1 Answer

Answer :

A non inverting closed loop op amp circuit generally has a gain factor Greater than one.

Related questions

Last Answer : The closed-loop voltage gain of an inverting amplifier equal to The feedback resistance divided by the input resistance.

Last Answer : If ground is applied to the (+) terminal of an inverting op-amp, the (–) terminal will Be virtual ground.

Description : An OP amp has an open loop gain of 1,00,000. If the feedback fraction is 0.02, the approximate closed loop gain is (a) 1 (b) 1,00,000 (c) 50 (d) 0.02

Last Answer : The closed loop gain Ag = G/(1+G*f) Where G is the open loop gain and f is the feedback fraction  So Ag = 49.975

Description : The closed loop gain of an OPAMP is dependent upon, whether the OP AMP is used : -  a) in inverting mode b) in non -inverting mode c) is independent of the fact whether the ... inverting terminal d) is depending upon the fact whether the input is connected to inverting or non -inverting terminal

Last Answer : The closed loop gain of an OPAMP is dependent upon, whether the OP AMP is used : - is depending upon the fact whether the input is connected to inverting or non -inverting terminal

Description : An Op-amp as a voltage follower has a voltage gain of

Last Answer : An Op-amp as a voltage follower has a voltage gain of Unity

Description : As long as op-amp is not saturated, the potential difference between inverting and non-inverting inputs is A. zero B. infinite C. 1 D. 2

Last Answer : zero

Description : Why are the 2 input terminals of an op-amp are called as inverting & non-inverting terminals?

Last Answer : Ans-Because if we give input to one input means that will produce the same phase output where as the other(Inverting) pin produce 180 degree phase shifted output.

Description : What is the type of feedback employed in the inverting op-amp amplifier?

Last Answer : Negative feedback is employed in the inverting op-amp amplifier.

Description : Actual op-amp may have an open loop gain of A. 102 B. 105 C. 103 D. 104

Last Answer : 105

Description : For a feedback amplifier, if the loop gain is much greater than unity, the closed loop gain will be equal to

Last Answer : For a feedback amplifier, if the loop gain is much greater than unity, the closed loop gain will be equal to inverse of feedback factor

Description : The unity gain bandwidth of an inverting amplifier is 10 MHz What would be the bandwidth if the gain is increased to 10 V/V? A) 100 MHz B) 1 MHz C) 10 MHz D) 1 kHz 

Last Answer : The unity gain bandwidth of an inverting amplifier is 10 MHz What would be the bandwidth if the gain is increased to 10 V/V? A) 100 MHz B) 1 MHz C) 10 MHz D) 1 kHz 

Description : The input impedance of an op-amp is • High • Low • Medium • None of the above

Last Answer : The input impedance of an op-amp is High

Description : An OP-AMP can be classified as  1.Linear amplifier 2.Low - Rin amplifier 3.Positive - feedback amplifier 4.RC - coupled amplifier 

Last Answer : An OP-AMP can be classified as Low - Rin amplifier

Description : In op-amp operation, Common Mode Rejection Ratio (CMRR)

Last Answer : In op-amp operation, Common Mode Rejection Ratio (CMRR) is desired to be high

Description : Why open loop OP-AMP configurations are not used in linear applications?

Last Answer : The open loop gain of the op-amp is not a constant and it varies with changing the temperature and variations in power supply.Also the bandwidth of the open loop op-amp is negligibly small.For this reasons open loop OP-AMP configurations are not used in linear applications.

Description : An operational amplifier has an open loop gain of 200,000. Its output exhibits saturation at 10V. The threshold differential voltage of the amplifier is  A) 25 micro-volt B) 50 micro-volt C) 5 Volts D) 10 volts

Last Answer : An operational amplifier has an open loop gain of 200,000. Its output exhibits saturation at 10V. The threshold differential voltage of the amplifier is 50 micro-volt

Description : Describe how Op-Amp is used as adder using circuit diagram and output voltage equation.

