When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'

1 Answer

Answer :

Answer: C

Related questions

Description : Which of the listed conditions occur when selection is made for 'third point hoist' on the winch shown in the illustration? EL-0102 A. Master switch contacts '5', '6', '7', '8', and '9' close. B. Contactors '2M', ' ... ' and '2A' drop out. D. Master switch contacts '3','4', '6', '8', and '9' close.

Last Answer : Answer: D

Description : Which of the listed conditions occur when '4th point lower' is selected on the winch shown in the illustration? EL-0102 A. Master switch contacts '3', '4', '6', '8', '9', & '10' close. B. Contactors '2, 3, & 4M' and ' ... , '7', '8', and '9' close. D. Contactors '1 & 3M' and '1, 2, & 3A' pick up.

Last Answer : Answer: B

Description : When the operating handle is in the 'off' position, which master switch contacts for the winch shown in the illustration are closed? EL-0102 A. 'MS-DB & OL' B. 'MS-3, 5, 6, 7, & 8' C. 'MS-LVa & OL' D. 'MS-3, 7 & Reset'

Last Answer : Answer: D

Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : The 'safe switch' of the winch controller shown in the illustration is operated _______________. EL-0102 A. through the master switch handle B. when heater circuit current is high C. by contactor coil 'FR' D. manually by the winch operator

Last Answer : Answer: D

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : The 'reset' contacts of the master switch shown in the illustration are ______________. EL-0102 A. closed only when the master switch is 'off' B. closed only when the master switch selects a 'run' condition C. opened separately by the winch operator D. opened when line voltage drops 10%

Last Answer : Answer: A

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : Which component is responsible for energizing solenoid 'B1-B2' and releasing the brake for the winch motor shown in the illustration? EL-0102 A. Contactor '3M' B. A spring not shown in the schematic diagram C. Resistor 'B2-R1' D. Relay 'FR-B.O.'

Last Answer : Answer: A

Description : The purpose of the 'heater resistors' for the winch circuit shown in the illustration is to _______________. EL-0102 A. limit the current in the heater circuit B. dispel moisture in the ' ... panel C. keep the winch brake housing below the dew point D. maintain winch motor operating temperature

Last Answer : Answer: B

Description : In order to prevent the winch shown in the illustration from turning while troubleshooting the controller circuit, _________________. EL-0102 A. set the dynamic brake by clamping contact 'DB' closed B. set the ... at 'B1' and 'B2' D. open the test link preventing current flow to the armature

Last Answer : Answer: D

Description : The heaters for the winch circuit shown in the illustration are powered from _____________. EL-0102 A. a separate source B. the winch main bus C. the master switch power circuit D. the contactor control circuit

Last Answer : Answer: A

Description : The 'reset' contacts of the master switch shown in the illustration provides the winch controller with ___________. EL-0102 A. low voltage release B. overload protection C. low voltage protection D. high power factor correction

Last Answer : Answer: C

Description : As shown in the illustration, once the "LV" relay is energized for operation, what contacts must remain closed to maintain the "LV" relay energized when the control lever is moved away from the "off" or "stop" ... . B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : The direction of rotation of the winch shown in the illustration is changed by reversing the _____________. EL-0102 A. direction of current through the shunt field B. polarity of voltage at 'S1' and 'S2' C. direction of current through the armature D. polarity of voltage at 'L1' and 'L2'

Last Answer : Answer: C

Description : The progressive operation of the contactors marked 'A' provide the winch shown in the illustration with __________. EL-0102 A. accumulation B. dynamic braking C. acceleration D. regenerative braking

Last Answer : Answer: C

Description : The purpose of resistor bank 'R1-R5' in the winch circuit shown in the illustration is to ______________. EL-0102 A. limit armature current in lower and 'series field' current in hoist to ... required speeds D. regulate the strength of the brake solenoid 'B1-B2' in both directions of operation

Last Answer : Answer: C

Description : The purpose of 'R6' in the winch circuit shown in the illustration is to _______________. EL-0102 A. maintain dry conditions within the winch brake box B. keep the series field current at ... to assist the winch in stopping D. limit the armature current during lowering operation with heavy loads

Last Answer : Answer: C

Description : Which of the devices shown in the illustration automatically prevents the simultaneous operation of the windlass from both master switches? EL-0073 A. Selector switch B. Contact 'CR1a' C. Contact 'CR2a' D. Contact 'CR1D'

Last Answer : Answer: D

Description : As shown in the illustration, all 'MS' contacts are opened and closed by means of ________. EL-0073 A. operating coils B. magnets C. manual operation of the master switches D. solenoid switches

Last Answer : Answer: C

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'OFF' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: A

