In a cable the voltage stress is maximum at (a) sheath (6) insulator (e) surface of the conductor (d) core of the conductor

1 Answer

Answer :

(d) core of the conductor

Related questions

Description : In a cable, the maximum stress under operating conditions is at (a) insulation layer (b) sheath (c) armour (d) conductor surface

Last Answer : (d) conductor surface

Description : The minimum dielectric stress in a cable is at (a) armour (b) bedding (c) conductor surface (d) lead sheath

Last Answer : (d) lead sheath

Description : The electrostatic stress in underground cables is (a) same at the conductor and the sheath (b) minimum at the conductor and maximum at the sheath (c) maximum at the conductor and minimum at the sheath (d) zero at the conductor as well as on the sheath (e) none of the above

Last Answer : (c) maximum at the conductor and minimum at the sheath

Description : Solid type cables are considered unreliable beyond 66 kV because (a) insulation may melt due to higher temperature (b) skin effect dominates on the conductor (c) of corona loss between conductor and sheath material (d) there is a danger of breakdown of insulation due to the presence of voids

Last Answer : (d) there is a danger of breakdown of insulation due to the presence of voids

Description : In single core cables armouring is not done to (a) avoid excessive sheath losses (b) make it flexible (c) either of the above (d) none of the above

Last Answer : (a) avoid excessive sheath losses

Description : In a cable immediately above metallic sheath _____ is provided. (a) Earthing connection (b) Bedding (c) Armouring (d) None of the above

Last Answer : (b) Bedding

Description : Which of the following protects a cable against mechanical injury? (a) Bedding (b) Sheath (c) Armouring (d) None of the above

Last Answer : (c) Armouring

Description : If a cable of homogeneous insulation has a maximum stress of 10 kV/mm, then the dielectric strength of insulation should be (a) 5 kV/mm (b) 10 kV/mm (a) 15 kV/mm (d) 30 kV/mm

Last Answer : (b) 10 kV/mm

Description : In case of three core flexible cable the colour of the neutral is (a) blue (b) black (c) brown (d) none of the above

Last Answer : (a) blue

Description : The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No

Last Answer : (b) No

Description : PVC stands for (a) polyvinyl chloride (b) post varnish conductor (c) pressed and varnished cloth (d) positive voltage conductor (e) none of the above

Last Answer : (a) polyvinyl chloride

Description : The thickness of the layer of insulation on the conductor, in cables, depends upon (a) Reactive power (b) Power factor (c) Voltage (d) Current carrying capacity

Last Answer : (c) Voltage

Description : the classification of cables. (i) According with voltage levels. (ii) According to numbers of core.  

Last Answer : 1. Classification of cables with their voltage levels: 1. Low voltage (tension) cable/LT cable: for operating voltage 1.1 KV. 2. High voltage (tension) cable/HT cable: for operating voltage 11 KV. 3. Super ... 4. Three & half core cable. 5. Four core cable 6. Six core cable 7. Multi core cable

Description : The breakdown voltage of a cable depends on (a) presence of moisture (b) working temperature (c) time of application of the voltage (d) all of the above

Last Answer : (d) all of the above

Description : A certain cable has an insulation of relative permittivity 4. If the insulation is replaced by one of relative permittivity 2, the capacitance of the cable will become (a) one half (6) double (c) four times (d) none of the above

Last Answer : (a) one half

Description : How the required conductor size can be reduced by use of HRC fuses?

Last Answer : HRC fuse limits the peak amplitude of fault current. HRC fuse melts at prospective current but not allows circuit to pass their high rupturing capacity that is it’s kA. 

Description : Copper as conductor for cables is used as (a) annealed (b) hardened and tempered (c) hard drawn (d) alloy with chromium

Last Answer : (a) annealed

Description : In the cables, the location of fault is usually found out by comparing (a) the resistance of the conductor (b) the inductance of conductors (c) the capacitances of insulated conductors (d) all above parameters

Last Answer : (c) the capacitances of insulated conductors

Description : Is a cable is to be designed for use on 1000 kV, which insulation would you prefer ? (a) Polyvinyle chloride (b) Vulcanised rubber (c) Impregnated paper (d) Compressed SFe gas (e) none of the above

Last Answer : (d) Compressed SFe gas

Description : Capacitance grading of cable implies (a) use of dielectrics of different permeabilities (b) grading according to capacitance of cables per km length (c) cables using single dielectric in different ... introduced at different lengths to counter the effect of inductance (e) none of the above

Last Answer : (a) use of dielectrics of different permeabilities

Description : In the cables, sheaths are used to (a) prevent the moisture from entering the cable (b) provide enough strength (e) provide proper insulation (d) none of the above

Last Answer : (a) prevent the moisture from entering the cable

Description : What is the type cable used in radiation areas?

Last Answer : Mineral insulated (MI) cables. 

Description : What is the specified cable life? 

Last Answer : 50 years.  

Description : What are the purposes of cable trays? 

