For a longitudinal reinforcing bar in a column, the minimum cover shall neither be less than the
diameter of bar nor less than
(A) 15 mm
(B) 25 mm
(C) 30 mm
(D) 40 mm

1 Answer

Answer :

Answer: Option D

Related questions

Description : Minimum cover to longitudinal steel in a column should be (if the diameter of bar, Ø> 12mm) [ A ] 25 mm [ B ] 30 mm [ C ] 40 mm [ D ] 50 mm

Last Answer : [ C ] 40 mm

Description : The minimum thickness of the cover at the end of a reinforcing bar should not be less than twice the diameter of the bar subject to a minimum of (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm

Last Answer : Answer: Option D

Description : The minimum cover in a slab should neither be less than the diameter of bar nor less than (A) 10 mm (B) 15 mm (C) 25 mm (D) 13 mm

Last Answer : Answer: Option B

Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four

Last Answer : Answer: Option D

Description : Select the incorrect statement from the following [ A ] Reinforcing bars in a column should not be less than 12 mm in diameter [ B ] The number of longitudinal bars in a circular column should not ... The minimum percentage of longitudinal steel in columns should be 0.8% [ D ] None of the above

Last Answer : [ B ] The number of longitudinal bars in a circular column should not exceed four

Description : Minimum clear cover (in mm) to the main steel bars in slab, beam, column and footing respectively, are (a) 10, 15, 20 and 25 (b) 15, 25, 40 and 75 (c ) 20, 25, 30 and 40 (d) 20, 35, 40 and 75

Last Answer : (b) 15, 25, 40 and 75

Description : The minimum clear cover for R.C.C. columns shall be (A) Greater of 40 mm or diameter (B) Smaller of 40 mm or diameter (C) Greater of 25 mm or diameter (D) Smaller of 25 mm or diameter

Last Answer : Answer: Option C

Description : The clear cover in a simply supported slab should not be less than the diameter of the reinforcing bar (a) Correct (b) Incorrect’ (c) Not known (d) None of these

Last Answer : (a) Correct

Description : The spacing of transverse reinforcement of column is decided by the following consideration. (A) The least lateral dimension of the column (B) Sixteen times the diameter of the smallest longitudinal ... column (C) Forty-eight times the diameter of transverse reinforcement (D) All the above

Last Answer : Answer: Option D

Description : The minimum diameter of longitudinal bars in a column is (A) 6 mm (B) 8 mm (C) 12 mm (D) 16 mm

Last Answer : Answer: Option C

Description : Minimum pitch of transverse reinforcement in a column is (A) The least lateral dimension of the member (B) Sixteen times the smallest diameter of longitudinal reinforcement bar to be tied (C) Forty-eight times the diameter of transverse reinforcement (D) Lesser of the above three values

Last Answer : Answer: Option D

Description : The diameter of longitudinal bars of a column should never be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm

Last Answer : Answer: Option D

Description : If the diameter of longitudinal bars of a square column is 16 mm, the diameter of lateral ties should not be less than (A) 4 mm (B) 5 mm (C) 6 mm (D) 8 mm

Last Answer : Answer: Option B

Description : According to IS: 456 -2000, the spacing of links in a Column should be less than [ A ] 16 x diameter of smallest longitudinal bar [ B ] 24 x diameter of smallest longitudinal bar [ C ] 48 x diameter of smallest longitudinal bar [ D ] 48 x diameter of greatest longitudinal bar

Last Answer : [ A ] 16 x diameter of smallest longitudinal bar

Description : The difference in the reservoir level and the lowest point of the water mains is 180 m. The  expected pressure due to water hammer is 7.5 kg/cm2  in a pressure conduit of diameter 1 m.  Assuming the efficiency of the ... , is  (A) 10 mm  (B) 15 mm  (C) 20 mm  (D) 25 mm 

Last Answer : (C) 20 mm

Description : A spring of mean radius 40 mm contains 8 action coils of steel (N = 80000 N/mm2 ), 4 mm in  diameter. The clearance between the coils being 1 mm when unloaded, the minimum compressive  load to remove the clearance, is  (A) 25 N  (B) 30 N  (C) 35 N  (D) 40 N 

