In a load flow analysis of a power system, the load connected at a  bus is represented as  
a) Constant current drawn from the bus  
b) Constant impedance connected at the bus  
c) Voltage and frequency dependent sources at the  
boss  
d) Constant real and reactive power drawn from the  bus

1 Answer

Answer :

d) Constant real and reactive power drawn from the  bus

Related questions

Description : In load flow studies of a power system, a voltage control bus is specified by a) Real power and reactive power b) Reactive power and voltage magnitude c) Voltage and voltage phase angle d) Real power and voltage magnitude

Last Answer : d) Real power and voltage magnitude

Description : In power system, if a voltage controlled bus is treated as a load bus then which one of the following limits would be violated? a) Voltage b) Active power c) reactive power d) Phase angle

Last Answer : a) Voltage

Description : What technique is used to solve load flow problems using Z-bus (Bus impedance matrix)?

Last Answer : The formulation of load flow problem using Zbus employs Diakoptics techniques which is actually the piecewise solution of the power system problem by using tearing off technique.

Description : The voltage of a particular bus can be controlled by controlling the a) Active power of the bus b) Reactive power of the bus c) Phase angle d) All of the above

Last Answer : b) Reactive power of the bus

Description : What is the need for slack bus in power flow analysis.

Last Answer : The slack/swing bus is needed to account for transmission line losses. In a power system the total power generated will be equal to sum of power consumed by loads and losses. In a power ... power are not specified for slack bus. They are estimated through the solution of load flow equations.

Description : A power system has 100 buses including 10 generator buses. For the load flow analysis using Newton-Raphson method in polar coordinates, the size of the Jacobian is a) 189x189 b) 100x100 c) 90x90 d) 180x180

Last Answer : a) 189x189

Description : In a load flow problem solved by newton-Raphson method with polar coordinates, the size of the Jactobian is 100 × 100. If there are 20 PV buses in addition to PQ buses and a slack bus, the total number of buses in the system is_____

Last Answer : 61

Description : Define voltage-controlled bus and load bus.

Last Answer : LOAD BUS A bus is called PQ bus or load bus when real and reactive components of power are specified for the bus. In a load bus the voltage is allowed to vary within permissible limits ... constant using automatic voltage regulator, we can specify constant PGi and | Vi | for these buses.

Description : Which of the following matrix is used for load flow studies? a) null matrix b) Unit matrix c) Z bus matrix d) Y bus matrix

Last Answer : d) Y bus matrix

Description : For load flow studies, what are the quantities specified at load bus are. a) P and V b) P and Q c) V and δ d) δ and Q

Last Answer : b) P and Q

Description : What is the need for load flow analysis.

Last Answer : The load flow study of a power system is essential to decide the best operation of existing system and for planning the future expansion of the system. It is also essential for designing a new power system.

Description : The value of off diagonal elements is a) sum of admittances connected at bus j b) which is connected between bus i and bus j with positive sign c) which is connected between bus i and bus j with negative sign d) sum of admittances connected at bus i

Last Answer : c) which is connected between bus i and bus j with negative sign

Description : um of the elements of row i equal to shunt admittances connected to bus i. If this summation is zero, indicates there is no a) shunt admittance b) mutual coupling c) both 1 and 2 d) none of the above

Last Answer : c) both 1 and 2

Description : When will the generator bus is treated as load bus.

Last Answer : If the reactive power of a generator bus violates the specified limits then the generator bus is treated as load bus.

Description : Specified quantities of load bus are a) P and Q b) V and δ c) P and δ d) Q and V

Last Answer : a) P and Q

Description : Determine the correctness or otherwise of the following Assertion [a] and the Reason [r]. Assertion: Fast decoupled load flow method gives approximate load flow solution because it uses several assumptions. Reason: Accuracy ... the correct reason for [a]. c) [a] is false and [r] is true.

Last Answer : c) [a] is false and [r] is true

Description : or accurate load flow calculations on large power systems, the best method is a) N-R method b) G-S method c) Decoupled method d) all of the above

Last Answer : a) N-R method

Description : Mention the various types of buses in power system with specified quantities for each bus.

Last Answer : • Load bus or PQ-bus (P and Q are specified- Voltage magnitude and angle are to be obtained) • Generator bus or voltage controlled bus or PV bus (P and V are specified- Voltage angle and Q are to be obtained)

Description : A 1000 × 1000 bus admittance matrix for an electric power system has 8000 non-zero elements. The minimum number of branches (transmission lines and transformers) in this system are _____ (up to 2 decimal places)

Last Answer : Ans: 3500.00

Description : A 4 bus power system consists of 4 transmission lines, then find the sparsity of Y bus matrix? a) 0.75 b) 0.25 c) 0.4 d) 0.5

Last Answer : b) 0.25

Description : For n bus power system size of Y bus matrix is a) n*n b) (n-1)*(n-1) c) (n-1)*(n-2) d) (n-2)*(n-2)

Last Answer : a) n*n

Description : Discuss the effect of acceleration factor in the load flow solution algorithm.

