Across-the-line starters are used with AC motors to provide _____________. A. reduced starting current B. regulated starting current C. high starting torque D. controlled starting acceleration

1 Answer

Answer :

Answer: C

Related questions

Description : The function of the autotransformers used with the starters of large AC motors is to provide _____________. A. increased voltage for starting B. increased torque for starting C. reduced voltage for starting D. speed control

Last Answer : Answer: C

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A

Description : An across-the-line starter is typically used for which of the following applications? A. Reduced-current starting of large motors B. Low torque starting of small motors C. Low resistance starting of DC motors D. Full-voltage starting of motors

Last Answer : Answer: D

Description : Reduced voltage applied to a motor during the starting period will _____________. A. result in decreased acceleration time only B. lower the starting current and increase accelerating time C. cause a greater starting torque D. increase the starting current and pump capacity

Last Answer : Answer: B

Description : Most three-phase induction motors of five horsepower or less, are started by _____________. A. autotransformer starters B. resistor starters C. across-the-line starters D. reactor starters

Last Answer : Answer: C

Description : Most three-phase induction motors used for driving engine room auxiliaries are started by _____________. A. resistor starters B. across-the-line starters C. impedance starters D. reactor starters

Last Answer : Answer: B

Description : Low horsepower, polyphase, induction motors can be started with full voltage by means of _____________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : What is the function of the interpoles installed in DC motors? A. To provide greater torque by strengthening the main field. B. To provide sparkless commutation without having to shift the brushes. C. To limit the production of counter-electromotive force. D. To limit the starting surge current.

Last Answer : Answer: B

Description : In general, polyphase induction motors can be started on full line voltage by means of ______________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : An across-the-line starter provides ___________________. A. maximum torque B. slow starting power C. high speed D. reduced voltage

Last Answer : Answer: A

Description : An advantage of DC motors over AC motors is that they _____________. A. are less expensive B. require less maintenance C. can be started across the line D. offer a more effective means of controlling speed

Last Answer : Answer: D

Description : An operating characteristic appearing on the name plates of shipboard AC motors is _____________. A. the type of winding B. input kilowatts C. temperature rise D. locked rotor torque

Last Answer : Answer: C

Description : The function of amortisseur, or damper windings in a synchronous motor is to _____________. A. eliminate slippage B. provide excitation C. provide starting torque D. increase efficiency

Last Answer : Answer: C

Description : The function of damper windings in a synchronous motor is to _____________. A. eliminate slippage B. provide excitation C. provide starting torque D. increase efficiency

Last Answer : Answer: C

Description : Which of the following operating characteristics for DC motors is considered to give high starting torque? A. series B. shunt C. cumulative-compound D. differential-compound

Last Answer : Answer: A

Description : Why do we use capacitor-start induction motors in applications requiring high starting torque in preference to repulsion induction motors?

Last Answer : Capacitors are easily available, cheaper and reliable. Repulsion-induction motors posses a special commutator and brushes that require maintenance. Most manufacturers have stopped making them.

Description : Why do we use capacitor-start induction motors in applications requiring high starting torque in preference to repulsion induction motors?

Last Answer : Ans : Capacitors are easily available, cheaper and reliable. Repulsion-induction motors posses a special commutator and brushes that require maintenance. Most manufacturers have stopped making them.

Description : Universal motors will operate on AC or DC current, and are generally found in _____________. A. portable tools B. large pump motors C. turbo electric main motors D. forced draft fans

Last Answer : Answer: A

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : Which of the following is a characteristic of fractional horsepower repulsion start motors? A. They start with a rotating stator field. B. The short circuiting ring is removed from the commutator while ... brushes are removed from the commutator while starting. D. They have a low starting torque.

