Description : What is the maximum current allowed to be drawn from the secondary of a 2 KVA step-down transformer with a turns ratio of four to one if connected across a 440 volt line? A. 1.1 amps B. 4.5 amps C. 18.1 amps D. 22.7 amps
Last Answer : Answer: C
Description : What is the maximum allowable primary current of a 2 KVA step-down transformer with a four to one turns ratio if connected across a 440 volt line? A. 1.1 amps B. 4.5 amps C. 18.1 amps D. 27.7 amps
Last Answer : Answer: B
Description : Relative to the secondary winding of a step-up transformer, the primary winding will have _____________. A. more turns B. fewer turns C. half as many turns D. twice as many turns
Description : When a transformer is used to step down voltage, the low voltage winding is _____________. A. part of the core B. the primary coil C. not insulated D. the secondary coil
Last Answer : Answer: D
Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be (A) 3.6 V. (B) 2.5 V. (C) 3.0 V. (D) 6.0 V.
Last Answer : (C) 3.0 V.
Last Answer : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be 3.0 V.
Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be; (A) 3.6 (B) 2.5 V (C) 3.0 V (D) 6.0 V
Last Answer : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be: 3.0 V
Description : A load with an impedance of 440 ohms is connected across the secondary of the transformer illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given
Description : A load is connected to the secondary of the transformer illustrated and the current through the load is 10 amps. If the step-up ratio is 10 to 1 and the input voltage is 110 VAC, what will be the current flow through the primary? EL-0055 A. 1 amp B. 10 amps C. 100 amps D. 1000 amps
Description : A 1:5 step-up transformer has 120V across the primary and 600 ohms resistance across the secondary. Assuming 100% efficiency, the primary current equals (A) 0.2 Amp. (B) 5 Amps. (C) 10 Amps. (D) 20 Amps.
Last Answer : I1= V1 /R1 = 120/600 = 0.2 (η = 100%, losses are zero ∴V1 = VR = I1R1)
Description : A certain transformer has 400 turns in the primary winding and 2,000 turns in the secondary winding. The turns ratio is? A.0.2 B.0.4 C.5 D.25
Last Answer : A certain transformer has 400 turns in the primary winding and 2,000 turns in the secondary winding. The turns ratio is? A.0.2 B.0.4 C.5 D.25
Description : If a transformer has 50 turns in the primary winding and 10 turns in the secondary winding, what is the reflective resistance if the secondary load resistance is 250 ohms? A.250 ohms B.25 ohms C.6,250 ohms D.62,500 ohms
Last Answer : 6,250 ohms
Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary? (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts
Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary? (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts
Description : In transformer, alternating current is induced inA. primary coil B. secondary coil C. iron core D. resistor
Last Answer : primary coil
Description : The hook-on AC volt-ammeter consists essentially of a split-core and a rectifiertype instrument connected to the secondary winding of a _____________. A. potential transformer B. control transformer C. current transformer D. reactance transformer
Description : If the illustrated device has a step-up ratio of 10 to 1 what voltage be measured at the secondary shortly after the primary of the device is connected to 110 volts DC with a current of 12 amps? EL-0055 A. 0 volts B. 110 volts C. 1000 volts D. 1100 volts
Last Answer : Answer: A
Description : A 1:5 step-up transformer has 120V across the primary and 600 ohms resistance across the secondary. Assuming 100% efficiency, the primary current will be: (A) 0.2 Amp. (B) 5 Amps. (C)10 Amps. (D) 20 Amps
Last Answer : C. 10A
Description : What is the output current of a 480 Volt primary 208 volt secondary - 3 phase transformer?
Last Answer : You need to mention the Load connected to find the current.
Description : 12] Which is not the basic element of the transformer? A. core B. primary winding C. secondary winding D. mutual flux
Last Answer : D. Mutual flux
Description : If a 120v transformer has 200 turns the secondary winding has 20 turns what is the secondary winding voltage?
Last Answer : 12v
Description : What is the secondary winding voltage if a 120v transformer has 200 turns the secondary winding has 20 turns?
