In two -wattmeter method of power measurement, if one wattmeter shows negative reading, then the power factor of the circuit is treated as (A) Unity (B) Lagging (C) Leading (D) Zero

1 Answer

Answer :

Lagging   power   factor.



Related questions

Description : Explain the effect of power factor on wattmeter reading in two wattmeter method for power measurement.

Last Answer : Effect of P.F. on Reading of Wattmeter in Two Wattmeter Method:

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : State any two disadvantages of one wattmeter method of measurement of 3 phase power.

Last Answer : State any two disadvantages of one wattmeter method of measurement of 3 phase power. Disadvantages of one wattmeter method:- 1. Only used for balanced load 2. It can not be used for ... connection then neutral point must be available 4. Delta connection must be opened to connect current coil.

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : While measuring power in a three phase load by two wattmeter method, the reading of two wattmeter are equal and opposite, when (a) load is balanced (b) power factor is unity (c) phase angle is between 60° to 90° (d) the load is purely inductive 

Last Answer :  Option (d)  Load is purely inductive 

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

Last Answer : (i) Measurement of active power in 3- phase load circuit using two- wattmeter: (ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

Description : The reading of wattmeter in no load test of induction motor gives : (A) Friction and windage loss (B) Copper losses on no load in the stator (C) Core losses (D) Sum of all losses

Last Answer : A

Description : A current carrying conductor making an electrical contact with a wiring metal conduit is indicated by a _____________. A. low switchboard wattmeter reading B. reading of 1.0 on the power factor meter C. high switchboard voltmeter reading D. totally darkened switchboard ground-detecting light

Last Answer : Answer: D

Description : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

Last Answer : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be 0.5 lagging.

Description : The instrument for measurement of flow/ velocity is________. A. Bimetallic. C) Turbine meter. B. Manometer. D) Wattmeter

Last Answer : Turbine meter

Description : A ground on a particular phase of a three-phase low voltage distribution system would be indicated by a _____________. A. high switchboard wattmeter reading B. low switchboard wattmeter reading C. dark or dim switchboard ground detecting light D. bright switchboard ground detecting light

Last Answer : Answer: C

Description : A current-carrying conductor making electrical contact with a wiring conduit will be indicated by a _____________. A. high switchboard wattmeter reading B. totally dark switchboard ground detecting light C. low switchboard wattmeter reading D. all of the above

Last Answer : Answer: B

Description : A current-carrying conductor makes accidental contact with a wiring conduit. This will be indicated by a _____________. A. low switchboard wattmeter reading B. high switchboard wattmeter reading C. darkened switchboard ground detecting lamp D. darkened switchboard synchronizing lamps

Last Answer : Answer: C

Description : Merits of two wattmeter method

Last Answer : Advantages of Two Wattmeter Method for 3-Phase Power Measurement: 1) It is used for balanced as well as unbalanced load. 2) For the star type load, it is not necessary to ... reactive volt-amperes for balanced loads also. 7) The circuit connections are independent of load connection.

Description : List one advantage and one disadvantage of one wattmeter method. 

Last Answer : Advantages:  1) Only one wattmeter is used.  2) Less number of connections.  3) Cost required is less.  Disadvantages:  1) Used only for 3- Φ balanced load and not for ... be accessible for connecting the Pressure coil.  3) Delta connection must be opened to connect current coil. 

Description : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is (A) zero (B) 0.5 (C) between zero and 0.5 (D) between 0.5 and unity

Last Answer : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is between 0.5 and unity

Description : An open occurring within the field rheostat of an AC generator can be detected by short circuiting its terminals and observing a ____________. A. negative deflection of the wattmeter pointer B. ... of the wattmeter pointer C. buildup of alternator voltage D. low, but constant alternator voltage

Last Answer : Answer: C

Description : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the A. Load is balanced B. 3 -phase load is connected to the source through 3 wires C. Load is unbalanced D. 3 -phase load is connected to the source through 4 wires

Last Answer : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the  Load is unbalanced

Description : Describe with neat circuit diagram the method of measurement of power in a High voltage, high current a.c circuit.

Last Answer : Circuit diagram:  Explanation:  The primary winding of P.T is connected across high voltage side and secondary winding is connected to pressure coil of low range wattmeter. The high voltage is ... is used Real power consumed = reading of wattmeter x ratio of C.T x ratio of P.T

Description : Which of the following conditions indicates a short circuited capacitor when checking its condition with an ohmmeter? A. The capacitor shows charging, but the final resistance reading is appreciably less ... moves quickly to the low resistance side of the scale, then slowly recedes toward infinity.

Last Answer : Answer: B

Description : A mercury (specific gravity = 13.6) manometer connected across an orificemeter fitted in a pipe shows a manometer reading of 2 cms. If the manometer liquid is changed to carbon tetrachloride (specific gravity = 1.6), then ... new manometer reading will be __________ cms. (A) 17 (B) 42 (C) 84 (D) 1.8

Last Answer : __________ cms. (A) 17

Description : State the principle of wattmeter. 

Last Answer : Working Principle of Wattmeter: It consists of two stationary coils, called current coils and one moving coil, called voltage or potential coil. The current coils are connected such that they ... experiences a force and tends to move in the direction as per Fleming's left hand rule. 

Description : State the effects of errors in dynamometer type wattmeter due to i) pc- inductance ii) pc- capacitance iii) mutual inductance iv) Connection.

