Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

1 Answer

Answer :

(i) Measurement of active power in 3- phase load circuit using two- wattmeter:

electronics2electrical.com 738 -  .jpg

electronics2electrical.com 739 -  .jpg

(ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

electronics2electrical.com 741 -  .jpg

Related questions

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R—C series circuit, draw phasor diagram.

Last Answer : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-C series circuit, draw phasor diagram. Practical Significance In the industry environment ... autotransformer position to zero and switch OFF the supply. 8. Draw the phasor diagram.

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-L series circuit, draw phasor diagram.

Last Answer : Practical Significance In the industry environment Electrical Engineering diploma graduate are expected to measure basic parameters like voltage, frequency, time period etc. for R-L series circuits. Therefore ... /varying L. 7. Draw the phasor diagram for each of reading for verification.

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : Explain the effect of power factor on wattmeter reading in two wattmeter method for power measurement.

Last Answer : Effect of P.F. on Reading of Wattmeter in Two Wattmeter Method:

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : Illustrate how can you use a single-phase wattmeter to measure 3 phase reactive power in a circuit?

Last Answer : We can measure reactive power of 3 phase circuit by dingle phase wattmeter by connecting the current coil in series with a line or load and connecting the pressure coil across the other two lines.  Reactive power = 3√ V * I * sinϕ Watts. 

Description : A single phase wattmeter rated for 500 V; 5A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?

Last Answer : Answer :

Description :  Draw a neat labeled block diagram of 3-phase Electronic Energy meter.

Last Answer : Labeled diagram of 3-phase electronic energy meter:

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : List any two methods of reactive power measurement in 3 phase circuit.

Last Answer : Methods of reactive power measurement in 3 phase circuit: (i) Two single phase wattmeter method (ii) One single phase wattmeter method

Description : In power system, if a voltage controlled bus is treated as a load bus then which one of the following limits would be violated? a) Voltage b) Active power c) reactive power d) Phase angle

Last Answer : a) Voltage

Description : Explain the error occurred due to pressure coil inductance of electrodynamometer type wattmeter. How this error is compensated?

Last Answer : For power measurement assume that the pressure coil of wattmeter is purely restitive. Hence current taken by pressure coil Ipc is in phase with voltage across the pressure coil Vpc  ... inductive reactance XL the pressure coil circuit is made purely resistive and the error is eliminated.

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Description : State any two disadvantages of one wattmeter method of measurement of 3 phase power.

Last Answer : State any two disadvantages of one wattmeter method of measurement of 3 phase power. Disadvantages of one wattmeter method:- 1. Only used for balanced load 2. It can not be used for ... connection then neutral point must be available 4. Delta connection must be opened to connect current coil.

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : Draw block diagram of function generator and state the function of each block. 

Last Answer : Block Diagram of Function Generator: OR Working of Function Generator : This instrument can deliver sine, triangular & square waves with frequency range of 0.01 Hz to ... output voltage reaches a predetermined level on the negative slope of the integrator's output voltage. 

Description : Draw the block diagram of tri-vector meter. State the various measurements possible from tri-vector meter.

Last Answer : Various measurements possible from tri-vector meter are: Tri-vector meter is a measuring instrument which measures the kWh, kVArh, the kVAh of a power line. Tri-vector meter is an energy meter ... of supply such as voltage, current, power factor, active load, reactive load, apparent load etc.

Description : Describe with block diagram; the construction of single phase electronic energy meter. 

Last Answer : Construction of Single Phase Electronic Energy Meter: 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the ... The ADC converts the square wave frequency analog output to display the energy in Watt-hour.

Description : Describe the procedure for the measurement of earth resistance by using earth tester.

Last Answer : Measurement of earth resistance by using earth tester:  It is connected to earth electrode E, whose resistance is to be measured, and the other spike P and R, as shown in the ... , the deflection of the pointer will indicate directly resistance in ohm of the earth electrode under test. 

Description : Draw a neat sketch and explain the use of CT and PT for measurement of power in a single-phase circuit?

Last Answer : If wattmeter of proper range is not available or if voltage and current ranges are high we can usr CT and PT of suitable ratio. Connect the CT and PT as shown in figure. The reading of wattmeter can be multiplied by the ratio to get the actual power.   

Description : While measuring power in a three phase load by two wattmeter method, the reading of two wattmeter are equal and opposite, when (a) load is balanced (b) power factor is unity (c) phase angle is between 60° to 90° (d) the load is purely inductive 

Last Answer :  Option (d)  Load is purely inductive 

Description : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the A. Load is balanced B. 3 -phase load is connected to the source through 3 wires C. Load is unbalanced D. 3 -phase load is connected to the source through 4 wires

Last Answer : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the  Load is unbalanced

Description : The voltage control in electric supply networks in required on account of which of the following reasons ? (a) Adjustment of voltage at consumers premises within statutory limits (b) Control of ... daily and seasonal voltage variations in accordance with variations of load (d) All of the above

Last Answer : (d) All of the above

Description : The voltage of a particular bus can be controlled by controlling the a) Active power of the bus b) Reactive power of the bus c) Phase angle d) All of the above

Last Answer : b) Reactive power of the bus

Description : Draw neat labeled diagram of single phase AC locomotive showing its various equipments of power circuit and give function of each equipment used in power circuit.

Last Answer : Functions of equipment: 1) circuit breaker: disconnects the locomotive equipment from the supply in the event of fault in the equipment / loco. 2) On load tap changer, used to control the ... 6) Traction motor: operates as per the required operating characteristics to take on the traction load.

Description : Draw the power and control circuit diagram for forward — stop — Reverse type DOL starter for 3 phase induction motor.

Last Answer : Draw the power and control circuit diagram for forward — stop — Reverse type DOL starter for 3 phase induction motor.