Last Answer : 12 volts
Description : A load with an impedance of 440 ohms is connected across the secondary of the device illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given
Description : A load is connected to the secondary of the device illustrated and the current through the load is 10 amps. If the step-up ratio is 10 to 1 and the input voltage is 110 VAC, what will be the current flow through the primary? EL-0055 A. 1 amp B. 10 amps C. 100 amps D. 1000 amps
Description : A transformer steps down 220V to 40 volts. If the secondary turns are 40 then primary turns will be: a. 20 b. 40 c. 120 d. 220
Last Answer : d. 220V
Description : When the turns ratio of a transformer is 20 and the primary ac voltage is 12 V, the secondary voltage is? A.12 V B.120 V C.240 V D.2,400 V
Last Answer : When the turns ratio of a transformer is 20 and the primary ac voltage is 12 V, the secondary voltage is? A.12 V B.120 V C.240 V D.2,400 V
Description : When used for taking resistance measurements, a volt-ohm-milliammeter is normally powered by _____________. A. a hand cranked generator B. internal storage batteries C. the current in the circuit being tested D. a step down transformer
Description : A 1100 kVA, 11 kV/1.1 kV conventional two-winding transformer is connected as a 12.1 kV/11 kV step-down auto-transformer. The rating of the auto-transformer is (A) 1000 kVA (B) 1100 kVA (C) 11000 kVA (D) 12100 kVA
Last Answer : A 1100 kVA, 11 kV/1.1 kV conventional two-winding transformer is connected as a 12.1 kV/11 kV step-down auto-transformer. The rating of the auto-transformer is 12100 kVA
Description : The turns ratio of a transformer having 200 primary turns and 1,200 secondary turns is? A.6 B.24 C.1.66 D.66
Last Answer : The turns ratio of a transformer having 200 primary turns and 1,200 secondary turns is? A.6 B.24 C.1.66 D.66
Description : 21.The ordinary two winding transformer's primary and secondary windings always have A. different no of turns B. same size of copper wire C. a common magnetic circuit D. separate magnetic circuits
Last Answer : C. A common magnetic circuit
Description : For a 100% efficient transformer, the primary winding has 1000 turns and the secondary 100 turns. If the power input to the above transformer is 1000 watts, the power output is_________.
Last Answer : For a 100% efficient transformer, the primary winding has 1000 turns and the secondary 100 turns. If the power input to the above transformer is 1000 watts, the power output is 1000 watts.
Description : Which of the following statements identifies the difference between the primary windings and the secondary windings of a 2:1 stepdown transformer? A. The secondary windings have twice as much resistance ... primary windings. D. The secondary windings have half as many turns as the primary windings.
Description : 29.In transformer terminology, the ratio 20:1 indicates that A. there are 20 turns on primary one turn on secondary B. secondary voltage is 1/20th of the primary C. primary current is 20 times greater than the secondary current D. for every 0 turns on primary, there is one turn on secondary
Last Answer : A. there are 20 turns on primary one turn on secondary
Description : Figure 'D' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts
Description : Figure 'C' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts
Description : Figure 'B' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts
Description : Figure 'A' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts
Description : In the illustration, if the device in figure 'A' has a step-up ratio of 10 to 1, what voltage should be measured at the secondary shortly after the primary of the device is connected to 110 volts DC? EL-0059 A. 0 volts B. 110 volts C. 11 volts D. 1100 volts
Description : In a tap changing transformer, the tappings are provided on (a) primary winding (b) secondary winding (c) high voltage winding (d) any of the above
Last Answer : (b) secondary winding
Description : 28.In a two winding transformer, the emf /turn in secondary winding is always......the induced emf power turn in primary A. equal to k times B. equal to 1/k times C. equal D. greater than
Last Answer : C. equal
Description : 6 In a two winding transformer, the primary and secondary induced emf E1 & E2 are always A. equal in magnitude B. anti phase with each other C. in phase with each other D. determined by load on transformer secondary
Last Answer : C. In phase with each other
Description : If we give 2334 A, 540V on Primary side of 1.125 MVA step up transformer, then what will be the Secondary Current, If Secondary Voltage=11 KV?
Last Answer : A. As we know the Voltage & current relation for transformer-V1/V2 = I2/I1 We Know, VI= 540 V; V2=11KV or 11000 V; I1= 2334 Amps. By putting these value on Relation540/11000= I2/2334 So,I2 = 114.5 Amps
Last Answer : As we know the Voltage & current relation for transformer-V1/V2 = I2/I1 We Know, VI= 540 V; V2=11KV or 11000 V; I1= 2334 Amps. By putting these value on Relation540/11000= I2/2334 So,I2 = 114.5 Amps
Description : 52 A transformer has 1000 primary turns, connected to 250V ac supply. To get 400V secondary voltage the no of secondary turns should be A. 1600 B. 250 C. 400 D. 1250
Last Answer : A. 1600
Description : If the secondary turns of a transformer are doubled and at the same time primary voltage is reduced to half then the secondary voltage will
Last Answer : If the secondary turns of a transformer are doubled and at the same time primary voltage is reduced to half then the secondary voltage will not change
Description : A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz supply with secondary winding open circuited. Then (A) Both eddy current and hysteresis losses decreases. (B) Both ... same but hysteresis loss increases. (D) Eddy current loss increases but hysteresis loss remains the same.
Last Answer : (A) Both eddy current and hysteresis losses decreases.
Description : An electric clothes dryer is connected to a 100-volt source. How much current does it use if it requires 2,000 watts of electric power?
Last Answer : 20 Amphere
Description : Used normally, a 150-watt, 120 volt light bulb requires how many amps of current?
Last Answer : ANSWER: 1.25 AMPS
Last Answer : Turns ratio= N1/ N2 IN Scott connection Main transformer turns ratio = N1 /N2 Teaser transformer turns ratio= 0.866N1/N2 Where N1= number of turns in primary winding N2= number of turns in secondary winding
Last Answer : High voltage winding in a transformer has more number of turns.
Last Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.