What is the difference between slip and weld neck flange?

1 Answer

Answer :

There are some difference between ANSI Stainless Steel Welding Neck Flange and ANSI Stainless Steel Slip On Flange:1. Welding forms are differernt. Welding Neck Flange can be radiographed but slip on flanges can not. The form of welding betweent welding neck flange and pipe is circular weld , but the between slip on flange and pipe is fillet weld.2. Materials are different. The Welding neck flange’s material is usually made of forged steel parts by machining. While the Slip On Flange’s material that conforms to the common requirements of the steel plate thickness and made by machining.3. Nominal pressures are different. The nominal pressure of the Welding neck flange is 1-25MPa, and the grade is higher. Nominal pressure of slip on flange is 0.6-4MPa grade, compared with the butt weldin

Related questions

Description : Ratings for welding neck flanges under ASME B16.5 are based upon which of the following? a) The flange thickness and 40,000 psi yield strength. b) The hub thickness at the welding end and ... psi yield strength. c) The weld metal yield strength. d) The piping wall thickness and yield strength.

Last Answer : b) The hub thickness at the welding end and 40,000 psi yield strength

Description : Tandem rig test with 450 probe for AT weld detects. (i) Horizontal longitudinal defect in weld. (ii) Vertical oriented defect in AT weld.* (iii) Transverse defect in AT weld. (iv) Defect in flange of AT welds.

Last Answer : (ii) Vertical oriented defect in AT weld.*

Description : What is the difference between rail flange of 60 kg & 52 rail section a. 20 mm b. 18 mm c. 14 mm* d. 16 mm

Last Answer : c. 14 mm

Description : When having windows installed, is it foolish to do have them do it without the flange? They are offereing lifetime warranty on the installation.

Last Answer : A properly installed and flashed flange may help protect against water damage in the future. If It were my home, I would make my decision based on my time horizon for living there. If I didn't see myself ... some reason, I would include the flange. If you will be gone in five years, don't bother.

Description : Why flange of train wheel is inside the track?

Last Answer : Why not have them on both? Surely then they would be safer? I don’t know to be honest and would have to ask people/research and I am so tired, and it is late. Maybe someone else can shed more light on the situation :)

Description : If the distance to electric train is given by Fr = a + bv + cv2 In this equation constant c is likely to cover a.air resistance b.track resistance c.frictional resistance d.flange resistance e.107 dynes

Last Answer : a. air resistance

Description : How can the flange be cut away from the mould?

Last Answer : Need answer

Description : Toilet Flange Repair?

Last Answer : When a toilet rocks like a rocking chair, leaks water around the floor connection or displays other signs of insecure foundation, the toilet flange needs replaced or reset. A toilet flange is the metal ... screwing the flange to the floor. Place wax rings and remount the toilet with bolts and nuts.

Description : How much would it cost to buy the pieces to do a toilet flange repair kit?

Last Answer : The cost to replace just the toilet flange is around $5. The tricky part is knowing how to install it. If you use an outside source the cost will go up accordingly.

Description : How can I replace a toilet flange?

Last Answer : 1. Loosen the 2 nuts that are located on each side of the toilet. Place them in a safe location, because you will need them to remount the toilet.2. Lift the toilet. Set it in a place where the ... line. This can be done, from inside the pipe, using a Dremel tool with a reinforced disk for cutting.

Description : How to Install a New Toilet Flange?

Last Answer : Installing a new toilet flange is a fairly simple process that should take no more than 15 to 20 minutes. A properly installed toilet flange will ensure years of dependable use. If the old ... over tightened, the porcelain toilet will crack.Your new toilet flange is installed and ready to use.

