Is a cable is to be designed for use on 1000 kV, which insulation would you prefer ? (a) Polyvinyle chloride (b) Vulcanised rubber (c) Impregnated paper (d) Compressed SFe gas (e) none of the above

1 Answer

Answer :

(d) Compressed SFe gas

Related questions

Description : Cables for 220 kV lines are invariably (a) mica insulated (b) paper insulated (c) compressed oil or compressed gas insulated (d) rubber insulated (e) none of the above

Last Answer : (c) compressed oil or compressed gas insulated

Description : Empire tape is (a) varnished cambric (b) vulcanized rubber (c) impregnated paper (d) none of the above

Last Answer : (a) varnished cambric

Description : If a cable of homogeneous insulation has a maximum stress of 10 kV/mm, then the dielectric strength of insulation should be (a) 5 kV/mm (b) 10 kV/mm (a) 15 kV/mm (d) 30 kV/mm

Last Answer : (b) 10 kV/mm

Description : Which of the following insulation is used in cables? (a) Varnished cambric (b) Rubber (c) Paper (d) Any of the above

Last Answer : (d) Any of the above

Description : Solid type cables are considered unreliable beyond 66 kV because (a) insulation may melt due to higher temperature (b) skin effect dominates on the conductor (c) of corona loss between conductor and sheath material (d) there is a danger of breakdown of insulation due to the presence of voids

Last Answer : (d) there is a danger of breakdown of insulation due to the presence of voids

Description : Dielectric strength of rubber is around (a) 5 kV/mm (b) 15 kV/mm (c) 30 kV/mm (d) 200 kV/mm

Last Answer : (c) 30 kV/mm

Description : Rubber is most commonly used insulation in cables. (a) Yes (b) No

Last Answer : (a) Yes

Description : In the cables, sheaths are used to (a) prevent the moisture from entering the cable (b) provide enough strength (e) provide proper insulation (d) none of the above

Last Answer : (a) prevent the moisture from entering the cable

Description : The breakdown of insulation of the cable can be avoided economically by the use of (a) inter-sheaths (b) insulating materials with different dielectric constants (c) both (a) and (b) (d) none of the above

Last Answer : (c) both (a) and (b)

Description : The insulation of the cable decreases with (a) the increase in length of the insulation (b) the decrease in the length of the insulation (c) either (a) or (b) (d) none of the above

Last Answer : (a) the increase in length of the insulation

Description : A certain cable has an insulation of relative permittivity 4. If the insulation is replaced by one of relative permittivity 2, the capacitance of the cable will become (a) one half (6) double (c) four times (d) none of the above

Last Answer : (a) one half

Description : In a cable, the maximum stress under operating conditions is at (a) insulation layer (b) sheath (c) armour (d) conductor surface

Last Answer : (d) conductor surface

Description : What are the disadvantages of paper insulation? 

Last Answer : a. Absorbs moisture. b. Cable termination/sealing problems. 

Description : Which of the following statements best describes the material known as varnished cambric? A. Felted asbestos sealed with varnish. B. Cotton cloth coated with insulating varnish. C. Rubber ... Paper impregnated with mineral oil, specially wrapped with nonmetallic tape, and coated with varnish.

Last Answer : Answer: B

Description : A cylindrical cable of core radius 1.25cm and impregnated paper insulation of thickness 2.13cm and relative permittivity 3.5. Compute the capacitance of the cable/km (in nF

Last Answer : To calculate the capacitance of the cable per kilometer, you can use the following formula: C = ε * ε0 * A / d where: C is the capacitance of the cable per kilometer (in farads) ε is ... * 10^9 = 644 nF/km So the capacitance of the cable per kilometer would be approximately 644 nanofarads.

Description : A cable of core radius 1.25cm and impregnated paper insulation of thickness 2.13cm and relative permittivity 3.5. Compute the capacitance of the cable/km(in nF) a) 195.7 b) 179.5 c) 157.9 d) 197.5

Last Answer : a) 195.7

Description : Why 1.1 kV grade cables used for 415V?

Last Answer : To take care of the both earthed / unearthed systems.  

Description : What are the types of cables used in 6.6 kV and 415 V system voltages? 

Last Answer : In 6.6 kV system AC (unearthed) grade having stranded aluminium conductors cables are used. Their insulation's are as follows. 1. XLPE - Crossed linked polyethylene insulation. 2. FRLS PVC - Fire ... V grade copper or aluminium stranded cables are used. Their insulations are HR PVC and FS type. 

