Answer :

Amplifier coupling is the process of connecting the output of one amplifier stage to the input of another amplifier stage to amplify the weak signal in phases. Couplings are used to gain more or less.

Related questions

Description : In the illustrated circuit, one advantage of the capacitor coupling over direct coupling is ____________. EL-0048 A. as the frequency decreased the capacitive reactance (Xc) increases B. the amplifier becomes ... of the signal while it isolates the biasing of each stage. D. good frequency response.

Last Answer : Answer: C

Description : Which of the following methods cannot be used to increase the bandwidth for cascaded RF amplifier stages? A) Wave traps in each stage B) Stagger tuning C) A shunt damping resistor across each tuned circuit D) Doubled tuned transformers with tighter coupling

Last Answer : A) Wave traps in each stage

Description : In a resistance loaded, RC coupled amplifier the dc component is blocked by A) Load resistance RL B) Coupling capacitor, CC C) RB D) The transistor.

Last Answer : B) Coupling capacitor, CC

Description : The Bandwidth of an RC-coupled amplifier is limited by: A) coupling capacitors at the low frequency end and bypass capacitors at the high frequency end B) coupling capacitors at the high frequency ... at the low frequency end and bypass as well as coupling capacitors at the high frequency end.

Last Answer : C) bypass and coupling capacitors at the low frequency end and shunt capacitors at the high frequency end and

Description : What is the most common form of coupling for an rf amplifier?

Last Answer : Transformer coupling.

Description : If current gain is required from an rf amplifier, what type of component should be used as an output coupling element?

Last Answer : A step-down transformer.

Description : What type coupling would be most useful for an audio amplifier between the first and second stages?

Last Answer : RC coupling.

Description : What type coupling is usually used to couple the output from a power amplifier?

Last Answer : Transformer coupling.

Description : What are four methods of coupling amplifier stages?

Last Answer : Direct, RC, impedance, and transformer coupling.

Description : What is the purpose of an amplifier-coupling network?

Last Answer : To transfer energy (a signal) from one stage to another.

Description : Draw the multistage amplifier circuit diagram using RC coupling. State its advantages.

Last Answer : Advantages: 1. It has a wide frequency response. 2. For coupling the resistor and the capacitor are used and which are not expensive so the cost is low. 3. The circuit is very ... a wide frequency band. 5. It is high fidelity amplifier. 6. It provides less frequency distortion.

Description : State the need and types of amplifier coupling. 

Last Answer : Need of amplifier coupling: 1.When ever large amplifier with very good impedance matching is required, a signal stage amplifier circuit will not able to amplify the signal to a large extent. 2 ... 2.Transformer coupled amplifier 3.Direct coupled amplifier 4. Inductance (LC) coupling

Description : List the types of coupling used in BJT amplifier. 

Last Answer : Types of coupling used in BJT amplifier: i. Resistance capacitance (RC)coupling ii. Impedance coupling iii. Transformer coupling iv. Direct coupling

Description : Give the different types of amplifier coupling.

Last Answer : 1. Resistance – capacitance (RC) coupling.  2. Inductance (LC) coupling.  3. Transformer coupling (TC)  4. Direct coupling (D.C.)

Description : Transformer coupling is used in class A amplifier to make it : -  a) more efficient b) less bulky c) less costly d) distortion free

Last Answer : Transformer coupling is used in class A amplifier to make it : - more efficient

Description : The purpose of a coupling capacitor in an amplifier is to:  (1) Control the output (2) Provide impedance matching (3) Provide DC isolation between amplifier and load (4) W Increase the bandwidth

Last Answer : The purpose of a coupling capacitor in an amplifier is to: Provide DC isolation between amplifier and load.

Description : One advantage of transformer coupling in transistor amplifier is that:  (1) it provides excellent frequency response (2) It is simple and less expensive than others (3) Low power supply may be used (4) High efficiency and high power output is obtained.

Last Answer : One advantage of transformer coupling in transistor amplifier is that: High efficiency and high power output is obtained.

Last Answer : For an amplifier, the coupling method which gives the highest gain is Transformer coupling.

Description : We’re watching the Wizard of Oz, and I’m wondering if there’s any truth to the story about the difficulty they had filming the movie due to the fact that the little actors playing the munchkins were so busy coupling up?

Last Answer : The last munchkin to die seemed to have said that sadly Garland’s personal problems which included drinking led to making unfortunate statements which were untrue.

Description : A locomotive of weight 100 tonnes is attached to train of wagons weighing 1000 tonnes. The locomotive pulls the wagons with a constant velocity of 36 km/hour. When the coupling between the train and wagons breaks, the wagons roll on 95 m in ... would be a.0.36 m b.0.44 m c.0.77 m. d.0.5 m e.0.66 m

Last Answer : d. 0.5 m

Description : What is the answer Two NYC metro railway cars coupling at Grand Central station.Describe the motion of the coupling card and their motion after colliding?

Last Answer : I

Description : What is a coupling reaction ?

Last Answer : : An oxidation reaction in which two or more chemicals combine to form a single product is called a coupling reaction. For example, ferrous chloride combines with chlorine to produce ferric ... Thus the process of producing ammonia gas is considered as either a coupling or synthesis reaction.

Description : What are the advantages and disadvantages of thermal coupling ?

Last Answer : Advantages (1) It is cheap and easy to build ; As a result, it is widely used. (2) Different types of heat pairs are available for measuring from low temperature to high temperature. (3) ... is not at 0 ° C temperature, correction is required. (3) Neutral temperature measurement disturbs the limit.