Description : In the illustration, when the energy saver switch is in the 'lo' position, the _________. EL-0043 A. mullion and frz flange heaters will not energize B. mullion heater and refrig light will ... energize D. range of the freezer temperature control is increased causing the cut-in temp to become warmer

Last Answer : Answer: A

Description : In the illustration, when the energy saver switch is in the 'lo' position _________. EL-0042 A. the mullion and frz flange heaters will not energize B. the mullion heater and refrig light will ... D. the range of the freezer temperature control is increased causing the cut-in temp to become warmer

Last Answer : Answer: A

Description : Find the shear stress in a flange at the junction of hub in rigid flanged coupling if torsional moment is 2980N-m and diameter of hub being 125mm. Also the thickness of flange is 25mm. a) 6.77N/mm2 b) 10.24N/mm2 c) 4.84N/mm2 d) 4.22N/mm2

Last Answer : c) 4.84N/mm2

Description : If shaft diameter is 60mm, how many bolts are recommended for rigid flange coupling? a) 2 b) 3 c) 4 d) 5

Last Answer : c) 4

Description : Power is transmitted by only in rigid flange coupling. a) True b) False

Last Answer : b) False

Description : A flange coupling is used to connect two shafts A. Which are perfectly aligned B. Which are not in exact alignment C. Have lateral misalignment D. Whose axes intersect at a small angle

Last Answer : A. Which are perfectly aligned

Description : Flange coupling is rigid types coupling. A. True B. False

Last Answer : A. True

Description : Flange coupling is ............ types of coupling. A. Flexible B. Rigid

Last Answer : B. Rigid

Description : Flange coupling is rigid types coupling. A. True B. False

Last Answer : A. True

Description : While designing a flange coupling, care is taken so that (A) Shaft is the weakest component (B) Bolts are the weakest component (C) Key is the weakest component (D) The flange is the weakest component

Last Answer : (C) Key is the weakest component

Description : A bushed-pin type flange coupling is used (A) For intersecting shafts (B) When the shafts are not in exact alignment (C) For small shafts rotating at slow speeds (D) For parallel shafts

Last Answer : (B) When the shafts are not in exact alignment

Description : If shaft diameter is 60mm, how many bolts are recommended for rigid flange coupling? a) 2 b) 3 c) 4 d) 5

Last Answer : c) 4

Description : Power is transmitted by only in rigid flange coupling. a) True b) False

Last Answer : b) False

Description : In designing a flange coupling, the pitch circle diameter of bolts is taken as (where d = Diameter of the shaft) (A) 2 d (B) 3 d (C) 4 d (D) 5 d

Last Answer : (B) 3 d

Description : Most commonly used joint in the underground pipe lines is the (A) Sleeve joint (B) Coupling (C) Flange (D) Expansion joint

Last Answer : (A) Sleeve joint

Description : A cast iron T section beam is subjected to pure bending. For maximum compressive stress to be  three times the maximum tensile stress, centre of gravity of the section from flange side is  (A) h/4  (B) h/3  (C) h/2  (D) 2/3 h

Last Answer : (A) h/4 

Description : The width of the flange of a T-beam, which may be considered to act effectively with the rib depends upon (A) Breadth of the rib (B) Overall thickness of the rib (C) Centre to centre distance between T-beams (D) All the above

Last Answer : Answer: Option D

Description : The width of the flange of a T-beam should be less than (A) One-third of the effective span of the T-beam (B) Distance between the centres of T-beam (C) Breadth of the rib plus twelve times the thickness of the slab (D) Least of the above

Last Answer : Answer: Option D

Description : An intermediate T-beam reinforced with two layers of tensile steel with clear cover 13 cm encasted with the floor of a hall 12 metres by 7 metres, is spaced at 3 metres from adjoining beams and if the width of the beam is ... breadth of the flange is (A) 300 cm (B) 233 cm (C) 176 cm (D) 236 cm

Last Answer : Answer: Option C

Description : A T-beam behaves as a rectangular beam of a width equal to its flange if its neutral axis (A) Remains within the flange (B) Remains below the slab (C) Coincides the geometrical centre of the beam (D) None of these

Last Answer : Answer: Option A

Description : A part of the slab may be considered as the flange of the T-beam if (A) Flange has adequate reinforcement transverse to beam (B) It is built integrally with the beam (C) It is effectively bonded together with the beam (D) All the above

Last Answer : Answer: Option D

Description : If depth of slab is 10 cm, width of web 30 cm, depth of web 50 cm, centre to centre distance of beams 3 m, effective span of beams 6 m, the effective flange width of the beam, is (A) 200 cm (B) 300 cm (C) 150 cm (D) 100 cm

Last Answer : Answer: Option C

Description : The neutral axis of a T-beam exists (A) Within the flange (B) At the bottom edge of the slab (C) Below the slab (D) All the above

Last Answer : Answer: Option D

Description : The width of the flange of a L-beam, should be less than (A) One-sixth of the effective span (B) Breadth of the rib + four times thickness of the slab (C) Breadth of the rib + half clear distance between ribs (D) Least of the above

Last Answer : Answer: Option D

Description : Where blind flange is used?

