feed line D. The characteristic impedance is higher in the parallel feed line
Last Answer : B. RF energy moves slower along the coaxial cable
Description : What is the meaning of the term velocity factor of a transmission line? A. The ratio of the characteristic impedance of the line to the terminating impedance B. The index of shielding for coaxial ... The velocity of the wave on the transmission line divided by the velocity of light in a vacuum.
Last Answer : D. The velocity of the wave on the transmission line divided by the velocity of light in a vacuum.
Description : What is the meaning of the term velocity factor of a transmission line? A. The index of shielding for coaxial cable B. The velocity of the wave on the transmission line multiplied by the velocity of ... The velocity of the wave on the transmission line divided by the velocity of light in a vacuum
Last Answer : D. The velocity of the wave on the transmission line divided by the velocity of light in a vacuum
Description : The outer conductor of a coaxial transmission line is always grounded at the A. Input only B. Input and output C. Output only D. Point of high SWR
Last Answer : B. Input and output
Description : . Why are coaxial lines more efficient at microwave frequencies than two-wire transmission lines?
Last Answer : The electromagnetic fields are completely confined
Description : What do you call a cable consisting of twisted pairs of conductors, each separately insulated? A. Microstrip line B. Strip line C. Quad D. Coaxial cable
Last Answer : C. Quad
Description : What is the characteristic impedance of a coaxial line with the following data: inner diameter = 0.2 in., center conductor diameter = 0.06 in., insulation = Teflon. A. 200Ω B. 75Ω C. 50Ω D. 150Ω
Last Answer : C. 50Ω
Description : To couple a coaxial line to parallel line, it is better to use a ______. A. Slotted line B. Quarter-wave transformer C. Directional Coupler D. Balun
Last Answer : D. Balun
Description : Determine the conductance of a two-wire open line with the following parameters: D = 4 in., d = 0.1 in. and ρ = 2.6x108 Ω-m. A. 2.76x10-9 S/m B. 2.76x10-6 S/m C. 2.76x10-12 S/m D. 2.76x10-3 S/m
Last Answer : A. 2.76x10-9 S/m
Description : What is the typical velocity factor of open-wire line? A. 0.9 B. 0.8 C. 0.5 D. 0.7
Last Answer : A. 0.9
Description : If the operating frequency is 450 MHz what length of a pair of conductors is considered to be a transmission line? A. 2.19 ft B. 2.19 m C. 0.219 ft D. 0.219 m
Last Answer : C. 0.219 ft
Description : A pair of current-carrying conductors is not considered a transmission line unless it is at least ___ λ long at the signal frequency. A. 0.1 B. 0.3 C. 0.2 D. 0.4
Last Answer : A. 0.1
Description : Modulation means A. Varying of information B. Utilization of a single transmission channel to carry multiple signals C. Varying of some parameters of a carrier such as its amplitude to transmit information D. Transmit pulses in DC form on a copper wire
Last Answer : C. Varying of some parameters of a carrier such as its amplitude to transmit information
Description : They experimented with light transmission cables through bundle of fibers and lead to the development of flexible fiberscope. ∙ A. Townes, Schawlow and Kao ∙ B. Maiman, Kao and Bockham ∙ C. Maurer, Kapron and Keck ∙ D. Van Heel, Hopkins and Kapany
Last Answer : D. Van Heel, Hopkins and Kapany
Description : They experimented with light transmission cables through bundle of fibers and lead to the development of flexible fiberscope
Last Answer : Van Heel, Hopkins and Kapany
Description : Indian Constitution is - (1) Rigid (2) Flexible (3) Neither rigid nor flexible (4) Partly rigid and partly flexible
Last Answer : (3) Neither rigid nor flexible Explanation: Indian constitution is neither rigid nor flexible.
Description : Government is classified as parliamentary and presidential on the basis of which of the following? (1) Relations between legislature and executive (2) Relations between politician and civil servants (3) Written or unwritten Constitutions (4) Rigid or Flexible Constitutions
Last Answer : (1) Relations between legislature and executive Explanation: Government is classified as parliamentary and presidential on the basis of relations between legislatures and executive.
