Description : The diameter of the stirrups according to IS : 456-2000 should not be less than [ A ] 5 mm [ B ] 6 mm [ C ] 8 mm [ D ] 10 mm
Last Answer : [ B ] 6 mm
Description : According to IS: 456 -2000, the spacing of links in a Column should be less than [ A ] 16 x diameter of smallest longitudinal bar [ B ] 24 x diameter of smallest longitudinal bar [ C ] 48 x diameter of smallest longitudinal bar [ D ] 48 x diameter of greatest longitudinal bar
Last Answer : [ A ] 16 x diameter of smallest longitudinal bar
Description : According to IS:456-2000, the minimum slenderness ratio for a short column is [ A ] Less than 12 [ B ] Between 12 and 18 [ C ] Less than 18 [ D ] Must be greater than 18
Last Answer : [ A ] Less than 12
Description : According to IS: 456-2000 Maximum spacing of shear reinforcement in no case shall not exceed [ A ] 250 mm [ B ] 300 mm [ C ] 350 mm [ D ] 450 mm
Last Answer : [ B ] 300 mm
Description : According to IS:456-2000, the minimum eccentricity in no case [ A ] Shall be not less than 20mm [ B ] Shall be not greater than 30mm [ C ] Shall be 20mm-30mm [ D ] None of the above
Last Answer : [ A ] Shall be not less than 20mm
Description : Permissible width of crack at the surface of concrete for „moderate‟ environmental conditions according to IS : 456-2000 is [ A ] 0.1 mm [ B ] 0.2 mm [ C ] 0.3 mm [ D ] 0.4 mm
Last Answer : [ B ] 0.2 mm
Description : According to IS:456-2000, the maximum allowable crack width (in mm) for mild type of environmental condition [ A ] 0.1 [ B ] 0.2 [ C ] 0.25 [ D ] 0.3
Last Answer : [ D ] 0.3
Description : According to IS: 456-2000 spacing of vertical stirrups for shear reinforcement has been limited to [ A ] 0.75 d [ B ] 450 mm [ C ] lesser of 0.75 d or 300 mm [ D ] lesser of 0.75d or 450 mm
Last Answer : [ C ] lesser of 0.75 d or 300 mm
Description : According to IS:456, the diameter of the helices in circular a column shall be at least [ A ] The diameter of longitudinal steel [ B ] One-half the diameter of longitudinal steel [ C ] One-fourth the diameter of longitudinal steel [ D ] Three-fourth the diameter of longitudinal steel
Last Answer : [ C ] One-fourth the diameter of longitudinal steel
Description : According to IS 456, minimum slenderness ratio for a short concrete column is (a) Less than 12 (b) Between 12 and 18 (c) Between 18 and 24 (d) More than 24
Last Answer : (a) Less than 12
Description : The minimum diameter of longitudinal bars in a column is (A) 6 mm (B) 8 mm (C) 12 mm (D) 16 mm
Last Answer : Answer: Option C
Description : Nominal cover for M30 grade concrete in moderate exposure is (as per IS:456-2000) [ A ] 20 mm [ B ] 30 mm [ C ] 45 mm [ D ] 50 mm
Last Answer : [ B ] 30 mm
Description : The diameter of longitudinal bars of a column should never be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm
Last Answer : Answer: Option D
Description : If the average bending stress is 6 kg/cm2 for M 150 grade concrete, the length of embedment of a bar of diameter d according to I.S. 456 specifications, is (A) 28 d (B) 38 d (C) 48 d (D) 58 d
Description : As per IS: 456-2000, the maximum size of aggregate is [ A ] 1/4 of maximum thickness of member [ B ] 1/4 of minimum thickness of member [ C ] 1/5 of maximum thickness of member [ D ] 1/5 of minimum thickness of member
Last Answer : [ B ] 1/4 of minimum thickness of member
Description : Which of the following method that is used to taken into account the slenderness effect of columns according to IS:456 - 2000 [ A ] Reduction coefficient method [ B ] Slenderness method [ C ] Moment magnification method [ D ] None of the above
Last Answer : [ A ] Reduction coefficient method
Description : According to IS: 456-2000 the ultimate moment of resistance of a slab for Fe - 415 HYSD bars is; [ A ] Mu = 0.138 fck bd2 [ B ] Mu = 0.145 fck bd2 [ C ] Mu = 0.152 fck bd2 [ D ] Mu = 0.165 fck bd2
Last Answer : [ A ] Mu = 0.138 fck bd2
Description : According to IS: 456-2000, the span/overall depth ratio for a continuous two-way slab in order to control deflection is given by [ A ] 20 [ B ] 28 [ C ] 32 [ D ] 40
Last Answer : [ C ] 32
Description : The span/over all depth ratio for a simply supported two-way slab according to IS : 456- 2000 is given by [ A ] 20 [ B ] 28 [ C ] 32 [ D ] 40
Last Answer : [ B ] 28
Description : According to IS : 456-2000, clause 39.4, stirrups should be provided for a shear of [ A ] at least 75% [ B ] at least 50% [ C ] at least 25 % [ D ] none of the above.