Last Answer : Summing Amplifier Circuit In this simple summing amplifier circuit, the output voltage, ( Vout ) now becomes proportional to the sum of the input voltages, V1, V2, V3, etc. Then we can ... to the non-inverting input of the op-amp, it will produce the positive sum of the input voltages.

Description : Explain the function of sample and hold circuit by using op-amp.

Last Answer : sample and hold circuit by using op-amp The n-channel MOSFET is driven by a control voltage VC acts as a switch. The control voltage VC is applied to the gate of the MOSFET ... called sample period. The time period during which the voltage across capacitor is constant is called Hold period.

Description : The gain G of non-inverting amplifier is (a) G = − R2 R1 (b) G = 1 + R2 R1 (c) G = R2

Last Answer : (b) G = 1 + R2 R1

Description : Two non -inverting amplifiers, one having a unity gain and the other having again of twenty are made using identical operational amplifiers. As compared to the unity gain amplifier, the amplifier with gain twenty has

Last Answer : Two non -inverting amplifiers, one having a unity gain and the other having again of twenty are made using identical operational amplifiers. As compared to the unity gain amplifier, the amplifier with gain twenty has less bandwidth

Description : If the feedback factor of an amplifier is 0.1 and its gain without feedback is 40, then its gain with feedback is (a) – 13.3 (b) 200 (c) 8 (d) 10 

Last Answer : If the Feedback Factor of an amplifier is 0.1 and its gain without feedback is 40, then feedback is 40,then its gain with feedback is 8.

Description : What are the areas of application of non-linear op- amp circuits?

Last Answer : 1. Industrial instrumentation 2. Communication 3. Signal processing

Description : The signal to the circuit on card 'A0AA2' at coordinate '29Q' shown in the illustration is on the ____________. EL-0099 A. non-inverting input at pin '20' B. inverting input at pin '16' C. non-inverting input at pin '14' D. inverting input at pin '46'

Last Answer : Answer: B

Description : On which of the following factors does the sensitivity of a closed loop system to gain changes and load disturbances depend? a) Frequency b) Loop gain c) Forward gain d) All of the mentioned

Last Answer : Ans: D

Description : The characteristic equation for a closed loop system with forward gain K is s4 + 4s3 + 8s2 + 6s + K = 0. The critical gain value Kc for stability should not exceed  (a) 3.25 (b) 9.75 (c) 13.0 (d) 23.3

Last Answer : The characteristic equation for a closed loop system with forward gain K is s4 + 4s3 + 8s2 + 6s + K = 0. The critical gain value Kc for stability should not exceed  (a) 3.25 (b) 9.75 (c) 13.0 (d) 23.3

Description : In the ideal closed loop operational amplifier, the gain depends on (A) value of the series component (B) value of the feedback component (C) on the operational amplifier itself (D) both A and B

Last Answer : In the ideal closed loop operational amplifier, the gain depends on (A) value of the series component (B) value of the feedback component (C) on the operational amplifier itself (D) both A and B

Description : After drawing the Root-Locus, the closed-loop poles corresponding to a specified value of gain K can be determined from which of the following criterion ? (A) Magnitude criterion alone (B) Angle criterion alone (C) Both Magnitude and Angle criteria (D) Angle of departure and angle of arrival.

Last Answer : After drawing the Root-Locus, the closed-loop poles corresponding to a specified value of gain K can be determined from which of the following criterion ? (A) Magnitude criterion alone (B) Angle ... (C) Both Magnitude and Angle criteria (D) Angle of departure and angle of arrival.

Description : In closed loop control system, with positive value of feedback gain the overall gain of the system will

Last Answer : In closed loop control system, with positive value of feedback gain the overall gain of the system will decrease.

Description : What is Op -Amp ?

Last Answer : The operational amplifier is abbreviated as OP-Amp . This OP-Amp is a high gain direct coupled negative feedback amplifier circuit with multiple transistors. Op-Amp is a modular , multistage amplifying device with a ... of op-amp is 500 ml. Op-amp IC : A709, LM108, LM208, CA741 and CA741T.

