Prior to taking a resistance reading with a volt-ohm-milliammeter, the 'zero' setting must be adjusted. After clipping the two leads together, you find the adjustment knob will not return the pointer to 'zero'. This is most likely an indication of ______  A. an improper resistance range setting B. weak batteries C. a faulty zero ohms knob D. a faulty meter movement

1 Answer

Answer :

Answer: B

Related questions

Description : You are calibrating a multimeter using internal batteries to supply power for resistance measurements. However, you are unable to adjust the pointer to 'zero' using the adjustment knob. Therefore, you should ... change scales to the R X 100 scale and adjust using the 'zero ohms' adjusting knob

Last Answer : Answer: A

Description : When using a multimeter for resistance measurements, it should be calibrated by clipping the loose ends of the leads together and _____________. A. setting the instrument pointer at 'zero' ohms B. ... the plus and minus terminals D. using a special purpose resistance measuring instrument (a bridge)

Last Answer : Answer: A

Description : When used for taking resistance measurements, a volt-ohm-milliammeter is normally powered by _____________. A. a hand cranked generator B. internal storage batteries C. the current in the circuit being tested D. a step down transformer

Last Answer : Answer: B

Description : Prior to using an analog type ohmmeter, the leads are purposely shorted together. Which of the following actions should be taken if, when adjusting to 'zero' ohms, the indicating needle can not be ... be added to each final reading. D. The test reading should be subtracted from each final reading.

Last Answer : Answer: B

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointer to mid-scale B. short the test leads and calibrate the meter reading to 'zero' C. change the meter's batteries D. center the meter's pointer at infinity

Last Answer : Answer: B

Description : Before using a volt-ohmmeter to measure resistance readings, you should _____________. A. replace all batteries B. test the insulation resistance of the leads C. make sure the test leads do not touch D. hold the leads together and 'zero' the meter

Last Answer : Answer: D

Description : Which of the listed statements is correct when using an analog multimeter as an ohmmeter? A. The pointer should be adjusted to zero each time a new resistance range is selected. B. The ... C. Ohmmeters are not sufficiently sized to measure conductor insulation resistance. D. All of the above.

Last Answer : Answer: D

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointers to mid-scale B. change the meter's batteries C. center the meter's pointer at infinity D. short the test leads and calibrate the meter

Last Answer : Answer: D

Description : A switchboard ammeter indicates a reading slightly above 'zero' when the leads are disconnected, this is caused by _____________. A. mechanical misalignment of the meter pointer B. a poor ground for the meter case C. static electricity in the air D. capacitors inside the meter storing charges

Last Answer : Answer: A

Description : Which of the following statements represents the correct method of connecting the shunt of an ammeter prior to taking a reading? A. In series with the load and in series with the meter movement. B. In ... with the meter movement. D. In parallel with the load and in parallel with the meter movement.

Last Answer : Answer: B

Description : A capacitor is to be tested with a megohmmeter. If the meter is connected to a shorted capacitor, the meter pointer should _____________. A. immediately swing to the maximum resistance value ... and gradually decrease D. swing to zero then gradually increase with slight pointer movements down scale

Last Answer : Answer: B

Description : A capacitor can be tested using a megohmmeter or an ohmmeter. If the meter is connected to a shorted capacitor, the meter pointer should _____________. A. immediately swing to the maximum resistance ... deflect to and remain at zero D. immediately swing to a high reading and then gradually decrease

Last Answer : Answer: C

Description : Errors due to frictions of the meter movement, incorrect spring tension, improper calibration or faulty instruments:

Last Answer : instrument errors

Description : If reading AC current with the illustrated device and unsure of the range as a precaution , the first step should be to _________. EL-0047 A. secure power and test for voltage B. disconnect the ... resistance and use Ohm's law to calculate current D. unable to safely measure current with the device

Last Answer : Answer: A

Description : A milliammeter, with a full scale deflection reading of 100 milliamps, is known to have an accuracy of + or - 2%. A meter reading of 10 milliamps would indicate a line current of between _____________. A. 9.8 ... 9.8 and 10.2 milliamperes C. 8.0 and 12.0 milliamperes D. 8.0 and 10.0 milliamperes

Last Answer : Answer: B

Description : An ammeter reads slightly above 'zero' when its leads are disconnected, this is a result of ___________. A. mechanical misalignment of the meter pointer B. a poor ground for the meter case C. static electricity in the air D. resistors inside the meter storing charges

Last Answer : Answer: A

Description : When troubleshooting most electronic circuits, 'loading effect' can be minimized by using a voltmeter with a/an ___________________. A. input impedance much greater than the impedance across which the voltage ... sensitivity of less than 1000 ohms/volt D. sensitivity of more than 1000 volts/ohm

Last Answer : Answer: A

Description : The reading at 'X' while on the R X 100 meter scale illustrated would be ______. EL-0047 A. 8 ohms B. 150 ohms C. 800 ohms D. 80,000 ohms

Last Answer : Answer: C

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : When a megohmmeter is being used on a alternating current machine, the meter pointer will dip toward 'zero' and then gradually rise to the true resistance value if the motor insulation is _____________. A. grounded B. good C. shorted D. dirty

Last Answer : Answer: B

Description : When a megohmmeter is being used to test insulation resistance, current leakage along the surface of the insulation is indicated by the megohmmeter pointer _____________. A. fluctuating around a ... slightly downscale as voltage is applied D. continually rising as the test voltage is applied

Last Answer : Answer: C

Description : Which of the following conditions indicates a short circuited capacitor when checking its condition with an ohmmeter? A. The capacitor shows charging, but the final resistance reading is appreciably less ... moves quickly to the low resistance side of the scale, then slowly recedes toward infinity.