Last Answer : Answer: B

Description : If an induction motor were to be operated at 90% rated voltage, _____________. A. there would be an increase in starting torque B. starting current would increase slightly C. synchronous speed would decrease slightly D. the slip would increase

Last Answer : Answer: D

Description : The output voltage of a three-phase alternator is regulated by the _____________. A. AC voltage to the armature B. AC voltage to the field C. DC voltage to the armature D. DC voltage to the field

Last Answer : Answer: D

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : Which of the listed types of motor controllers and starters is illustrated? EL-0080 A. Across-the-line B. Primary-resistor C. Autotransformer D. Part-winding

Last Answer : Answer: C

Description : As shown in the illustration, which of the listed types of motor controllers and starters is indicated? EL-0012 A. Across-the-line B. Capacitor C. Autotransformer D. Part-winding

Last Answer : Answer: C

Description : An advantage of DC motors over AC motors is that they _____________. A. are less expensive B. require less maintenance C. offer infinite speed variation D. all of the above

Last Answer : Answer: C

Description : The most common source of excitation for synchronous motors is a/an _____________. A. low voltage battery B. motor attenuator set C. DC exciter generator D. AC supply

Last Answer : Answer: C

Description : A loud buzzing noise in an AC controller is probably caused by _____________. A. poor contact with the overload relay B. an incorrectly sized heater C. a broken shading coil D. abnormal starting current

Last Answer : Answer: C

Description : Reduction in the capacitance of a capacitor-start motor, results in reduced (A) Noise. (B) Speed. (C) Starting torque. (D) Armature reaction.

Last Answer : Ans: C Reduction in the capacitance reduces starting voltage, which results in reduced starting torque.

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : Excessive heat in an operating motor controller can result from _____________. A. a closed starter contact B. loose connections C. missing arc chutes D. low motor starting torque

Last Answer : Answer: B

Description : Amortisseur windings are installed in a synchronous motor to _____________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : The purpose of DC generator brushes is to _____________. A. neutralize armature reaction B. conduct electric current to an outside circuit C. convert DC current to AC current D. provide excitation to a DC generator

Last Answer : Answer: B

Description : The purpose of a cage rotor winding placed on the rotor of a synchronous motor is to _____________. A. provide excitation to the DC field B. start the machine as an induction motor C. contribute extra torque at synchronous speed D. prevent the machine from falling out of step

Last Answer : Answer: B

Description : As compared to shunt and compound DC motors, the series DC motor will have the highest torque because of its comparatively ____________ at the start. (A) Lower armature resistance. (B) Stronger series field. (C) Fewer series turns. (D) Larger armature current.

Last Answer : (D) Larger armature current.

Description : What are the types starters used for starting of induction motor?

Last Answer : a. Direct on line starter (air break) mechanically. b. Direct on line starter (air break or oil immersed) electrically. c. Star delta starter. d. Slipring motor starter. e. Auto transformer starter.

Description : A damper winding is designed as part of a synchronous motor to ____________. A. increase efficiency B. provide starting torque C. provide excitation D. eliminate slippage

Last Answer : Answer: B

Description : The frequency of an AC generator is controlled by the _____________. A. rheostat B. governor C. exciter D. capacitor

Last Answer : Answer: B

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the _____________. A. voltage regulators B. field rheostats C. reverse power relays D. prime mover governors

Last Answer : Answer: D

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. keep the lube oil warm for quick starting B. prevent moisture from condensing in the ... is shutdown C. prevent the windings from becoming brittle D. prevent acidic pitting of the slip rings

Last Answer : Answer: B

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. prevent the windings from becoming brittle B. prevent moisture from condensing in the windings during ... C. prevent acidic pitting of the slip rings D. keep the lube oil warm for quick starting

Last Answer : Answer: B

Description : A double squirrel-cage motor is designed to have __________. A. low starting torque B. low starting current C. high starting voltage D. low starting resistance

Last Answer : Answer: B

Description : Which motor has high Starting Torque and Staring current DC motor, Induction motor or Synchronous motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Which Motor Has High Starting Torque And Staring Current Dc Motor, Induction Motor Or Synchronous Motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Which ofthe following materials is used in the manufacture of resistance grids to be used in the starters of large motors ? (a) Copper (b) Aluminium (c) Steel (d) Cast-iron

Last Answer : (d) Cast-iron

Last Answer : Starters are used with D.C. motors because to restrict armature current as there is no back e.m.f. while starting.