When a console indicating lamp burns out, attempts to renew it should not be made while maneuvering because _______________. A. the new lamp may be of a higher wattage and cause heat damage to the lens B. removing a faulty lamp usually causes an alarm to sound on the bridge C. attention should be paid only to engine orders D. a socket/wiring fault may cause a ground or short circuit to shut down a vital function

1 Answer

Answer :

Answer: D

Related questions

Description : A faulty 'function generator' shown in the illustration may prevent _____________. EL-0095 A. proper pitch control from both the 'bridge' and 'engine room thrust levers' B. the 'split potentiometer ... control pitch C. the pitch meter from indicating accurately D. relays #2 and/or #3 from energizing

Last Answer : Answer: A

Description : When troubleshooting a console circuit card suspected of being faulty, the last step would be to _______________. A. check the fuses and voltage levels of all power supplies in the console B. clean dust ... -on types D. substitute a new or repaired spare card and check the operation of the circuit

Last Answer : Answer: D

Description : In the pitch control diagram shown in the illustration, what are the present plant operating conditions? EL-0095 A. One engine is on the line, cruise mode is selected and the engine room is in control. ... . D. Both engines are on line, maneuvering mode is selected and the engine room is in control.

Last Answer : Answer: D

Description : Vessel pitch can be controlled by either the 'bridge or engine room thrust lever' shown in the illustration; but only with one engine on the line whether in 'cruise or maneuver' mode. The cause is most likely a faulty relay _____________. EL-0095 A. #1 B. #2 C. #3 D. #4

Last Answer : Answer: D

Description : One should not connect a number of electrical appliances to the same power socket because 1. this can damage the appliances 2. this can damage the domestic wiring due to overheating 3. the appliances will not get full voltage Which ... valid reasons? (a) 2 and 3 (b) 2 only (c) 1 and 2 (d) 3 only

Last Answer : Ans:(b)

Description : When a fluorescent lamp has reached the end of its useful life, it should be replaced immediately, or the resultant flashing may _____________. A. blow the lamp's circuit breaker B. explode, ... fly in all directions C. short circuit the ballast transformer D. damage the starter and the ballast

Last Answer : Answer: D

Description : When troubleshooting a console circuit card suspected of being faulty, first check operating voltages, clean the card and then _________________. A. make sure wired connections and push-on connectors ... circuit traces with an ohmmeter D. measure the gain of each transistor or integrated circuit

Last Answer : Answer: A

Description : When troubleshooting a console circuit card which is suspected of being faulty, the first step would be to _____. A. pull the card and measure the value of all resistors B. check for the ... for burned components D. check for continuity of circuit board traces and then the gain of each transistor

Last Answer : Answer: C

Description : In the illustration, the signal from the device connected to terminals 18 and 19 is __________. EL-0046 A. prime mover speed feedback B. loss of control alarm when comparing with the input signal ... slip between the prime mover and the alternator D. to shut down the prime mover if overspeeding

Last Answer : Answer: A

Description : In the illustrated ground detection system with a ground on phase A, if the switch is opened __________. EL-0009 A. lamp A will dim or go out depending on the severity of the ground B. all three ... lamp A will be brighter D. lamp A will start flickering if the ground is in an AC induction motor

Last Answer : Answer: B

Description : A voltmeter located on a control panel has been operating correctly for six months, suddenly burns out. After removing it, it is found that neither side of the meter has been grounded. When ... side and the ground C. installed exactly as the old installation D. grounded to the positive side

Last Answer : Answer: C

Description : An open-circuit fault between the pressure switch and the 'annunciator module' shown in the illustration would cause the alarm circuit to react in the same manner as if ___________. EL-0094 A. 3.5 ... below switch setting C. 50 PSI were applied to the 'setpoint module' D. the pressure switch closed

Last Answer : Answer: B

Description : When soldering a printed circuit board component, you should be careful to prevent damage by _________. A. quickly heating the joints, using a high wattage iron B. using the soldering iron tip sparingly C. using only acid cord solder D. applying mechanical pressure to the joints being soldered

Last Answer : Answer: B

Description : A current-carrying conductor makes accidental contact with a wiring conduit. This will be indicated by a _____________. A. low switchboard wattmeter reading B. high switchboard wattmeter reading C. darkened switchboard ground detecting lamp D. darkened switchboard synchronizing lamps

Last Answer : Answer: C

Description : A three-phase electrical system is equipped with ground detecting lamps. If one of the lamp goes dark and the other two burn normally before and after the test switch is operated, this indicates _______________. ... of the three phases D. the voltage to the dark lamp is less than that of the system

Last Answer : Answer: A

Description : The diagrams shown in the illustration represent a/an _______________. EL-0093 A. engine order telegraph circuit B. rudder angle indicator arrangement C. engine speed tachometer with repeaters D. sound powered telephone system

Last Answer : Answer: D

Description : The meter indicating the position of the 'bridge Thrust lever' shown in the illustration is located ___________________. EL-0095 A. in the Engine Control Room B. on the Bridge C. in the Captain's office D. in the Chief Engineer's office

Last Answer : Answer: A

Description : Why is it a poor practice to use a high wattage soldering iron when soldering or desoldering components on a printed circuit board? A. The circuit board will blister and warp. B. The foil wire bonded ... board has a low melting temperature. D. The solder is kept to a dull heat dissipating finish.

Last Answer : Answer: B

Description : Four lamps are connected in parallel in a single circuit. If one of the lamp burns out, the others will _____________. A. all go out B. become dimmer C. burn with their original intensities D. become brighter

Last Answer : Answer: C

Description : Can I use a higher wattage bulb in a lamp that states 40 watts?

