PVC stands for (a) polyvinyl chloride (b) post varnish conductor (c) pressed and varnished cloth (d) positive voltage conductor (e) none of the above

1 Answer

Answer :

(a) polyvinyl chloride

Related questions

Description : Empire tape is (a) varnished cambric (b) vulcanized rubber (c) impregnated paper (d) none of the above

Last Answer : (a) varnished cambric

Description : Which of the following insulation is used in cables? (a) Varnished cambric (b) Rubber (c) Paper (d) Any of the above

Last Answer : (d) Any of the above

Description : Which of the following statements best describes the material known as varnished cambric? A. Felted asbestos sealed with varnish. B. Cotton cloth coated with insulating varnish. C. Rubber ... Paper impregnated with mineral oil, specially wrapped with nonmetallic tape, and coated with varnish.

Last Answer : Answer: B

Description : The term PVC used in the plastic industry stands for - (1) polyvinyl chloride (2) polyvinyl carbonate (3) phosphor vanadium chloride (4) phosphavinyl chloride

Last Answer : (1) polyvinyl chloride Explanation: Polyvinyl chloride is the world's third-most widely produced synthetic plastic polymer, after polyethylene and polypropylene. About 40 million tones are produced per year.

Description : The term PVC used in the plastic industry stands for-------? A. Phosphavinyl chloride B. Phosphor vanadiu chloride C. Polyvinyl chloride (Answer) D. Polyvinyl carbobate

Last Answer : C. Polyvinyl chloride (Answer)

Description : In a cable the voltage stress is maximum at (a) sheath (6) insulator (e) surface of the conductor (d) core of the conductor

Last Answer : (d) core of the conductor

Description : The thickness of the layer of insulation on the conductor, in cables, depends upon (a) Reactive power (b) Power factor (c) Voltage (d) Current carrying capacity

Last Answer : (c) Voltage

Description : Conduit pipes are normally used to protect _____ cables. (a) unsheathed cables (b) armoured (c) PVC sheathed cables (d) all of the above

Last Answer : (a) unsheathed cables

Description : Which of the following types of insulation will begin to deteriorate FIRST as a result of the heat generated in the conductor it surrounds? A. Varnished cloth B. Rubber C. Silicon D. Asbestos

Last Answer : Answer: B

Description : The bedding on a cable consists of (a) Hessian cloth (b) Jute (c) Any of the above (d) None of the above

Last Answer : (c) Any of the above

Description : Polyvinyl chloride (PVC) (A) Is produced by Polycondensation reaction (B) Uses either emulsion or suspension polymerisation methods (C) Can be made thermosetting by adding a plasticiser (D) Softening temperature is 200°C

Last Answer : (B) Uses either emulsion or suspension polymerisation methods

Description : . Polyvinyl chloride (PVC) is (A) A thermosetting material (B) A condensation polymerisation product (C) Made by employing emulsion polymerisation (D) None of these

Last Answer : (C) Made by employing emulsion polymerisation

Description : Reactor used in the production of polyvinyl chloride (PVC) is made of (A) Nickel or glass lined steel (B) Aluminium (C) Tantalum (D) Lead

Last Answer : (A) Nickel or glass lined steel

Description : Bakelite is chemically known as (A) Polyvinyl chloride (PVC) (B) Polybutadiene (C) Phenol formaldehyde (D) Polyurethane

Last Answer : (C) Phenol formaldehyde

Description : . Polyvinyl chloride (PVC) is (A) A thermosetting material (B) A condensation polymerisation product (C) Made by employing emulsion polymerisation (D) None of these

Last Answer : (C) Made by employing emulsion polymerisation

Description : Is a cable is to be designed for use on 1000 kV, which insulation would you prefer ? (a) Polyvinyle chloride (b) Vulcanised rubber (c) Impregnated paper (d) Compressed SFe gas (e) none of the above

Last Answer : (d) Compressed SFe gas

Description : The electrostatic stress in underground cables is (a) same at the conductor and the sheath (b) minimum at the conductor and maximum at the sheath (c) maximum at the conductor and minimum at the sheath (d) zero at the conductor as well as on the sheath (e) none of the above

Last Answer : (c) maximum at the conductor and minimum at the sheath

Description : How the required conductor size can be reduced by use of HRC fuses?

Last Answer : HRC fuse limits the peak amplitude of fault current. HRC fuse melts at prospective current but not allows circuit to pass their high rupturing capacity that is it’s kA. 

Description : Copper as conductor for cables is used as (a) annealed (b) hardened and tempered (c) hard drawn (d) alloy with chromium

Last Answer : (a) annealed

Description : Solid type cables are considered unreliable beyond 66 kV because (a) insulation may melt due to higher temperature (b) skin effect dominates on the conductor (c) of corona loss between conductor and sheath material (d) there is a danger of breakdown of insulation due to the presence of voids

Last Answer : (d) there is a danger of breakdown of insulation due to the presence of voids

Description : In the cables, the location of fault is usually found out by comparing (a) the resistance of the conductor (b) the inductance of conductors (c) the capacitances of insulated conductors (d) all above parameters

Last Answer : (c) the capacitances of insulated conductors

Description : In a cable, the maximum stress under operating conditions is at (a) insulation layer (b) sheath (c) armour (d) conductor surface

Last Answer : (d) conductor surface

Description : The minimum dielectric stress in a cable is at (a) armour (b) bedding (c) conductor surface (d) lead sheath

Last Answer : (d) lead sheath

Description : The breakdown voltage of a cable depends on (a) presence of moisture (b) working temperature (c) time of application of the voltage (d) all of the above

Last Answer : (d) all of the above

Description : The advantage of cables over overhead transmission lines is (a) easy maintenance (b) low cost (c) can be used in congested areas (d) can be used in high voltage circuits

Last Answer : (c) can be used in congested areas

Description : In cables the charging current (a) lags the voltage by 90° (b) leads the voltage by 90° (c) lags the voltage by 180° (d) leads the voltage by 180°

Last Answer : (b) leads the voltage by 90°

Description : cables are used for 132 kV lines. (a) High tension (b) Super tension (c) Extra high tension (d) Extra super voltage

Last Answer : (d) Extra super voltage

Description : the classification of cables. (i) According with voltage levels. (ii) According to numbers of core.  

