When the control handle is in the 'off' position, the solenoid actuated brake of the electric winch is _________. A. de-energized and the brake is released B. energized and the brake is released C. energized and the brake is set by a spring D. de-energized and the brake is set by a spring

1 Answer

Answer :

Answer: D

Related questions

Description : Which of the following conditions will occur if the solenoid coil burns out on a cargo winch with an electrical brake? A. The brake will be set by spring force. B. The motor will overspeed and burn ... the cargo boom will fall. D. Nothing will happen; the winch will continue to operate as usual.

Last Answer : Answer: A

Description : Which component is responsible for energizing solenoid 'B1-B2' and releasing the brake for the winch motor shown in the illustration? EL-0102 A. Contactor '3M' B. A spring not shown in the schematic diagram C. Resistor 'B2-R1' D. Relay 'FR-B.O.'

Last Answer : Answer: A

Description : In order to prevent the winch shown in the illustration from turning while troubleshooting the controller circuit, _________________. EL-0102 A. set the dynamic brake by clamping contact 'DB' closed B. set the ... at 'B1' and 'B2' D. open the test link preventing current flow to the armature

Last Answer : Answer: D

Description : The purpose of resistor bank 'R1-R5' in the winch circuit shown in the illustration is to ______________. EL-0102 A. limit armature current in lower and 'series field' current in hoist to ... required speeds D. regulate the strength of the brake solenoid 'B1-B2' in both directions of operation

Last Answer : Answer: C

Description : In the event of a power failure during cargo loading operations, the movement of an electric powered cargo winch will be stopped by ____________. A. a manual override switch B. the weight of the load on the boom C. a spring set brake D. a hand operated band brake

Last Answer : Answer: C

Description : When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'

Last Answer : Answer: C

Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : The full torque electric brake on an electric cargo winch functions to _____________. A. act as a backup brake in the event the mechanical brake should fail B. automatically hold the load ... automatically govern the lowering speed of the load D. automatically govern the hoisting speed of the load

Last Answer : Answer: B

Description : When the operating handle is in the 'off' position, which master switch contacts for the winch shown in the illustration are closed? EL-0102 A. 'MS-DB & OL' B. 'MS-3, 5, 6, 7, & 8' C. 'MS-LVa & OL' D. 'MS-3, 7 & Reset'

Last Answer : Answer: D

Description : As shown in the illustration, once the "LV" relay is energized for operation, what contacts must remain closed to maintain the "LV" relay energized when the control lever is moved away from the "off" or "stop" ... . B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : The purpose of the 'heater resistors' for the winch circuit shown in the illustration is to _______________. EL-0102 A. limit the current in the heater circuit B. dispel moisture in the ' ... panel C. keep the winch brake housing below the dew point D. maintain winch motor operating temperature

Last Answer : Answer: B

Description : In the illustration, the tan and white wires are connected to the solenoid valve. The solinoid valve is_________. EL-0043 A. in the liquid line before the TXV B. energized and open whenever the unit ... so the unit must be modified before using aboard ship D. the water inlet for the ice maker

Last Answer : Answer: D

Description : In the illustration, the tan and white wires are connected to the solenoid valve. The solenoid valve is_________. EL-0042 A. in the liquid line before the TXV B. energized and open whenever the unit ... so the unit must be modified before using aboard ship D. the water inlet for the ice maker

Last Answer : Answer: D

Description : To stop the electric motor shown in the illustration, the stop button is depressed, causing ____________. EL-0012 A. coil 'MS' to become de-energized B. contacts 'CR1' and 'MR4' to open C. contacts 'MR1', 'MR2', and 'MR3' to open D. contacts 'MS1', 'MS2', and 'MS3' to open

Last Answer : Answer: C

Description : The purpose of 'R6' in the winch circuit shown in the illustration is to _______________. EL-0102 A. maintain dry conditions within the winch brake box B. keep the series field current at ... to assist the winch in stopping D. limit the armature current during lowering operation with heavy loads

Last Answer : Answer: C

Description : When testing for blown fuses in a three-phase supply circuit to a motor, you should first ___________________. A. apply the megger across the tops of the line fuses B. apply an ammeter diagonally across ... of the line fuses D. ensure the circuit is de-energized, and then use a continuity tester

Last Answer : Answer: D

Description : Before touching a small capacitor connected to a de-energized circuit, or even one that is completely disconnected, you should ____________. A. gently tap the body with a screwdriver B. tag it ... insulated fuse puller D. short circuit the terminals to make sure that the capacitor is discharged

Last Answer : Answer: D

Description : The 'safe switch' of the winch controller shown in the illustration is operated _______________. EL-0102 A. through the master switch handle B. when heater circuit current is high C. by contactor coil 'FR' D. manually by the winch operator

Last Answer : Answer: D

Description : If a magnetic controller contact fails to pick up when the operating coil is energized, one possible cause may be _______________. A. low spring pressure B. low voltage to the coil C. the residual magnetism of the contact faces D. dirty contact faces

Last Answer : Answer: B

Description : Before working on an electric cargo winch master switch or controller, you should _____________. A. spray the gasket surface with a solvent B. drain condensate from the box C. open the circuit breaker in the power supply and tag D. heat the switch box to remove any moisture

Last Answer : Answer: C

Description : You are using a mechanical voltage tester to check the fuses in a three-phase circuit supplying an electric motor. For which of the following reasons must the motor be stopped during the test? A. ... circuit would be indicated by the voltage tester with the circuit energized. D. All of the above.