Last Answer : You should not use a higher wattage bulb in a lamp that says 40 watts. The higher wattage could cause the lamp to catch fire due to the excess heat and could cause you serious electrical problems.

Description : Accidental grounds in a shipboard electrical system must be repaired as soon as possible as they will ____________. A. result in immediate power outages B. damage circuit breakers C. appear on the ground detection system D. damage insulation and may cause outages

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR), require that an indicating light at the propulsion control station will operate if overloading or overheating occurs in a _______________. A. forced draft blower motor B. steering gear motor C. fuel pump motor D. condensate pump motor

Last Answer : Answer: B

Description : The 'dielectric constant' is a numerical value indicating the effectiveness of a dielectric material in comparison to that of a standard, which is _______________. A. paper or cloth B. glass or mica C. plastic or Teflon D. dry air or a vacuum

Last Answer : Answer: D

Description : Which of the following precautions should be taken when a blown fuse, rated at 10 amperes, is replaced? A. Short out the fuse before removing it from the circuit. B. Use needle-nose pliers to ... D. Fuses of 10 ampere rating and less are virtually harmless when energized and may be handled freely.

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require manual contactors for operating the general emergency alarm on tank vessels to be located in the navigating bridge, engine room and the ____________. A ... C. crew accommodations and sleeping spaces D. engineering officers' quarters furthest from the bridge

Last Answer : Answer: A

Description : The electrical device shown in the illustration is a/an _____________. EL-0077 A. operating coil B. indicating lamp C. motor armature D. potentiometer

Last Answer : Answer: D

Description : In the illustration, 'D' is the symbol for a/an __________. EL-0005 A. thermal overload heater B. portable cable C. fuse D. indicating lamp

Last Answer : Answer: C

Description : An overload in which of the listed motors will result in the illumination of an indicating light at the propulsion control station alarm panel? A. Fuel pump motor B. Steering motor C. Condensate pump motor D. Forced draft blower motor

Last Answer : Answer: B

Description : In the illustrated 450 VAC system, what should be provided between the bus and the device labeled 'F'? EL-0003 A. a potential transformer B. a current transformer C. an emergency disconnect device D. an audible alarm and indicating light

Last Answer : Answer: A

Description : During the start-up of the circuit shown in the illustration, it is noted that the ends of component 'C' remain lighted but the tube does not illuminate. The cause of this problem is ____________. EL- ... ' is closed C. component 'C' is the wrong wattage D. component 'B' contacts are stuck closed

Last Answer : Answer: D

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : While removing the second primary molar of a 9 years-old child, the apical ¼ of the root fractures and stays in the socket, A. You will just leave it and observe it B. You take surgically by a lingual ... try to take out by using a root apex elevator D. You use a fine-end forceps to take it out

Last Answer : A. You will just leave it and observe it

Description : A ground can be defined as an electrical connection between the wiring of a motor and its ____________. A. shunt field B. circuit breaker C. metal framework D. interpole

Last Answer : Answer: C

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : If 450 volts AC were measured across the load as shown in the illustration it would indicate a/an _______________. EL-0083 A. open winding between 'H1' and 'X1' B. properly operating circuit C. open winding between 'X1' and 'X4' D. ground on one side of 'Ep'

Last Answer : Answer: C

Description : Explain with neat labeled circuit diagram the staircase wiring in which a lamp is controlled from two different locations. 

Last Answer : one lamp controlled from two places: Explanation: 1. The switch S1 (two way switch is located at bottom position of the staircase. 2. The switch S2 is located at top ... the position of S2 lamp will become OFF due to current discontinuity * This process remains continuously 

Description : As shown in the illustration, what happens when 'A' is closed, 'B' is in position '2' and component 'E2' burns out? EL-0058 A. 'H' energizes and 'D' makes contact. B. 'F' goes out allowing 'G' to disconnect. C. 'G' sounds an alarm and 'F' illuminates. D. 'C' opens causing 'A' to also open.

Last Answer : Answer: C

Description : In electronic circuits, DC voltages can be positive (+) or negative (-) when measured with respect to the _________. A. printed circuit board 'common' trace B. chassis, console frame or hull 'ground' C. analogue or digital circuitry 'common' bus D. all of the above

Last Answer : Answer: D

Description : If both the 'high level' and 'low level' alarms come on for the same address of a centralized control console, the most likely problem is a/an ____________. A. sensor failure B. failed alarm C. low level D. extremely high level

Last Answer : Answer: A

Description : My surge protector says "protected" and "faulty wiring" at the same time?

Last Answer : answer:Is it like a UPS backup system? Or is it just one of those normal cheap power strips with surge protection? If it's just one of those normal power strips I wouldn't worry, I'd just go out and ... is surge protection. They have always been on, I can't say I've ever seen my red light go off.

Description : A shuttle valve will: a. Allow the accumulator to be emptied after engine shut down b. Reduce pump loading when normal system pressure is reached c. Automatically switched to a more appropriate source of hydraulic supply d. Operate on a rising pressure, higher than the Full Flow relief valve

Last Answer : c. Automatically switched to a more appropriate source of hydraulic supply

Description : A shuttle valve will: a. Allow the accumulator to be emptied after engine shut down b. Reduce pump loading when normal system pressure is reached c. Automatically switched to a more appropriate source of hydraulic supply d. Operate on a rising pressure, higher than the Full Flow relief valve

Last Answer : c. Automatically switched to a more appropriate source of hydraulic supply