Last Answer : 1. Classification of cables with their voltage levels: 1. Low voltage (tension) cable/LT cable: for operating voltage 1.1 KV. 2. High voltage (tension) cable/HT cable: for operating voltage 11 KV. 3. Super ... 4. Three & half core cable. 5. Four core cable 6. Six core cable 7. Multi core cable

Description : The major constituent of laminate of safety glass, which holds the broken glass, pieces in their places during accident (and thus minimises the danger from flying glass fragments) is (A) Polyvinyl alcohol (B) Polyvinyl acetate (C) Polyvinyl butyral (D) PVC

Last Answer : (C) Polyvinyl butyral

Description : Vinyl flooring is done using __________ sheets. (A) Polypropylene (B) PVC (C) Polythene (D) Polyvinyl acetate

Last Answer : (B) PVC

Description : In case of dry spinning of polymers, the polymer solution in a volatile solvent is forced through the spinnerates into a warm air chamber, where the solvent evaporates leaving behind the polymer in the filament ... is used for __________ fibres. (A) Polythene (B) PVC (C) Rayon (D) Polyvinyl acetate

Last Answer : (B) PVC

Description : Write one application for the give dielectric material. (i) Polyvinyl Carbide(PVC) (ii) Glass (iii) Mica (iv) Cotton and Silk

Last Answer : (i) Polyvinyl Carbide(PVC):it is used in insulation of wires and cables in domestic wiring as well as in aircraft and factory wiring (any one)  (ii) Glass: 1) Alkaline glasses are used for ... with wax or varnishes are used in windings of magnet coils and small medium sized mechanics (any one) 

Description : Cables for 220 kV lines are invariably (a) mica insulated (b) paper insulated (c) compressed oil or compressed gas insulated (d) rubber insulated (e) none of the above

Last Answer : (c) compressed oil or compressed gas insulated

Description : The thickness of metallic shielding on cables is usually (a) 0.04 mm (b) 0.2 to 0.4 mm (e) 3 to 5 mm (d) 40 to 60 mm

Last Answer : (a) 0.04 mm

Description : Capacitance grading of cable implies (a) use of dielectrics of different permeabilities (b) grading according to capacitance of cables per km length (c) cables using single dielectric in different ... introduced at different lengths to counter the effect of inductance (e) none of the above

Last Answer : (a) use of dielectrics of different permeabilities

Description : In the cables, sheaths are used to (a) prevent the moisture from entering the cable (b) provide enough strength (e) provide proper insulation (d) none of the above

Last Answer : (a) prevent the moisture from entering the cable

Description : The current carrying capacity of cables in D.C. is more that in A.C. mainly due to (a) absence of harmonics (b) non-existence of any stability limit (c) smaller dielectric loss (d) absence of ripples (e) none of the above

Last Answer : (c) smaller dielectric loss

Description : PVC stands for (A) Plastic very compact (B) Polythene vinyl chloride (C) Polythene vinyl carbon (D) Polythene vanadium carbide

Last Answer : Answer: Option B

Description : What is the type cable used in radiation areas?

Last Answer : Mineral insulated (MI) cables. 

Description : Why bimetallic washers provided in aluminium copper transition joints?

Last Answer : To avoid galvanic corrosion failure.  

Description : Why 1.1 kV grade cables used for 415V?

Last Answer : To take care of the both earthed / unearthed systems.  

Description : What are the types of cables used in 6.6 kV and 415 V system voltages? 

Last Answer : In 6.6 kV system AC (unearthed) grade having stranded aluminium conductors cables are used. Their insulation's are as follows. 1. XLPE - Crossed linked polyethylene insulation. 2. FRLS PVC - Fire ... V grade copper or aluminium stranded cables are used. Their insulations are HR PVC and FS type. 

Description : Why armouring done?

Last Answer : For mechanical strength, protect against damage by impact of an object.  

Description : How armours /sheaths grounded? 

Last Answer : 1 core cables -- sheaths/shields/armours grounded at one end only, other end insulated to prevent the circulating current through sheaths. 3 core cables -- grounded at both ends but not including core balance CT’s, since even small induced current causes 50N operation. 

Description : What is the specified cable life? 

Last Answer : 50 years.  

Description : What are the advantages of XLPE? 

Last Answer : a. Easy routing at heights b. Easy maintenance c. Large current (90 ºC) d. No sheath (no fatigue) e. No paper tape wrapping technique f. High dielectric strength g. Very little deformation ... i. Low tan delta and hence suits long routes j. Very light k. Good mechanical properties. 

Description : What are the disadvantages of paper insulation? 

Last Answer : a. Absorbs moisture. b. Cable termination/sealing problems. 

Description : What are the purposes of cable trays? 

Last Answer : a. Avoid sagging of cables b. Give mechanical support 

Description : The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No

Last Answer : (b) No