1 Answer

Answer :

Cable Error To be A Normal Events Which Different Because Become Most Cable Paper Insulation Moist, Damp Become Perforated Is Or Of Cesar Cover Damaged Yes. Cable Lead Cover Damaged To be Because Underground Cable Fault Occurred Is.

Related questions

Description : 2005 Muzaffarabad earthquake was occurred on _______ active fault. (A) Kangra Active fault (B) San Andreas fault (C) Main Boundary thrust (D) Tanda Active fault 

Last Answer : (D) Tanda Active fault 

Last Answer : Cable Fault Detected To do Method ,,,, 1 / Blavier Test 2 / loop Test 3 / Induction Test 4 / voltage Drop Test 5 / Capacity Test .

Description : This is a method of using a Wheatstone brdige to determine the distance from the test point to a fault in a telephone or telegraph line or cable.

Last Answer : varmeter/reactive VA meter

Description : Cable Fault Testing Practical

Last Answer : Practical Significance Cable faults can be occur with insulation damage due to ageing, excess heat, wrong handling, improper termination of cable, and moisture in the soil. To restore the supply fault finding ... and record the reading. 6. Repeat all tests from end B and record all readings.

Last Answer : Open circuit fault in a cable can be located by: Capacity test

Description : In India, maximum ground water depletion has occurred in

Last Answer : In India, maximum ground water depletion has occurred in A. Mumbai B. Delhi C. Punjab D. Tamil nadu.

Description : why would you get a ground fault on a security panel?

Last Answer : Improper grounding.

Description : When a console indicating lamp burns out, attempts to renew it should not be made while maneuvering because _______________. A. the new lamp may be of a higher wattage and cause heat damage to the lens ... D. a socket/wiring fault may cause a ground or short circuit to shut down a vital function

Last Answer : Answer: D

Description : State the significance of single line to ground fault.

Last Answer : In single line to ground fault all the sequence networks are connected in series. All the sequence currents are equal and the fault current magnitude is three times its sequence currents.

Description : Ungrounded neutral transmission system is not recommended because of system (a) insulation being overstressed due to over voltages (b) insulation overstress may lead to failure and subsequent phase to phase faults (c) being inadequately protected against ground fault (d) all of the above

Last Answer : (d) all of the above

Description : A single-line-to-ground fault on a overhead transmission line creates (A) voltage sag (B) voltage swell (C) over voltage (D) voltage flicker 

Last Answer : Creates  overvoltage.

Description : The zero sequence current of a generator for line to ground fault is j 2.4 p.u. The current through the neutral during the fault is (a) j 0.8 p.u (b) j 2.4 p.u. (c) j 0.24 p.u. (d) j 7.2 p.u. 

Last Answer : j7.2

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Last Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : What governmental problem occurred under the articles of confederations?

Last Answer : the state frequently did not corporate with each other

Description : Of the following statements, which best distinguishes ordinary negligence from gross negligence? a. The more material the undetected error the greater the likelihood of ordinary negligence. ... care denotes ordinary negligence, whereas failure to exercise minimal care indicates gross negligence

Last Answer : Failure to exercise reasonable care denotes ordinary negligence, whereas failure to exercise minimal care indicates gross negligence

Description : Needing help connecting a ground cable...

Last Answer : I am not a licensed electrician. Here are the legal disclaimers: Might cause nausea; Your mileage may vary; Past perfromanceis not an assurance of future performance. Ok got it? Usually the cold water pipe is a ... also buy ground rods at Lowe's and pound them in if you don't have a water line.

Description : If your multimeter gives a reading in ohms when testing each end of each conductor of a three-conductor cable, this indicates ______________. A. continuity of the conductor B. an infinite resistance C. the presence of a partial ground D. that the conductor is not short circuited

Last Answer : Answer: A

Description : With both ends of a three conductor cable disconnected and arranged without the conductors touching each other, an ohmmeter reading of 'zero' ohms between the ends of one conductor would indicate _____________. A. continuity B. a partial ground C. the resistance is infinite D. a short circuit

Last Answer : Answer: A

Description : If you disconnect and arrange both ends of a three conductor cable, without any contact between the individual conductors, an indicated ohmic value between the ends of a single conductor would indicate ... resistance C. the presence of a partial ground D. that the conductor is not short circuited

Last Answer : Answer: A

Description : The final step in testing a circuit for a ground involves the use of a megohmmeter. A grounded switch or cable will be indicated by a megohmmeter reading of ____________. A. 'zero' B. infinity C. steady in the high range D. unsteady in the low range

Last Answer : Answer: A