Last Answer : a. Avoid sagging of cables b. Give mechanical support 

Description : If a power cable and a communication cable are to run parallel the minimum distance between the two, to avoid interference, should be (a) 2 cm (b) 10 cm (c) 50 cm (d) 400 cm

Last Answer : (c) 50 cm

Description : A cable carrying alternating current has (a) hysteresis losses only (b) hysteresis and leakage losses only (c) hysteresis, leakage and copper losses only (d) hysteresis, leakage, copper and friction losses

Last Answer : (b) hysteresis and leakage losses only

Description : The insulation of the cable decreases with (a) the increase in length of the insulation (b) the decrease in the length of the insulation (c) either (a) or (b) (d) none of the above

Last Answer : (a) the increase in length of the insulation

Description : The breakdown of insulation of the cable can be avoided economically by the use of (a) inter-sheaths (b) insulating materials with different dielectric constants (c) both (a) and (b) (d) none of the above

Last Answer : (c) both (a) and (b)

Description : If the length of a cable is doubled, its capacitance (a) becomes one-fourth (b) becomes one-half (c) becomes double (d) remains unchanged

Last Answer : (c) becomes double

Description : The material for armouring on cable is usually (a) steel tape (b) galvanised steel wire (c) any of the above (d) none of the above

Last Answer : (c) any of the above

Description : The surge resistance of cable is (a) 5 ohms (b) 20 ohms (c) 50 ohms (d) 100 ohms

Last Answer : (c) 50 ohms

Description : The bedding on a cable consists of (a) Hessian cloth (b) Jute (c) Any of the above (d) None of the above

Last Answer : (c) Any of the above

Description : The insulating material for a cable should have (a) low cost (b) high dielectric strength (c) high mechanical strength (d) all of the above

Last Answer : (d) all of the above

Description : The intersheaths in the cables are used to (a) minimize the stress (b) avoid the requirement of good insulation (c) provide proper stress distribution (d) none of the above

Last Answer : (c) provide proper stress distribution

Description : The advantage of cables over overhead transmission lines is (a) easy maintenance (b) low cost (c) can be used in congested areas (d) can be used in high voltage circuits

Last Answer : (c) can be used in congested areas

Description : In cables the charging current (a) lags the voltage by 90° (b) leads the voltage by 90° (c) lags the voltage by 180° (d) leads the voltage by 180°

Last Answer : (b) leads the voltage by 90°

Description : cables are used for 132 kV lines. (a) High tension (b) Super tension (c) Extra high tension (d) Extra super voltage

Last Answer : (d) Extra super voltage

Description : What are the types of cables used in 6.6 kV and 415 V system voltages? 

Last Answer : In 6.6 kV system AC (unearthed) grade having stranded aluminium conductors cables are used. Their insulation's are as follows. 1. XLPE - Crossed linked polyethylene insulation. 2. FRLS PVC - Fire ... V grade copper or aluminium stranded cables are used. Their insulations are HR PVC and FS type. 

Description : The disadvantage with paper as insulating material is (a) it is hygroscopic (6) it has high capacitance (c) it is an organic material (d) none of the above

Last Answer : (a) it is hygroscopic

Description : The relative permittivity of rubber is (a) between 2 and 3 (b) between 5 and 6 (c) between 8 and 10 (d) between 12 and 14

Last Answer : (a) between 2 and 3

Description : ______ cable consists of an inner copper core and asecond conductingouter sheath. A) Twisted-pair B) Coaxial C) Fiber-optic D) Shielded twisted-pair

Last Answer : Coaxial

Description : Compare pin type and suspension insulators on given points: (i) Position of insulator on cross arm. (ii) Position of conductor on insulator. (iii) Reaction on cross arm. (iv) Possibility of ... Replacement cost (vi) Maximum voltage level (vii) Effect on height of supporting structure. (viii) Life 

Last Answer : S.No  Points Pin Type insulator Suspension or Disc Type insulator 1 Position of insulator on cross arm It is fixed on top of cross arm by using galvanized steel pin. So it is ... so to maintain minimum ground clearance height of pole increase.  8 Life Less More

Description : Cables for 220 kV lines are invariably (a) mica insulated (b) paper insulated (c) compressed oil or compressed gas insulated (d) rubber insulated (e) none of the above

Last Answer : (c) compressed oil or compressed gas insulated

Description : The thickness of metallic shielding on cables is usually (a) 0.04 mm (b) 0.2 to 0.4 mm (e) 3 to 5 mm (d) 40 to 60 mm

Last Answer : (a) 0.04 mm

Description : The current carrying capacity of cables in D.C. is more that in A.C. mainly due to (a) absence of harmonics (b) non-existence of any stability limit (c) smaller dielectric loss (d) absence of ripples (e) none of the above

Last Answer : (c) smaller dielectric loss

Description : Why bimetallic washers provided in aluminium copper transition joints?

Last Answer : To avoid galvanic corrosion failure.  

Description : Why 1.1 kV grade cables used for 415V?

Last Answer : To take care of the both earthed / unearthed systems.  

Description : Why armouring done?

Last Answer : For mechanical strength, protect against damage by impact of an object.  

Description : How armours /sheaths grounded? 

Last Answer : 1 core cables -- sheaths/shields/armours grounded at one end only, other end insulated to prevent the circulating current through sheaths. 3 core cables -- grounded at both ends but not including core balance CT’s, since even small induced current causes 50N operation. 

Description : What are the advantages of XLPE? 

Last Answer : a. Easy routing at heights b. Easy maintenance c. Large current (90 ºC) d. No sheath (no fatigue) e. No paper tape wrapping technique f. High dielectric strength g. Very little deformation ... i. Low tan delta and hence suits long routes j. Very light k. Good mechanical properties.