Description : What is op amp?

Last Answer : An operational amplifier, which is often called an op-amp, is a DC-coupled high-gain electronic voltage amplifier with a differential input and, usually, a single-ended output.[1] An op-amp ... at the input terminals (ideally infinite) and low output impedance at the output terminal(s) (idea

Description : What is op amp?

Last Answer : An operational amplifier, which is often called an op-amp, is a DC-coupled high-gain electronic voltage amplifier with a differential input and, usually, a single-ended output.[1] An op-amp ... at the input terminals (ideally infinite) and low output impedance at the output terminal(s) (idea

Description : What is the type of feedback used in an op-amp Schmitt trigger?

Last Answer : The type of feedback used in an op-amp Schmitt trigger is positive feedback.

Description : What is the basic building block of an op-amp?

Last Answer : The basic building block of an op-amp is differential amplifier.

Description : What are the DC characteristics of an op-amp?

Last Answer : a. input bias current b. Input offset current c .Input offset voltage d. Thermal drift

Description : What are the AC characteristics of an op-amp?

Last Answer : a. Frequency response b. Slew rate

Description : What is compensated op-amp?

Last Answer : Op-amp, which uses a capacitor internally for compensation, is called a compensated op-amp. This op-amp has a high gain stability and low bandwidth.

Description : What is an op-amp?

Last Answer : The operational amplifier is a multi-terminal device, which is quite complex internally. An operational amplifier is a direct coupled high gain amplifier usually consisting of one or more ... as well as ac input signals and was originally designed for computing such mathematical functions.

Description : Coil of relay is connected to the A. input of op-amp B. output of op-amp C. midpoint of op-am D. anywhere in between input and ouput of op-amp

Last Answer : output of op-amp

Description : If current of 20 mA is passing through op-amp and voltage drop across series resistor is 10 V then value of resistance is A. 500Ω B. 400Ω C. 300Ω D. 200Ω

Last Answer : 500Ω

Description :  A device used to avoid the relay destroying the op-amp is A. diode B. LED C. reverse bias diode D. forward biased diode

Last Answer : reverse bias diode

Description : Number of power supplies required to get output of op-amp is A. two B. four C. six D. three

Last Answer : two

Description : Impedance of ideal op-amp is A. zero B. 1 C. infinite D. 2

Last Answer :  infinite

Description : Output resistance of an actual op-amp is A. 45Ω B. 46Ω C. 70Ω D. 75Ω

Last Answer : 75Ω

Description : Op-amp can provide maximum output current of A. 25 mAB. 30 mA C. 35 mA D. 40 mA

Last Answer :  25 mA

Description : Write transfer function of op amp as an integer.

Last Answer : The transfer function of the integer is  LAL=1/MR1cf

Description : Define CMRR of an op-amp.

Last Answer : The relative sensitivity of an op-amp to a difference signal as compared to a common – mode signal is called the common –mode rejection ratio. It is expressed in decibels. CMRR= Ad/Ac

Description : Define input offset current. State the reasons for the offset currents at the input of the op-amp.

Last Answer : The difference between the bias currents at the input terminals of the op-amp is called as input offset current. The input terminals conduct a small value of dc current to bias the input transistors.Since the input transistors cannot be made identical,there exists a difference in bias currents.

Description : Define virtual ground of a OP-Amp? 

Last Answer : A virtual ground is a ground which acts like a ground. It is a point that is at the fixed ground potential (0v),though it is not practically connected to the actual ground or common terminal of the circuit.

Description : what is meant by virtual ground in the op amp ?

Last Answer : Ans-The op amp connected in a negative feedback configuration that is the o/p connected to the inverting terminal tried to produce the same voltage at the inverting node as we applied to ... the inverting node at the ground potential and whatever the difference between these two nodes are amplified.