Description : If the circuit shown in the illustration were energized and operating properly, which of the devices listed would be open? EL-0007 A. The stop push-button B. The start push-button C. Contact 'Ma' D. Contact 'OL1'

Last Answer : Answer: B

Description : Moisture damage, as a result of condensation occurring inside of the cargo winch master switches, can be reduced by __________________. A. installing a light bulb in the pedestal stand B. coating the ... epoxy sealer C. venting the switch box regularly D. using strip heaters inside the switch box

Last Answer : Answer: D

Description : As shown in the illustration, 'H1' and 'H2' are ___________. EL-0058 A. fixed capacitors B. variable capacitors C. contacts, closed when the circuit is energized D. contacts, open when the circuit is energized

Last Answer : Answer: D

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'TEST' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: B

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'ON' position, contacts '3,4' and '7,8' are respectively ______________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: D

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : Which of the damages listed can occur to the components of a winch master control switch, if the cover gasket becomes deteriorated? A. Overheating of the winch motor. B. Contamination of lube oil. C. Sparking at the winch motor brushes. D. Rapid corrosion of switch components.

Last Answer : Answer: D

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : When the control handle is in the 'off' position, the solenoid actuated brake of the electric winch is _________. A. de-energized and the brake is released B. energized and the brake is released C. energized and the brake is set by a spring D. de-energized and the brake is set by a spring

Last Answer : Answer: D

Description : As shown in the illustration, which of the listed actions of the synchroscope pointer is occurring? EL-0002 A. Revolving slowly in the slow direction. B. Revolving rapidly in the slow direction. C. ... stationary at the 12 o'clock position since the leading edges of the A phases are in phase.

Last Answer : Answer: C

Description : As shown in the illustration, the symbol is used in electrical drawings to designate a ____________. EL-0026 A. limit switch with one set of normally open contacts B. maintaining type ... type push button with a mechanical interlock D. normally closed contact held open mechanically by an interlock

Last Answer : Answer: C

Description : 'A-1', as shown in the illustration, is/are ____________. EL-0017 A. normally-closed overload relay contacts B. a double pole knife switch C. normally-open overload relay contacts D. a single pole knife switch

Last Answer : Answer: A

Description : An open-circuit fault between the pressure switch and the 'annunciator module' shown in the illustration would cause the alarm circuit to react in the same manner as if ___________. EL-0094 A. 3.5 ... below switch setting C. 50 PSI were applied to the 'setpoint module' D. the pressure switch closed

Last Answer : Answer: B

Description : The illustrated motor fails to start and gives a loud hum when the start button is depressed, your first action should be to __________. EL-0007 A. disassemble the motor to fix the centrifical ... D. hold the 'M' contactor closed by hand while wearing electrical safety gloves to get motor started

Last Answer : Answer: B

Description : To stop the electric motor shown in the illustration, the stop button is depressed, causing ____________. EL-0012 A. coil 'MS' to become de-energized B. contacts 'CR1' and 'MR4' to open C. contacts 'MR1', 'MR2', and 'MR3' to open D. contacts 'MS1', 'MS2', and 'MS3' to open

Last Answer : Answer: C

Description : When the motor shown in the illustration is running and the stop button is pushed, which of the following statements will hold true? EL-0010 A. Coil 'M' will now be energized. B. Coil 'CR' will now be energized. C. Contact 'M' will close as contact 'CR' opens. D. Contacts 'M' and 'CR' will open.

Last Answer : Answer: D

Description : What controls rudder movement when the Operation Selector Switch shown in the illustration is in the 'NFU' position? EL-0097 A. Steering wheel B. Non-followup controller C. Gyro-compass D. Course selector pointer

Last Answer : Answer: B

Description : What controls the rudder when the 'operation selector switch' of the steering stand shown in the illustration is in the 'HAND' position? EL-OO98 A. Non-followup controller B. Gyro-compass C. Course selector pointer D. Steering wheel

Last Answer : Answer: D

Description : As shown in the illustration, what happens when 'A' is closed, 'B' is in position '2' and component 'E2' burns out? EL-0058 A. 'H' energizes and 'D' makes contact. B. 'F' goes out allowing 'G' to disconnect. C. 'G' sounds an alarm and 'F' illuminates. D. 'C' opens causing 'A' to also open.

Last Answer : Answer: C

Description : A faulty 'function generator' shown in the illustration may prevent _____________. EL-0095 A. proper pitch control from both the 'bridge' and 'engine room thrust levers' B. the 'split potentiometer ... control pitch C. the pitch meter from indicating accurately D. relays #2 and/or #3 from energizing

Last Answer : Answer: A

Description : Power necessary to operate the horn relay shown in the illustration ____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through the relay's contacts D. also lights lamps 'R' and 'T'

Last Answer : Answer: A

Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'

Last Answer : Answer: C