How can field strength be varied in a practical dc generator?

1 Answer

Answer :

By varying the input voltage to the field coils

Related questions

Description : The most practical way to control the voltage output of an AC generator is to vary the _____________. A. number of windings B. speed of the rotating field C. strength of the rotating magnetic field D. power factor of the load

Last Answer : Answer: C

Description : How the power of the Generator can be varied?  

Last Answer : Injecting inlet steam to the prime mover can vary active power. Reactive power can vary by the Generator main field voltage variation. An excitation change PF at which load is delivered ... core of transformers, motors, generators, overhead transmission lines (capacitive), household appliances etc. 

Description : The active power of a synchronous generator can be varied mainly by (a) changing field excitation (b) changing of prime mover speed (c) both (a) and (b) (d) none of the above

Last Answer : C

Description : Give two reasons why the value of the normalized frequency (V) is varied in single mode stepindex fibers?

Last Answer : To increase performance and reduce losses caused by bending and splicing.

Description : What characteristic of a transistor is varied in a semiconductor-reactance modulator?

Last Answer : Collector-to-emitter capacitance.

Description : What characteristic of a carrier wave is varied in frequency modulation?

Last Answer : Instantaneous frequency.

Description : How is the speed of a DC motor varied?

Last Answer : To vary the speed of a DC motor we need a constant voltage power supply with a series POT resistor of higher watt rating. A Pulse Width Modulator (PWM) can be used.

Description : What are the differences between the components of a dc generator and a dc motor?

Last Answer : There are no differences.

Description : What is the purpose of a dc generator that has been modified to function as an amplidyne?

Last Answer : It can serve as a power amplifier.

Description : What is the effect of motor reaction in a dc generator?

Last Answer : A force which causes opposition to applied turning force.

Description : What component causes a generator to produce dc voltage rather than ac voltage at its output terminals?

Last Answer : A commutator

Description : Most large alternators have a small dc generator built into them. What is its purpose?

Last Answer : To provide dc current for the rotating field.

Description : The speed of a synchronous motor is varied by _____________. A. interchanging any two of the three live leads B. changing the voltage of the system C. changing the input frequency D. increasing the field excitation

Last Answer : Answer: C

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : In a dc generator why does total flux per pole decrase if the load on the machine increases even thought the field current is constsn?

Last Answer : Due to armature reaction

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : As shown in the illustration, the generator field is excited with DC current provided by ____________. EL-0016 A. conductors '1', '2' and '3' B. inductor 'L1' C. rectifier 'CR1' D. winding 'S-2'

Last Answer : Answer: C

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : If the connections for the field and the armature on a DC motor are reversed, _____________. A. the motor will run as a generator B. the motor will not run C. the direction of rotation will be the same D. the direction of rotation will be reversed

Last Answer : Answer: C

Description : An equalizing connection between two compound-wound DC generators when paralleled, serves to _____________. A. reverse the polarity of the incoming generator as the series field weakens B. automatically ... the series field of the incoming generator D. parallel the series fields of the generators

Last Answer : Answer: D

Description : DC generator voltage is decreased by cutting _____________. A. in field resistance B. out field resistance C. in armature resistance D. out armature resistance

Last Answer : Answer: A

Description : A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an _____________. A. rotor B. stator C. exciter D. armature

Last Answer : Answer: C

Description : The voltage developed by an AC generator is controlled by varying the ____________. A. speed of the prime mover B. AC excitation to the field C. DC excitation to the field D. DC excitation of the voltage regulator

Last Answer : Answer: C

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : A variable shunt, connected across the series field coils of a DC compound wound generator, to permit adjustment of the degree of compounding, is called a _____________. A. divider B. diverter C. converter D. rheostat

Last Answer : Answer: B

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes

Last Answer : Answer: B

Description : An electrical device which employs a stationary armature and a rotating electromagnetic field is used aboard ship as a ____________. A. magnetic amplifier B. ship's service alternator C. three-wire DC generator D. saturable core reactor

Last Answer : Answer: B

Description : In a diesel electric plant, raising the generator's field excitation will cause the DC propulsion motor to ________. A. increase in speed B. decrease in speed C. affect generator speed only D. affect main motor speed if done in conjunction with higher generator engine speeds

Last Answer : Answer: A

Description : Which of the following are the parts of a DC generator that convert the AC in the armature to DC in the external circuit. Are these parts the: w) field poles x) slip rings and the brushes y) commutator and the brushes z) armature and the core

Last Answer : ANSWER: Y -- COMMUTATOR AND THE BRUSHES

Description : To conduct load test on a dc shunt motor, it is coupled to a generator which is identical to the motor. The field of the generator is also connected to the same supply source as the motor. The armature of generator is ... value of this load resistance is  (A) 1.0 (B) 0.98 (C) 0.96 (D) 0.94

Last Answer : To conduct load test on a dc shunt motor, it is coupled to a generator which is identical to the motor. The field of the generator is also connected to the same supply source as the motor. ... obtain rated armature current in both motor and generator. The p.u value of this load resistance is 0.96

Description :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: -  a) 300A b) 200A c) 150A d) 37.5A

Last Answer :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: - 37.5A

Description : From which material field coils of DC generator are made of?

Last Answer : Field coils of DC generator are usually made of copper.

Description : What causes dc bias energy to be absorbed by avalanche electrons and given up to the microwave field applied to an avalanche transit-time diode?

Last Answer : The negative-resistance property.

Description : The propeller shaft speed in a turbo-electric, synchronous, propulsion drive motor is changed by varying the __________. A. turbine speed B. number of motor poles C. field strength of the generator D. field strength of the motor

Last Answer : Answer: A

Description : The amount of voltage induced in the windings of an AC generator depends mainly on _____________. A. the number of field poles energized B. the speed at which the stator windings rotate through the magnetic field C. the strength of the magnetic field D. all of the above

Last Answer : Answer: C

Description : The amount of voltage induced in the windings of an AC generator depends on ____________. A. the number of conductors in series per winding B. the speed at which the magnetic field passes across the winding C. the strength of the magnetic field D. all of the above

Last Answer : Answer: D

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : What is the effect on magnetron operation if the magnetic field strength is too high?

Last Answer : The magnetron will not oscillate.

Description : What is the effect on magnetron operation if the magnetic field strength is too high?

Last Answer : The magnetron will not oscillate.

Description : What is the term used to identify the amount of field strength required to cause the electrons to just miss the plate and return to the filament in a circular orbit?

Last Answer : The critical value of field strength

Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : In the inverting configuration, what is the voltage (for all practical purposes) at the inverting input to the operational amplifier if the input signal is a 1-volt, peak-to-peak sine wave?

Last Answer : 0 volts.

Description : Why is damping needed in a practical servo system?

Last Answer : . To minimize overshoot and/or oscillations.

Description : How is output voltage controlled in practical alternators?

Last Answer : By varying the voltage applied to the field windings.

Description : Do you have a varied taste in music?

Last Answer : Wierd al and headbangers and classical.

Description : Can you explain the difference between a prime/fixed focal length lens and one where the focal length can be varied?

Last Answer : With a zoom lens, you can change the focal length to zoom in or out (there's a proper name for it but it escapes me). With a prime lens, it's fixed - no zoom. Because prime lenses are ... a zoom.. You'd just use them differently and get slightly different results. I think Pros only use prime lenses.