Description : Cables, generally used beyond 66 kV are (a) oil filled (b) S.L. type (c) belted (d) armoured

Last Answer : (a) oil filled

Description : Pressure cables are generally not used beyond (a) 11 kV (b) 33 kV (c) 66 kV (d) 132 kV

Last Answer : (c) 66 kV

Description : High tension cables are generally used up to (a) 11kV (b) 33kV (c) 66 kV (d) 132 kV

Last Answer : (a) 11kV

Description : cables are used for 132 kV lines. (a) High tension (b) Super tension (c) Extra high tension (d) Extra super voltage

Last Answer : (d) Extra super voltage

Description : The intersheaths in the cables are used to (a) minimize the stress (b) avoid the requirement of good insulation (c) provide proper stress distribution (d) none of the above

Last Answer : (c) provide proper stress distribution

Description : The thickness of the layer of insulation on the conductor, in cables, depends upon (a) Reactive power (b) Power factor (c) Voltage (d) Current carrying capacity

Last Answer : (c) Voltage

Description : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because  (A) Cables have a low value of capacitance which draws a high ... high value of charging current (D) Cables have a low value of capacitance and initial resistance

Last Answer : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because Cables have a high value of capacitance which draws a high value of charging current

Description : PVC stands for (a) polyvinyl chloride (b) post varnish conductor (c) pressed and varnished cloth (d) positive voltage conductor (e) none of the above

Last Answer : (a) polyvinyl chloride

Description : Natural rubber is obtained from milky sap of tropical trees. (a) Yes (b) No

Last Answer : (a) Yes

Description : The relative permittivity of rubber is (a) between 2 and 3 (b) between 5 and 6 (c) between 8 and 10 (d) between 12 and 14

Last Answer : (a) between 2 and 3

Description : Capacitance grading of cable implies (a) use of dielectrics of different permeabilities (b) grading according to capacitance of cables per km length (c) cables using single dielectric in different ... introduced at different lengths to counter the effect of inductance (e) none of the above

Last Answer : (a) use of dielectrics of different permeabilities

Description : In a cable the voltage stress is maximum at (a) sheath (6) insulator (e) surface of the conductor (d) core of the conductor

Last Answer : (d) core of the conductor

Description : Which of the listed groups of electrical insulation materials is best suited for the highest operating temperatures? A. impregnated cotton and silk B. unimpregnated paper and cotton C. pure glass and quartz D. mica and porcelain with bonding agents

Last Answer : Answer: C

Description : Low tension cables are generally used up to (a) 200 V (b) 500 V (c) 700 V (d) 1000 V

Last Answer : (d) 1000 V

Description : What is the type cable used in radiation areas?

Last Answer : Mineral insulated (MI) cables. 

Description : What is the specified cable life? 

Last Answer : 50 years.  

Description : What are the purposes of cable trays? 

Last Answer : a. Avoid sagging of cables b. Give mechanical support 

Description : The breakdown voltage of a cable depends on (a) presence of moisture (b) working temperature (c) time of application of the voltage (d) all of the above

Last Answer : (d) all of the above

Description : If a power cable and a communication cable are to run parallel the minimum distance between the two, to avoid interference, should be (a) 2 cm (b) 10 cm (c) 50 cm (d) 400 cm

Last Answer : (c) 50 cm

Description : A cable carrying alternating current has (a) hysteresis losses only (b) hysteresis and leakage losses only (c) hysteresis, leakage and copper losses only (d) hysteresis, leakage, copper and friction losses

Last Answer : (b) hysteresis and leakage losses only

Description : If the length of a cable is doubled, its capacitance (a) becomes one-fourth (b) becomes one-half (c) becomes double (d) remains unchanged

Last Answer : (c) becomes double

Description : The material for armouring on cable is usually (a) steel tape (b) galvanised steel wire (c) any of the above (d) none of the above

Last Answer : (c) any of the above

Description : The surge resistance of cable is (a) 5 ohms (b) 20 ohms (c) 50 ohms (d) 100 ohms

Last Answer : (c) 50 ohms

Description : The minimum dielectric stress in a cable is at (a) armour (b) bedding (c) conductor surface (d) lead sheath

Last Answer : (d) lead sheath

Description : In case of three core flexible cable the colour of the neutral is (a) blue (b) black (c) brown (d) none of the above

Last Answer : (a) blue

Description : In a cable immediately above metallic sheath _____ is provided. (a) Earthing connection (b) Bedding (c) Armouring (d) None of the above

Last Answer : (b) Bedding

Description : The bedding on a cable consists of (a) Hessian cloth (b) Jute (c) Any of the above (d) None of the above

Last Answer : (c) Any of the above

Description : Which of the following protects a cable against mechanical injury? (a) Bedding (b) Sheath (c) Armouring (d) None of the above

Last Answer : (c) Armouring

Description : The insulating material for a cable should have (a) low cost (b) high dielectric strength (c) high mechanical strength (d) all of the above

Last Answer : (d) all of the above

Description : The disadvantage with paper as insulating material is (a) it is hygroscopic (6) it has high capacitance (c) it is an organic material (d) none of the above

Last Answer : (a) it is hygroscopic

Description : Pick out the wrong statement. (A) Polymers made of only one monomer is called homopolymer (B) Polymers made of more than one monomer is called copolymer or mixed polymer (C) Vulcanised rubber is more elastic than natural rubber

Last Answer : (A) Polymers made of only one monomer is called homopolyme

Description : Ebonite is a/an (A) Highly vulcanised rubber (B) Natural rubber (C) Unvulcanised raw rubber (D) Adhesive

Last Answer : (A) Highly vulcanised rubber