Description : Define active power and reactive power for RLC series circuit.

Last Answer : Active Power (P): Active power (P) is given by the product of voltage, current and the cosine of the phase angle between voltage and current.  Unit: watt (W) or kilo-watt (kW) or Mega-watt ... volt-ampere-reactive (VAr), or kilo-volt-ampere-reactive (kVAr) or Mega-voltampere-reactive (MVAr) 

Description : The apparent power drawn by an A.C. circuit is 10 kVA and active power is 8 kW. The reactive power in the circuit is?

Last Answer : The apparent power drawn by an A.C. circuit is 10 kVA and active power is 8 kW. The reactive power in the circuit is 6 kVAR.

Description : Describe with suitable example; frequency measurement by Lissajous patterns on CRO. 

Last Answer : * Initially the unknown frequency signal is connected to vertical deflection plates of CRO. * Now switch of the internal sweep generator of the horizontal deflecting system. * A standard source ... explain by following example: Assume horizontal input frequency is 10 kHz for following pattern

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Description : In two -wattmeter method of power measurement, if one wattmeter shows negative reading, then the power factor of the circuit is treated as (A) Unity (B) Lagging (C) Leading (D) Zero

Last Answer : Lagging   power   factor.

Description : Explain the calibration of single phase electronic energy meter using direct loading.

Last Answer : Calibration of Single-phase Electronic Energy Meter by Direct Loading Method: The following figure shows the arrangement of calibration for single phase electronic energy meter. A phase shifter is connected for ... are taken for different values of current at different power factors. 

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : In load flow studies of a power system, a voltage control bus is specified by a) Real power and reactive power b) Reactive power and voltage magnitude c) Voltage and voltage phase angle d) Real power and voltage magnitude

Last Answer : d) Real power and voltage magnitude

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

Description : Draw and explain force or weight measurement using load cell. 

Last Answer : Description: Load cells utilize an elastic member as the primary transducer and strain gauges as secondary transducers. Strain gauges may be attached to any elastic member, on which there exists ... across the four arm Wheatstone bridge circuit, is a measure of the weight being applied.

Description : Compare CRO and DSO. State the formula for phase measurement using CRO with necessary diagram.

Last Answer : CRO DSO Directly reads analog voltage and displays it on screen. It reads the analog voltage and converts it into digital form before being displayed on the screen. ... algorithms available and ported on microprocessor which can operate on stored samples of input voltage.

Description : The voltage phasor of a circuit is 10 ∠15° V and the current phasor is 2∠–45° A. The active and reactive powers in the circuit are   (a) 20 2 W and 10 2 VAR (b) 10 W and 10 3 VAR (c) 5 W and 5 3 VAR (d) 10 3 W and – 10 VAR 

Last Answer : Angle between voltage and current ¢=15-(-45)=60° Cos60°=1/2  Active power =vicos¢=10×2×1/2=10watt Reactive power=visin¢=10×2×sin60°=20×√3/2=10√3

Description : Describe with block diagram the working of digital frequency meter.

Last Answer : Digital frequency meter: Amplifier: The signal whose frequency is to be measured is first amplified and supplied to the schmitt trigger. Schmitt Trigger: The schmitt trigger convert ... count displayed on counter  t = time interval between start and stop condition of the gate 

Description : Describe with block diagram; the principle of operation of digital storage oscilloscope.

Last Answer : The block diagram of DSO is shown above. Sampling rate may be as high as 1,00,000 samples per sencod. For such high sampling rates, a fast conversion ADC is requried. Flash ADC ... particular signal in the memory then overwritting should be stopped.This obtained by using Hold and Save button.

Description : The instrument for measurement of flow/ velocity is________. A. Bimetallic. C) Turbine meter. B. Manometer. D) Wattmeter

Last Answer : Turbine meter

Description : for Delta-Star connection of 3-phase transformer: i) Draw the connection diagram ii) List any two advantages of this connection iii) State its area of application. 

Last Answer : Disadvantages: i) In this type of connection, the secondary voltage is not in phase with the primary. Hence it is not possible to operate this connection in parallel with star-star or delta-delta ... iv) As line current is equal to phase current the conductor size of winding should be large. 

Description : (i) Draw a labelled diagram of the human female reproductive system. (ii) Enumerate the events in the ovary of a human female during (b) Luteal phase of menstrual cycle (a) Follicular phase -Biology

Last Answer : (i)Refer to page no. 43. (2) (ii) (a) Follicular phase The primary follicle in the ovary grow to become fully mature Graafian follicle. Endometrium gets thickened. The ... Luteal phase The remaining parts of ruptured Graafian follicle transforms into corpus luteum, that secretes progesterone.

Description : What is the unit of measurement of reactive power?

Last Answer : var.

Description : Describe with neat circuit diagram the method of measurement of power in a High voltage, high current a.c circuit.

Last Answer : Circuit diagram:  Explanation:  The primary winding of P.T is connected across high voltage side and secondary winding is connected to pressure coil of low range wattmeter. The high voltage is ... is used Real power consumed = reading of wattmeter x ratio of C.T x ratio of P.T

Description : The division of the reactive KVA load between paralleled AC generators is initiated by the ______________. A. prime mover governors B. voltage regulators C. phase balance relay D. proportioner

Last Answer : Answer: B

Description : List the errors occuring in single phase electronic energy meter.

Last Answer : Errors in Single Phase Electronic Energy Meter: 1) Error due to wrong sensor opeartion. 2) Error due to temperature. 3) Error due to wrong CT opeartion. 4) Error due to wrong PT opeartion. 5 ... of scaling network. 6) Error due to wrong ADC opeartion. 7) Error due to wrong Display.