Last Answer : [ B ] at least 50%
Description : According to IS:456-2000, Limiting value of yield strain for Fe250grade steel is [ A ] 0.031 [ B ] 0.0031 [ C ] 0.038 [ D ] 0.0038
Last Answer : [ B ] 0.0031
Description : According to IS: 456-2000, limiting value of yield strain for Fe415 grade steel is [ A ] 0.031 [ B ] 0.0031 [ C ] 0.038 [ D ] 0.0038
Last Answer : [ D ] 0.0038
Description : According to IS:456-2000, the total acid soluble chlorides in concrete is restricted to________ of concrete [ A ] 0.2 kg/m3 [ B ] 0.4 kg/m3 [ C ] 2 kg/m3 [ D ] 4 kg/m3
Last Answer : [ B ] 0.4 kg/m3
Description : According to IS: 456-2000, the maximum cement content exclusive of admixtures is [ A ] 200 kg/m3 [ B ] 300 kg/m3 [ C ] 450 kg/m3 [ D ] 550 kg/m3
Last Answer : [ C ] 450 kg/m3
Description : According to IS:456-2000, the following type of environments are considered for durability of concrete [ A ] two [ B ] four [ C ] five [ D ] six
Last Answer : [ C ] five
Description : According to IS:456-2000, Limiting value of yield strain for Fe250 grade steel is [ A ] 0.031 [ B ] 0.0031 [ C ] 0.038 [ D ] 0.0038
Description : For a longitudinal reinforcing bar in a column, the minimum cover shall neither be less than the diameter of bar nor less than (A) 15 mm (B) 25 mm (C) 30 mm (D) 40 mm
Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four
Description : Select the incorrect statement from the following [ A ] Reinforcing bars in a column should not be less than 12 mm in diameter [ B ] The number of longitudinal bars in a circular column should not ... The minimum percentage of longitudinal steel in columns should be 0.8% [ D ] None of the above
Last Answer : [ B ] The number of longitudinal bars in a circular column should not exceed four
Description : Minimum cover to longitudinal steel in a column should be (if the diameter of bar, Ø> 12mm) [ A ] 25 mm [ B ] 30 mm [ C ] 40 mm [ D ] 50 mm
Last Answer : [ C ] 40 mm
Description : As per 1S: 456-2000, minimum grade of concrete in seat water constructions is [ A ] M20 [ B ] M25 [ C ] M30 [ D ] M50
Last Answer : [ C ] M30
Description : Minimum grade of concrete for R.C.C. should be _________ , as per IS. 456-2000 [ A ] M10 [ B ] M14 [ C ] M20 [ D ] M25
Last Answer : [ C ] M20
Description : If the diameter of longitudinal bars of a square column is 16 mm, the diameter of lateral ties should not be less than (A) 4 mm (B) 5 mm (C) 6 mm (D) 8 mm
Last Answer : Answer: Option B
Description : State the requirement of good form work and state the stripping time of form work as per IS 456-2000. i) Slab ii) Beam iii) Column with labelling on sketch.
Last Answer : Requirement of good form work: 1. It should be strong enough to resist the weight of concrete, workers and machinery. 2. It should be economical compared to total cost of construction. 3. It should be possible ... arch of span more than 6m - 21 days iii) Column: Vertical formwork - 16 to 24 hours
Description : According to the recommendations of IS : 456-1978, the expansion joints (A) Are provided where plane changes abruptly (B) Are provided to ensure minimum resistance (C) Do not carry reinforcement across them (D) All the above
Description : According to IS:456 minimum cement content inclusive of admixtures is [ A ] 200 kg/m3 [ B ] 300 kg/m3 [ C ] 450 kg/m3 [ D ] 550 kg/m3
Last Answer : [ B ] 300 kg/m3
Description : The difference in the reservoir level and the lowest point of the water mains is 180 m. The expected pressure due to water hammer is 7.5 kg/cm2 in a pressure conduit of diameter 1 m. Assuming the efficiency of the ... , is (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm
Last Answer : (C) 20 mm
Description : An R.C.C. column of 30 cm diameter is reinforced with 6 bars 12 mm placed symmetrically along the circumference. If it carries a load of 40, 000 kg axially, the stress is (A) 49.9 kg/cm2 (B) 100 kg/cm2 (C) 250 kg/cm2 (D) 175 kg/cm
Last Answer : Answer: Option A
Description : Minimum clear cover (in mm) to the main steel bars in slab, beam, column and footing respectively, are (a) 10, 15, 20 and 25 (b) 15, 25, 40 and 75 (c ) 20, 25, 30 and 40 (d) 20, 35, 40 and 75
Last Answer : (b) 15, 25, 40 and 75
Description : The diameter of ties in a column should be (A) More than or equal to one fourth of diameter of main bar (B) More than or equal to 5 mm (C) More than 5 mm but less than one-fourth of diameter of main bar (D) More than 5 mm and also more than one-fourth of diameter of main bar
Description : As per IS: 456-2000, recommended value for standard deviation for concrete mix from M30 to M50 is [ A ] 1 N/mm2 [ B ] 2 N/mm2 [ C ] 4 N/mm2 [ D ] 5 N/mm2
Last Answer : [ D ] 5 N/mm2
Description : A spring of mean radius 40 mm contains 8 action coils of steel (N = 80000 N/mm2 ), 4 mm in diameter. The clearance between the coils being 1 mm when unloaded, the minimum compressive load to remove the clearance, is (A) 25 N (B) 30 N (C) 35 N (D) 40 N
Last Answer : (C) 35 N
Description : As per IS: 456-2000, modulus of elasticity of concrete (in N/mm2) is given by [ A ] 5700 vfCK [ B ] 5000 vfCK [ C ] 3700 vfCK [ D ] 3000 vfCK
Last Answer : [ B ] 5000 vfCK