Last Answer : Answer: B

Description : When a megohmmeter is being used to test insulation resistance, current leakage along the surface of the insulation is indicated by the megohmmeter's pointer _____________. A. dipping toward ... kicking slightly down scale as voltage is applied D. fluctuating around a constant resistance reading

Last Answer : Answer: C

Description : Accurate measurement of deflection angles with a transit not properly adjusted may be made by (A) Setting the Vernier A at zero at back station and then plunging the telescope (B) Setting the ... back sights one with the telescope normal and the other with telescope inverted (D) None of these

Last Answer : (C) Taking two back sights one with the telescope normal and the other with telescope inverted

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : The unit of electrical resistance is the _____________. A. ampere B. volt C. watt D. ohm

Last Answer : Answer: D

Description : With both ends of a three conductor cable disconnected and arranged without the conductors touching each other, an ohmmeter reading of 'zero' ohms between the ends of one conductor would indicate _____________. A. continuity B. a partial ground C. the resistance is infinite D. a short circuit

Last Answer : Answer: A

Description : If PN junction is forward biased its resistance is (a) Zero (b) Infinity (c) A few ohm (d) A few kilo ohms

Last Answer : c) A few ohm

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : A coil is wound with 400 feet of No. 16 tinned copper wire and connected to a 12 volt battery. What is the current if the resistance per 1000 feet of No. 16 tinned copper wire is 4.26 ohms? A. 4.8 amps B. 7.06 amps C. 10.65 amps D. 11.27 amps

Last Answer : Answer: B

Description : A coil is wound with 200 feet of No. 16 tinned copper wire and connected to a 12 volt battery. What is the current if the resistance per 1000 feet of No. 16 tinned copper wire is 4.26 ohms? A. 1.14 amps B. 7.04 amps C. 10.22 amps D. 14.08 amps

Last Answer : Answer: D

Description : What is the total resistance of the electrical circuit illustrated if the resistance of R1 is 2 ohms, R2 is 4 ohms, and R3 is 4 ohms with a 6 volt battery? EL-0021 A. 0.01 ohms B. 0.10 ohms C. 1.00 ohms D. 10.00 ohms

Last Answer : Answer: C

Description : What is the total current in the illustrated circuit with a 6 volt battery if the resistance of R1 is 2 ohms, R2 is 4 ohms, and R3 is 4 ohms? EL-0021 A. 0.6 amp B. 1 amp C. 4 amps D. 6 amps

Last Answer : Answer: D

Description : A lead line or sounding line (A) Is stretched thoroughly when wet before it is graduated (B) Should be soaked in water for about one hour prior to taking soundings (C) Is adjusted at regular interval (D) All the above

Last Answer : (D) All the above

Description : If the pointer on a megger fails to return to 'zero' when not being used, the _____________. A. megger is out of calibration B. megger is operating normally C. hairsprings are burned out D. pointer probably stuck in that position

Last Answer : Answer: B

Description : If the pointer fails to return to zero when a megger is disconnected, the _____________. A. pointer is stuck B. hair springs are burned out C. megger is out of calibration D. megger is operating normally

Last Answer : Answer: D

Description : On the meter scale illustrated, while using the R X 100 scale, the reading at 'Z' is___________. EL-0047 A. 3,000 ohms B. 30,000 ohms C. 300,000 ohms D. 3,000,000 ohms

Last Answer : Answer: A

Description : On the meter scale illustrated, while using the R X 1 scale, the reading at 'E' will be ____________. EL-0047 A. 2.0 ohms B. 20 ohms C. 200 ohms D. none of the above

Last Answer : Answer: A

Description : On the meter scale illustrated, while using the R X 1 scale, the reading at 'F' will be ____________. EL-0047 A. 1.8 ohms B. 6.0 ohms C. 9.4 ohms D. 0.6 ohms

Last Answer : Answer: D

Description : On the meter scale illustrated, while using the R X 1 scale, the reading at 'Z' will be ____________. EL-0047 A. 30 ohms B. 72 ohms C. 720 ohms D. 7.2 Kohms

Last Answer : Answer: A

Description : On the meter scale illustrated, while using the R X 100 scale, the reading at 'F' will be ____________. EL-0047 A. 60 ohms B. 40 ohms C. 30 ohms D. 3 kohms

Last Answer : Answer: A

Description : On the meter scale illustrated, while using the R X 100 scale, the reading at 'B' will be ____________. EL-0047 A. 70 ohms B. 35 ohms C. 700 ohms D. 7 kohms

Last Answer : Answer: D

Description : On the meter scale illustrated, while using the R X 100 scale, the reading at 'C' will be ____________. EL-0047 A. 13 ohms B. 130 ohms C. 1.3 kohms D. 13 kohms

Last Answer : Answer: C

Description : On the meter scale illustrated, while using the R X 100 scale, the reading at 'D' will be ____________. EL-0047 A. 3.6 ohms B. 36 ohms C. 193 ohms D. 360 ohms

Last Answer : Answer: D

Description : On the meter scale illustrated, while using the R X 100 scale, the reading at 'A' will be ____________. EL-0047 A. 2,000 ohms B. 20 Kohms C. 200 Kohms D. 3 Megohms

Last Answer : Answer: B