Last Answer : Answer: B

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : The heaters for the winch circuit shown in the illustration are powered from _____________. EL-0102 A. a separate source B. the winch main bus C. the master switch power circuit D. the contactor control circuit

Last Answer : Answer: A

Description : What common shipboard system does figure 'A' represent? EL-0092 A. Navigational running lights B. Rudder angle indicator C. Sound powered telephone D. Winch speed control

Last Answer : Answer: B

Description : Which of the damages listed can occur to the components of a winch master control switch, if the cover gasket becomes deteriorated? A. Overheating of the winch motor. B. Contamination of lube oil. C. Sparking at the winch motor brushes. D. Rapid corrosion of switch components.

Last Answer : Answer: D

Description : The 'reset' contacts of the master switch shown in the illustration are ______________. EL-0102 A. closed only when the master switch is 'off' B. closed only when the master switch selects a 'run' condition C. opened separately by the winch operator D. opened when line voltage drops 10%

Last Answer : Answer: A

Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck

Last Answer : Answer: A

Description : A long solenoid carrying a current I is placed with its axis vertical as shown in the figure. A particle of mass m and charge q is released from the t

Last Answer : A long solenoid carrying a current I is placed with its axis vertical as shown in the figure. A particle of ... than g C. equal to g D. None of these

Description : How will a molded-case circuit breaker react after it has tripped, as a result of an overloaded circuit? A. The breaker will trip again if immediately reset. B. The breaker handle will lock in ... down. D. The breaker handle cannot be moved to the OFF position until the thermal element cools down.

Last Answer : Answer: A

Description : When the operating handle of a molded-case circuit breaker is in the mid-position, this indicates that the circuit breaker is _____________. A. on B. off C. reset D. tripped

Last Answer : Answer: D

Description : In the arrangement shown below, two trucks A and B are held in position with spring compressed. When they are released and the spring has fallen away, A is found to be moving to the left at 2 m/s. The energy stored in the compressed spring was (a) 12 J (b) 24 J (c) 18 J (d) 36 J

Last Answer : Ans:(b) Direction: In the following question, a statement of Assertion (A) is given followed by corresponding Reason (R), just below it. Read the statements carefully and mark the correct answer: (a) If both A and ... true but R is not the correct explanation of A. (c) If A is true but R is false

Description : A spring with a force constant of 20 newtons per meter is known to obey Hooke's Law. The spring is attached to a mass of 5 kilograms and placed on a horizontal, frictionless surface. The ... and released. What is the kinetic energy of the mass as it passes through its equilibrium position? 

Last Answer : ANSWER: 90 JOULES

Description : In a faceplate-type motor starter, the starting arm is held in the 'OFF' position by a/an _____________. A. cotter pin B. magnet C. electrical circuit D. strong spring

Last Answer : Answer: D

Description : In the illustration, when the energy saver switch is in the 'lo' position, the _________. EL-0043 A. mullion and frz flange heaters will not energize B. mullion heater and refrig light will ... energize D. range of the freezer temperature control is increased causing the cut-in temp to become warmer

Last Answer : Answer: A

Description : In the illustration, when the energy saver switch is in the 'lo' position _________. EL-0042 A. the mullion and frz flange heaters will not energize B. the mullion heater and refrig light will ... D. the range of the freezer temperature control is increased causing the cut-in temp to become warmer

Last Answer : Answer: A

Description : Reciprocating compressor are provided with A. Simple disc/plate valve B. Poppet valve C. Spring-loaded disc valve D. Solenoid valve.

Last Answer : ANSWER : A

Description : The magnetic field is _________ inside a solenoid a) Zero b) uniform c) non-uniform d) infinite

Last Answer : b) uniform

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : The direction of rotation of the winch shown in the illustration is changed by reversing the _____________. EL-0102 A. direction of current through the shunt field B. polarity of voltage at 'S1' and 'S2' C. direction of current through the armature D. polarity of voltage at 'L1' and 'L2'

Last Answer : Answer: C

Description : Which of the listed conditions occur when '4th point lower' is selected on the winch shown in the illustration? EL-0102 A. Master switch contacts '3', '4', '6', '8', '9', & '10' close. B. Contactors '2, 3, & 4M' and ' ... , '7', '8', and '9' close. D. Contactors '1 & 3M' and '1, 2, & 3A' pick up.

Last Answer : Answer: B

Description : Which of the listed conditions occur when selection is made for 'third point hoist' on the winch shown in the illustration? EL-0102 A. Master switch contacts '5', '6', '7', '8', and '9' close. B. Contactors '2M', ' ... ' and '2A' drop out. D. Master switch contacts '3','4', '6', '8', and '9' close.

Last Answer : Answer: D

Description : The progressive operation of the contactors marked 'A' provide the winch shown in the illustration with __________. EL-0102 A. accumulation B. dynamic braking C. acceleration D. regenerative braking

Last Answer : Answer: C

Description : The 'reset' contacts of the master switch shown in the illustration provides the winch controller with ___________. EL-0102 A. low voltage release B. overload protection C. low voltage protection D. high power factor correction

Last Answer : Answer: C