Last Answer : An acceleration factor is a value that can be used to speed up the convergence and reduce the number of required alteration in a Gauss Seidel method of power flow analysis .Very high or very ... trial and error load flow analysis. A generally recommended value of the acceleration factor is 1.6.

Description : What is the information that are obtained from a load flow study.

Last Answer : • The magnitude and phase of bus voltages, real and reactive power flowing in each line and the line losses. • The load flow solution also gives the initial conditions of the system when the transient behavior of the system is to be studied.

Description : In load flow analysis, the load connected at a bus is represented as?

Last Answer : constant real and reactive powers drawn from bus

Description : What are the four quantities that are associated with each bus in a system?

Last Answer : • Real Power • Reactive Power • Voltage magnitude • Phase angle of voltage

Description : In power system, the maximum number of buses are a) Generator buses b) Load buses c) Slack buses d) P-V buses

Last Answer : b) Load buses

Description : In a 4 bus,4×4 Y bus matrix the number of non zero elements are 12. Find the number of transmission lines? a) 8 b) 4 c) 2 d) 5

Last Answer : b) 4

Description : Which of the following quantities are to be calculated for generator bus a) P and V b) V and δ c) δ and Q d) Q and P

Last Answer : c) δ and Q

Description : If sparsity of a 5 bus transmission line is 0.4. Find the number of transmission lines? a) 6 b) 5 c) 4 d) 3

Last Answer : b) 5

Description : Normally Z bus matrix is a a) null matrix b) sparse matrix c) full matrix d) unit matrix

Last Answer : full matrix

Description : Explain Flat Voltage start.

Last Answer : In iterative methods of load flow solution, the initial voltages of all buses except slack bus are assumed as 1+j0 p.u. This is referred to as flat voltage start.

Description : A network containing 50 buses in which 10 are the voltage control buses, 6 are the generator buses. Find the size of the Jacobian matrix. a) 84*84 b) 83*83 c) 34*34 d) 33*33

Last Answer : b) 83*83

Description : Advantage of Gauss-Seidel method is a) applicable for large power system network b) calculation time for each iteration is less c) number of iterations are less d) all of the above

Last Answer : b) calculation time for each iteration is less

Description : What will be the reactive power and bus voltage whan the generator bus is treated as load bus.

Last Answer : When the generator bus is treated as load bus, the reactive power of the bus is equated to the limit it has violated, and the previous iteration value of bus voltage is used for calculating current iteration value.

Description : What are the advantages of FDLF method.

Last Answer : FDLF method is faster, simple to program, more reliable and requires less memory than NR load flow method. FDLF method requires more iteration than N-R method, but requires less time per iteration.

Description : What is jacobian matrix?

Last Answer : The Jacobian matrix gives the linearized relationship between small changes in voltage angle or voltage magnitude with a small changes in real and reactive power.

Description : What are the disadvantages of NR method.

Last Answer : • The programming is more complex. • The memory requirement is more. • Computational time per iteration is higher due to large number of calculations per iteration.

Description : Mention any three advantages of N-R method over G-S method.

Last Answer : • The N-R method has quadratic convergence characteristic and so convergence faster than G-S method. • The number of iterations for convergence is independent of the size of the system in N-R method. • In N-R method the convergence is not affected by the choice of slack bus.

Description : Decreasing the frequency in a capacitive circuit while maintaining a constant circuit voltage, will result in a/an _____________. A. increase in apparent power B. decrease in circuit current C. decrease in capacitive reactance D. decrease in total impedance

Last Answer : Answer: B

Description : The reactive power drawn by a motor from an AC generator is the power which is _____________. A. used to establish the magnetic field of the motor B. lost in overcoming friction in the ... by current flow through the windings D. transmitted directly through the rotor shaft to perform useful work

Last Answer : Answer: A

Description : A load with an impedance of 440 ohms is connected across the secondary of the transformer illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given

Last Answer : Answer: B

Description : A load with an impedance of 440 ohms is connected across the secondary of the device illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given

Last Answer : Answer: B

Description : Nodal Analysis with Voltage Sources dependent voltage source and two supernode

Last Answer : Nodal Analysis with Voltage Sources dependent voltage source and two supernode

Description : An electrical component is connected across a 120 volt 60 hertz AC supply. What is the current drawn by the component if the impedance is 200 ohms? A. 0.01 amperes B. 0.60 amperes C. 1.67 amperes D. 100 amperes

Last Answer : Answer: B

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : Transmission lines when connected to antenna have A. capacitive load B. resistive load whose resistance is less than characteristics impedance C. resistive load at the resonant frequency D. resistive load whose resistance is greater than the characteristic impedance of the line

Last Answer : C. resistive load at the resonant frequency

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : You are attempting to parallel two AC generators and the synchroscope pointer stops at a position other than 0°. If you close the circuit breaker at this moment _____________. A. the incoming ... hazardous condition will be created by the incoming machine being at a higher frequency than the bus

Last Answer : Answer: C

Description : As shown in the illustration, the function of the switch labeled 'PFSW' is to determine the ______________. EL-0003 A. bus frequency B. reactive volt amperes of the bus C. frequency of either generator D. power factor of either generator

Last Answer : Answer: D