Description : What is the coupling reaction ?

Last Answer : : Benzene diazonium chloride ( C6H5N2Cl) reacts with phenol in mild alkaline solution ( NaOH) to form yellow azo compound. This reaction is called coupling reaction.

Description : What is the coupling of magnifiers ?

Last Answer : The method of adding two or more magnifiers is called coupling of magnifiers.

Description : Coupling reaction takes place when benzene diazonium chloride is treated with :

Last Answer : Coupling reaction takes place when benzene diazonium chloride is treated with : A. Benzaldehyde B. `alpha`-naphthol C. N, N-dimethyl aniline D. Phenol

Description : Which of the following compounds will not undergo azo coupling reaction with benzene diazonium chloride?

Last Answer : Which of the following compounds will not undergo azo coupling reaction with benzene diazonium chloride? ... B. Phenol C. Anisole D. Nitrobenzene

Description : For such kind of diazo- coupling reaction the suitable substituents P and S are respectively:

Last Answer : For such kind of diazo- coupling reaction the suitable substituents P and S are respectively: A. `-NH_(2)` and `- ... C. `-NH_(2)` and `-NHCH_(3)` D.

Description : Consider the following diazonium ion: The order of reactivity towards diazo coupling with phenol in presence of dil. NaOH:

Last Answer : Consider the following diazonium ion: The order of reactivity towards diazo coupling with phenol in presence of dil. NaOH ... ` D. `S gt R gt Q gt P`

Description : At the temperature corresponding to which of the points in Fig. `FeO` will be reduced to Fe by coupling the reaction `2Fe rarr 2Fe +O_(2)` with all of

Last Answer : At the temperature corresponding to which of the points in Fig. `FeO` will be reduced to Fe by coupling the ... A B. Point B C. Point D D. Point E

Description : carron cordon bleu 4 oven i need a thermal coupling for main oven?

Last Answer : You should be able to purchase a thermal coupling at a local home improvement store such as lowes home improvement or home depot.

Description : thermal coupling for carron cordon bleu 4 oven?

Last Answer : Maybe try a sears repair office or a used appliance sales place to find parts.

Description : Who is the Lovejoy Coupling distributors in UAE?

Last Answer : Get the best dealers of Lovejoy coupling dealers in Dubai, Lovejoy power transmission couplings supplier in Dubai, Lovejoy coupling distributors in Dubai. Machinery People is located in Dubai ... engineers employ the latest and most advanced computer techniques to develop unique solutions and design

Description : Who are the best disc coupling manufacturers?

Last Answer : Since the coupling manufacturing industry is a big one it has a lot to offer. One such company which offers a number of coupling variations is Rathi Couplings. They offer a variety of ... couplings. You can visit their blog at Rathi coupling website for more information regarding the above.

Description : The coupling of oxidation and phosphorylation in intact mitochondria: (A) Puromycin (B) Oligomycin (C) Streptomycin (D) Gentamycin

Last Answer : Answer : B

Description : In a transformer, with closed magnetic coupling between primary and secondary __ will improve: a) Efficiency b) All day efficiency c) Regulation d) None of the above

Last Answer : Ans: C

Description : Coupling and repulsion are the two states of – (1) linkage (2) chiasma (3) mutation (4) crossing over

Last Answer : (1) linkage Explanation: Genetic linkage is the tendency of genes that are located proximal to each other on a chromosome to be inherited together during meiosis. The figure below depicts the gamete composition for linked genes from coupling and repulsion crosses:

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ahead or behind ... as it rotates. This co A. hunting B. direct coupling C. peaking D. harmonic coupling

Last Answer : Answer: A

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0049 A. RC coupling B. transformer coupling C. LC coupling D. direct coupling

Last Answer : Answer: B

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0048 A. RC coupling B. transformer coupling C. LC coupling D. direct coupling

Last Answer : Answer: A

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0051 A. RC coupling B. transformer coupling C. impedance coupling D. direct coupling

Last Answer : Answer: D

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0050 A. RC coupling B. transformer coupling C. Impedance coupling D. direct coupling

Last Answer : Answer: C

Description : A shore power circuit breaker should be closed only _____________. A. when the ship's generators have been directly paralleled to those on shore B. in a shipyard C. if a quick disconnect coupling is used D. when the ship's generators have been removed from the bus

Last Answer : Answer: D

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ... windings B. direct coupling C. increase governor speed droop D. decreasing governor speed droop

Last Answer : Answer: A

Description : Modern handheld digital tachometers operate by counting light pulses returned to the unit by ______________. A. the tach generator B. either the coupling or shaft C. a small bulb attached to the shaft D. a piece of reflective tape

Last Answer : Answer: D

Description : The horizontal line which cuts across 'L1' shown in figure 'A' of the illustration indicates a/an ______________. EL-0091 A. iron core B. saturable core C. air gap D. capacitive coupling

Last Answer : Answer: B

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : Electric propulsion coupling excitation is reduced at slow speeds to ___________. A. increase speed control B. increase shaft torque C. prevent coupling overheating D. prevent coupling slippage

Last Answer : Answer: C

Description : Which one is an antenna coupling unit? A. Coupler B. Diplexer C. Lecher wire D. Duplexer

Last Answer : B. Diplexer

Description : Noise that occurs via capacitive or inductive coupling in a cable. A. Crosstalk B. Quantizing noise C. Reference noise D. Tone interference

Last Answer : A. Crosstalk