What are the types starters used for starting of induction motor?

1 Answer

Answer :

a. Direct on line starter (air break) mechanically.
b. Direct on line starter (air break or oil immersed)
electrically.
c. Star delta starter.
d. Slipring motor starter.
e. Auto transformer starter.

Related questions

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : State starters used for i) 3-Ph squirrel cage induction motor (3HP) ii) D.C. motor 

Last Answer : Name the starters used for following motors : i) 3 H.P. 3-Ph squirrel cage I.M: i) DOL starter OR ii) Star-Delta Starter OR ii) Auto transformer starter OR iii) Soft start starter.  ii) D.C Shunt Motor : 1) Armature resistance starter (Three Point Starter) OR 2) Four Point Starter 

Description : Which of the listed types of motor controllers and starters is illustrated? EL-0080 A. Across-the-line B. Primary-resistor C. Autotransformer D. Part-winding

Last Answer : Answer: C

Description : As shown in the illustration, which of the listed types of motor controllers and starters is indicated? EL-0012 A. Across-the-line B. Capacitor C. Autotransformer D. Part-winding

Last Answer : Answer: C

Description : Most three-phase induction motors of five horsepower or less, are started by _____________. A. autotransformer starters B. resistor starters C. across-the-line starters D. reactor starters

Last Answer : Answer: C

Description : Most three-phase induction motors used for driving engine room auxiliaries are started by _____________. A. resistor starters B. across-the-line starters C. impedance starters D. reactor starters

Last Answer : Answer: B

Description : In general, polyphase induction motors can be started on full line voltage by means of ______________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : Low horsepower, polyphase, induction motors can be started with full voltage by means of _____________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : The function of the autotransformers used with the starters of large AC motors is to provide _____________. A. increased voltage for starting B. increased torque for starting C. reduced voltage for starting D. speed control

Last Answer : Answer: C

Description : Across-the-line starters are used with AC motors to provide _____________. A. reduced starting current B. regulated starting current C. high starting torque D. controlled starting acceleration

Last Answer : Answer: C

Description : Squirrel cage induction motor has a) Zero starting torque b) Very small starting torque c) Medium starting torque d) Very high starting torque

Last Answer : Ans: B

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : A single-phase induction motor starts, comes up to about 75% rated speed, slows down to a lower speed, and accelerates again. The problem is most likely in the ____________. A. starting winding B. running winding C. starting capacitor D. running centrifugal switch

Last Answer : Answer: B

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : Which of the following problems will most likely occur if the starting winding of a split-phase induction motor failed to cutout once the motor was in continuous operation? A. The motor will overspeed. B. The ... reduced speed. C. A time delay will stop the motor. D. The winding will burn out.

Last Answer : Answer: D

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : If an induction motor were to be operated at 90% rated voltage, _____________. A. there would be an increase in starting torque B. starting current would increase slightly C. synchronous speed would decrease slightly D. the slip would increase

Last Answer : Answer: D

Description : A characteristic of an induction motor with a low resistance rotor winding is _____________. A. high starting voltage B. high starting current C. high slippage D. low starting voltage

Last Answer : Answer: B

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : In a 15 HP induction-type motor with a cage rotor, the current required at standstill to produce starting torque is approximately ____________. A. half the full load current B. equal to the full load current C. five times the full load current D. ten to twenty times the full load current

Last Answer : Answer: C

Description : Which of the following statements is true concerning a polyphase synchronous propulsion motor? A. The motor is started as an induction motor. B. Resistance is gradually added to the rotor circuit. C. ... is held below the rated current. D. The field winding is energized for starting purposes only.

Last Answer : Answer: A

Description : Disadvantages of Star-Delta Starting of Induction motor?

Last Answer : In Star-Delta starting induction motor stator is connected in star connection for starting after picking up speed it is connected to delta connection. When induction motor is connected in star connection ... . This also results in reduced starting torque (1/3 times compared to delta connection).

Description : Which motor has high Starting Torque and Staring current DC motor, Induction motor or Synchronous motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Which Motor Has High Starting Torque And Staring Current Dc Motor, Induction Motor Or Synchronous Motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Why shaded-pole single phase induction motor does not need any special starting technique like capacitors and auxiliary winding etc.