Description : Thermocol is a spongy, porous, rigid or flexible foamed plastic, obtained by blowing gas/air through molten (A) Saturated polyester (B) Polyurethane (C) Polystyrene (D) Either (B) or (C)
Last Answer : (D) Either (B) or (C)
Description : Spiral spring is quite rigid. a) Yes b) No it is flexible c) It is of moderate rigidity d) Rigidity can’t be determined
Last Answer : b) No it is flexible
Description : Flange coupling is ............ types of coupling. A. Flexible B. Rigid
Last Answer : B. Rigid
Description : Universal coupling is ............ types of coupling. A. Flexible B. Rigid
Last Answer : A. Flexible
Description : The external load per unit length of (A) A pipe laid on, or projecting above the undisturbed ground and covered with fills, is proportional to the square of the external diameter of the pipe ... fills, is proportional to the square of the width of the trench (D) All the above
Last Answer : (D) All the above
Description : Which of the following canal outlets maintains a constant discharge? (A) Non-modular outlet (B) Flexible outlet (C) Rigid module (D) None of the above
Last Answer : Answer: Option C
Description : Cement grouted pavement is classified as (A) Rigid pavement (B) Semi-rigid pavement (C) Flexible pavement (D) None of these
Last Answer : B
Description : When describing a removable partial denture, the minor connector refers to:** A. Rigid components anterior to the premolar teeth B. Flexible components, in contrast to rigid major connectors ... components to the major connector D. The components of the denture base which provides reciprocation
Last Answer : C. Smaller connectors which connect denture components to the major connector
Description : Spiral spring is quite rigid. (a) Yes (b) No it is flexible (c) It is of moderate rigidity (d) Rigidity can’t be determined
Last Answer : (b) No it is flexible
Description : Discuss the causes of failure in flexible and rigid pavement.
Last Answer : Causes of failure in flexible pavement: The following are the causes of failure in flexible pavement: 1) Ineffective road surface drainage system such as, (i) inadequate cross slope of the ... joints or even non-uniform settlement of the pavement slabs resulting in deterioration in riding quality.
Description : To couple a coaxial line to a parallel wire line, it is best to use a: (1) A slotted line (2) Balun (3) Directional coupler (4) Quarter wave line transformer
Last Answer : To couple a coaxial line to a parallel wire line, it is best to use a: Balun.
Description : ____ system transmits frequency-division-multiplexed voice band signals over a coaxial cable for distances up to 4000 miles. A. T carrier B. X carrier C. L carrier D. F carrier
Last Answer : C. L carrier
Description : An RG-11/U foam coaxial cable has a maximum voltage standing wave of 52 V and a minimum voltage of 17 V. Find the value of the resistive load. A. 24.59Ω B. Either A or C C. 228.75Ω D. Neither A nor C
Last Answer : B. Either A or C
Description : What is the time delay introduced by a 75-ft coaxial cable with a dielectric constant of 2.3? A. 1.54 ns B. 11.5 ns C. 115.6 ns D. 1156 ns
Last Answer : C. 115.6 ns
Description : What is the velocity factor of coaxial cable with a characteristic impedance of 50Ω and capacitance of 30pF/ft and inductance of 75 nH/ft? A. 0.58 B.0.68 C. 0.98 D. 0.81
Last Answer : B.0.68
Description : What is the typical velocity factor of coaxial cables? A. 0.6 to 0.8 B. 0.3 to 0.5 C. 0.5 to 0.9 D. 0.4 to 0.6
Last Answer : A. 0.6 to 0.8
Description : Which coaxial connector is a more complex and expensive but do a better job in maintaining the electrical characteristics of the cable through the interconnections? A. N-type connector B. F-type connector C.BNC D. PL-259
Last Answer : A. N-type connector
Description : Which coaxial cable connector is least expensive and is widely used for TV sets,VCRs and cable TV? A. N-type connector B. F-type connector C. BNC D. PL-259
Last Answer : B. F-type connector
Description : Which of the following coaxial cable connectors is called the UHF connector? A. PL-259 B. BNC C. N-type connector D. F connector
Last Answer : A. PL-259
Description : What material is most often used for the outer covering of coaxial cables? A. PVC B. Teflon C. PE D. Polystyrene
Last Answer : A. PVC
Description : Coaxial lines are used on those systems operating _______. A. Below 2 GHz B. At 300 MHz C. Above 10KHz D. Above 10GHz
Last Answer : A. Below 2 GHz