Last Answer : Errors in wattmeter:  i) pc - inductance: Pressure coil inductance causes wattmeter to read more power than actual .  ii) pc-capacitance: The wattmeter reads less power.  iii) ... iv) Connection: In uncompensated wattmeter , the reading of wattmeter includes the powerloss in coils. 

Description : State any four errors that occur in dynamometer type wattmeter

Last Answer : Errors that occur in dynamometer type wattmeter: 1. Errors due to method of connection. 2. Error due to pressure coil inductance. 3. Error due to pressure coil Capacitance. 4. Error due to mutual ... Error due to eddy currents. 7. Temperature error. 8. Error due to vibration of moving system

Description : Compare CC and PC of wattmeter on the basis of:- (i) Connection (ii) Status (iii) Number of turns (iv) Gauge of wire.

Last Answer : Particulars Current coil (CC) Pressure coil (PC) Connection Connected in series with load Connected in parallel with load Status It is fixed coil in wattmeter It is moving coil in ... number of turns It is having more number of turns Gauge of wire Less More

Description : With neat diagram explain constructional details of dynamometer type wattmeter.

Last Answer : Working Principle of Wattmeter: It consists of two stationary coils, called current coils and one moving coil, called voltage or potential coil. The moving coil is mounted on the spindle, in the gap ... experiences a force and tends to move in the direction as per Fleming's left hand rule. 

Description : State various types of errors in wattmeter.

Last Answer : Types of Error in wattmeter: 1. Errors due to method of connection. 2. Error due to pressure coil inductance. 3. Error due to pressure coil Capacitance. 4. Error due to mutual inductance effect. 5. ... . Error due to eddy currents. 7. Temperature error. 8. Error due to vibration of moving system.

Description : Explain construction & working of electrodynamometer type wattmeter.

Last Answer : Electrodynamometer Type Wattmeter:  Construction: It essentially consists of the fixed and moving coil. The fixed coil is split into two equal parts which are placed close together and parallel to each other. ... hence these instruments can be used for measurement of A.C. & D.C. power.

Description : List the different errors in wattmeter & explain compensation for it.

Last Answer : Errors in Wattmeter Compensation method Error due to connection method To overcome this error, wattmeters are provided with additional compensating winding which is connected in series with ... due to friction The weight of moving system be reduced to minimum possible.

Description : Consider the following statements with regard to induction type wattmeter :  1. Can be used on both ac and dc systems.  2. Power consumption is relatively low.  3. It is accurate only at stated frequency and temperature.  Which ... /are correct ?  (a) 1 only (b) 2 only (c) 3 only (d) 1, 2 and 3

Last Answer : Consider the following statements with regard to induction type wattmeter :  1. Can be used on both ac and dc systems.  2. Power consumption is relatively low.  3. It is accurate only at stated frequency and temperature. ... correct ?  (a) 1 only (b) 2 only (c) 3 only (d) 1, 2 and 3

Description : Which one is not a correct type of wattmeter? A. Dynamometer wattmeter B. Induction wattmeter C. Electrolyte wattmeter D. Electrostatic wattmeter 

Last Answer : Electrolyte wattmeter is not a correct type of wattmeter.

Description : A wattmeter is used to determine ____________. A. the power being consumed by electrical equipment B. partial circuit resistance C. current flowing in a circuit D. voltage existing between two points in a circuit

Last Answer : Answer: A

Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : The true power indicated by the pointer movement of a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the ____________. A. power factor of the ... B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : ECE Board Exam November 1996 What is the applied power if a thermal RF wattmeter is connected to a transmitter through a variable attenuator? The wattmeter reads 84 mW when 15 dB of attenuation is used. A. 4.656 watts B. 2.656 watts C. 3.656 watts D. 2.856 watts

Last Answer : B. 2.656 watts

Description : ECE Board Exam November 1996 What is the applied power if a thermal RF wattmeter is connected to a transmitter through a variable attenuator? The wattmeter reads 84 mW when 15 dB of attenuation is used. A. 4.656 watts B. 2.656 watts C. 3.656 watts D. 2.856 watts

Last Answer : A. PAM

Description : Illustrate how can you use a single-phase wattmeter to measure 3 phase reactive power in a circuit?

Last Answer : We can measure reactive power of 3 phase circuit by dingle phase wattmeter by connecting the current coil in series with a line or load and connecting the pressure coil across the other two lines.  Reactive power = 3√ V * I * sinϕ Watts. 

Description : A portable hand-held and is very handy for determining the power consumption and power factor of individual motors and other inductive devices. a) Voltmeter and wattmeter. b) Wattmeter and power factor meter. c) Light meter and flash meter.

Last Answer : Voltmeter and wattmeter.

Description : For power measurements, what advantage does an electronic wattmeter have over an electrodynamic wattmeter?

Last Answer : Electronic wattmeters are capable of measuring high-fequency signals.

Description : To measure incident power, you must rotate the coupler detector of the wattmeter so that the arrow indicating power flow points toward which end of the transmission line?

Last Answer : Load.

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R—C series circuit, draw phasor diagram.

Last Answer : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-C series circuit, draw phasor diagram. Practical Significance In the industry environment ... autotransformer position to zero and switch OFF the supply. 8. Draw the phasor diagram.

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-L series circuit, draw phasor diagram.

Last Answer : Practical Significance In the industry environment Electrical Engineering diploma graduate are expected to measure basic parameters like voltage, frequency, time period etc. for R-L series circuits. Therefore ... /varying L. 7. Draw the phasor diagram for each of reading for verification.