Last Answer : Because it is inherently self started motor. The construction of the poles is such that they give a sweep to the magnetic flux and motor starts rotating.

Description : Why is the starting torque of a capacitor start induction motor high?

Last Answer : Ans: The capacitor C in the starting winding is so chosen that Is leads Im by 75 degree. Since the starting torque is directly proportional to Sin Ф, and it is quite high in capacitor-start induction motor.

Description : Why is the starting torque of a resistance split-phase induction motor not high?

Last Answer : The starting torque is given as, Ts = K Im Is Sin Ф Where K = constant whose magnitude depends upon the design of the motor (i) The angle between Is and Im is small ... Im are not equal in magnitude, the rotating magnetic field is not uniform and the starting torque produced is small.

Description : How the starting winding produce rotation in a single phase resistance start induction motor?

Last Answer : The starting winding is highly resistive and the main winding is inductive. So the phase difference between the two currents becomes nearly 90 degree and hence the motor start as two phase motor.

Description : What is the function of centrifugal starting switch in a single-phase induction motor?

Last Answer : Ans: The centrifugal switch is connected in series with the starting winding. The primary function of the centrifugal switch is to produce rotating flux in conjunction with main winding at the time of ... has no function to perform and is removed from the circuit by a centrifugally operated switch.

Description : What are methods available for making single phase induction motor a self starting?

Last Answer : By slitting the single phase, by providing shading coil in the poles.

Description : Why single phase induction motor is not a self starting one?

Last Answer : When motor fed supply from single phase, its stator winding produces an alternating flux, which doesn’t develop any torque.

Description : why the three phase induction motor draws heavy current at starting?

Last Answer : At the time of starting, the rotor speed is zero hence slip is 1, the emf induced in rotor winding is very high. Hence rotor current is also very high. The starting current is 5 to 7 times more than its full load current.

Description : Mention the methods for starting an induction motor?

Last Answer :  The different methods of starting an induction motor  DOL:direct online starter  Star delta starter  Auto transformer starter  Resistance starter  Series reactor starter

Description : What are the types of starters?

Last Answer : Direct on line Autotransformer Star delta Rotor resistance starter Soft starter or Electronic starter

Description : What types of slots are preferred for the induction motor?

Last Answer : Semi enclosed slots are preferred for induction motor. It results in less air gap contraction factor giving a small value of magnetizing currents, low tooth pulsation loss and much quieter operation(less noise)

Description : What are the different types of stator winding in induction motor?

Last Answer : The different types of stator windings are mush winding, lap winding and wave winding.

Description : Mention different types of speed control of slip ring induction motor?

Last Answer : a) By changing supply frequency b) By changing the number of stator poles c) By rotor rheostat control d) By operating two motors in cascade

Description : State the types of Induction motor ?

Last Answer : 1) Squirrel cage Induction motor 2) Wound or slip ring Induction motor.

Description : Difference between a four point starter and three point starters?

Last Answer : The shunt connection in four point starter is provided separately from the line where as in three point starter it is connected with line which is the drawback in three point starter

Description : Develop the control circuit for star-delta starter used for starting a 3 ∅ induction motor.

Last Answer : Control Circuit for Star-Delta Starter: 1) Automatic Star-Delta Starter: OR 2) Semi- automatic Star-Delta Starter:

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The ... maximum torque is  (A) 13.48% (B) 16.42% (C) 18.92% (D) 26.79%

Last Answer : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The value of slip for maximum torque is 26.79%

Description : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be  A) 40 Nm B) 60 Nm C) 90 Nm D) 120 Nm

Last Answer : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be 40 Nm

Description : In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.

Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Description : Starting torque can be obtained in the case of a single phase induction motor with identical main and auxiliary windings by connecting:  (1) A capacitor across the mains (2) A capacitor in ... with the auxiliary winding (4) Equal value capacitors in series with the main and the auxiliary windings

Last Answer : Starting torque can be obtained in the case of a single phase induction motor with identical main and auxiliary windings by connecting:  A capacitor is series with the auxiliary winding.

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.