Last Answer : Answer: It is used with view to future expansion of the piping system, or for cleaning, inspection etc.

Description : Where jacked screwed flange is used?

Last Answer : Answer: For spectacle discs, one flange is jacked screw flange. This flange has two jacked screws 180 degree apart which are used to create sufficient space between flange for easy removal and placement of line blind or spectacle blind.

Description : The ratio of the thickness of web to that of flange of steel rolled structural beams and channels is (A) Less than 1 (B) Equal to 1 (C) Greater than 1 (D) Less than 1 in beams but greater than 1 in channels

Last Answer : Answer: Option A

Description : In grillage foundations a minimum 15 cm cover is provided on (A) Upper flange of top tier (B) Lower beam of lower tier (C) Ends of external beams (D) None to these

Last Answer : Answer: Option B

Description : What Is The Empirical Formula Used To Give The Number Of Bolts In Flange Coupling?

Last Answer : n = 0.2d + 3

Description : What Is A Flange Coupling?

Last Answer : It is very common type of coupling used to connect the shafts by means of two flanges. Two cast iron flanges are fitted with key to the ends of the two shafts to be connected and fastened together by means of bolts and nuts.

Description : In grillage foundations, distance between flanges of grillage beams, is kept (A) 40 cm (B) Equal to flange width (C) Twice the flange width (D) Maximum of (a), (b) and (c)

Last Answer : Answer: Option C

Description : What Is Flange? Types Of Flanges?

Last Answer : Flanges used to connect both lines (Fluid, Gas, Oil, Water….)  Thread Type Flange  Modified Flange  Weld Neck Flange  Slip On Flange  Goose Neck Flange  Socket Weld Flange  Stepped Flange  Spade Flange  Spectacle Flange  Blind Flange

Description : Consider the following statements in respect of design of web and flange as splices: 1. Flange splice shall be designed for actual BM at the section. 2. Flange splice shall be designed to resist the actual shear at the section. 3. Web ... are correct? (a) 1 and 3 (b) 2 and 3 (c) 3 and 4 (d)1 and 4

Last Answer : (a) 1 and 3

Description : The neutral axis in a T-beam section falls (a) Within the flange (b) Outside the flange (c) Either (a) or (b) (d) All the above

Last Answer : (c) Either (a) or (b)

Description : The effective depth of a T-beam is the distance between the (a) Centre of the flange and the top of the tensile reinforcement (b) Top of the flange and the centre of the tensile ... centre of the tensile reinforcement (d) Centre of the flange and the bottom centre of the tensile reinforcement

Last Answer : (b) Top of the flange and the centre of the tensile reinforcement

Description : In a T-beam, the vertical distance between the bottom of the flange and the centre of the tensile reinforcement is (a) Breadth of flange (b) Thickness of flange (c) Breadth of slab (d) Depth of rib

Last Answer : (d) Depth of rib

Description : Slab forms the compression flange of the T-beam (a) Yes (b) No (c) Not known (d) None of these

Last Answer : (a) Yes

Description : The thickness of flange in a T-beam is taken equal to the total thickness of the slab, including cover. (a) True (b) False (c) Not known (d) None of these

Last Answer : (a) True

Description : The breadth of the flange of a T-beam is (a) 1/3rd of the effective span of the T-beam (b) Twelve times the depth of slab plus breadth of rib. (c) Centre to centre distance between the adjacent beam. (d) Least of (a) , (b) or (c)

Last Answer : (d) Least of (a) , (b) or (c)