Last Answer : (C) 35 N 

Description : Minimum cover for fire resistance for a given simply supported beam, when the fire rating is 1 hour--------- [ A ] 15 mm [ B ] 20 mm [ C ] 25 mm [ D ] 30 mm

Last Answer : [ B ] 20 mm

Description : Minimum cover for fire resistance for a given simply supported beam, when the fire rating is 1 hour--------- [ A ] 15 mm [ B ] 20 mm [ C ] 25 mm [ D ] 30 mm

Last Answer : [ B ] 20 mm

Description : The diameter of ties in a column should be (A) More than or equal to one fourth of diameter of main bar (B) More than or equal to 5 mm (C) More than 5 mm but less than one-fourth of diameter of main bar (D) More than 5 mm and also more than one-fourth of diameter of main bar

Last Answer : Answer: Option D

Description : The minimum cover to the ties or spirals should not be less than (A) 15 mm (B) 20 mm (C) 25 mm (D) 50 mm

Last Answer : Answer: Option C

Description : According to IS:456, the diameter of the helices in circular a column shall be at least [ A ] The diameter of longitudinal steel [ B ] One-half the diameter of longitudinal steel [ C ] One-fourth the diameter of longitudinal steel [ D ] Three-fourth the diameter of longitudinal steel

Last Answer : [ C ] One-fourth the diameter of longitudinal steel

Description : An R.C.C. column of 30 cm diameter is reinforced with 6 bars 12 mm placed symmetrically along the circumference. If it carries a load of 40, 000 kg axially, the stress is (A) 49.9 kg/cm2 (B) 100 kg/cm2 (C) 250 kg/cm2 (D) 175 kg/cm

Last Answer : Answer: Option A

Description : The Minimum bar spacing should not be less than [ A ] Diameter of the largest bar [ B ] Maximum size of aggregate [ C ] Greater of diameter of the largest bar and maximum size of aggregate [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm

Last Answer : [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm

Description : For Unbraced column, the ratio of the clear height of the column to the minimum dimension of the column shall not exceed [ A ] 30 [ B ] 40 [ C ] 50 [ D ] 60

Last Answer : [ A ] 30

Description : The minimum diameter of longitudinal steel should be [ A ] 10 mm [ B ] 12 mm [ C ] 16 mm [ D ] 20 mm

Last Answer : [ B ] 12 mm

Description : If the width of a pavement slab is 7.5 m, thickness 20 cm and working stress 1400 kg/cm2 , spacing of 10 mm tie bars for the longitudinal joint, is (A) 10 cm (B) 20 cm (C) 30 cm (D) 40 cm

Last Answer : Answer: Option C

Description : Minimum percentage of longitudinal steel in a column should not be less than [ A ] 0.60% [ B ] 0.80% [ C ] 1.00% [ D ] 1.20%

Last Answer : [ B ] 0.80%

Description : By over-reinforcing a beam, the moment of resistance can be increased not more than (A) 10 % (B) 15 % (C) 20 % (D) 25 %

Last Answer : Answer: Option D

Description : In any case, the minimum diameter of the link in a column, according to IS:456-2000 is [ A ] 5 mm [ B ] 6 mm [ C ] 8 mm [ D ] 10 mm

Last Answer : [ B ] 6 mm

Description : A steel bar 20 mm in diameter simply-supported at its ends over a total span of 40 cm carries a  load at its centre. If the maximum stress induced in the bar is limited to N/mm2, the bending  strain energy stored in the ... (A) 411 N mm  (B) 511 N mm  (C) 611 N mm  (D) 711 N mm 

Last Answer : (C) 611 N mm 

Description : If aggregates completely pass through a sieve of size 75 mm and are retained on a sieve of size 60 mm, the particular aggregate will be flaky if its minimum dimension is less than (A) 20.5 mm (B) 30.5 mm (C) 40.5 mm (D) 50.5 mm

Last Answer : Answer: Option C

Description : For determining the ultimate bearing capacity of soil, the recommended size of a square bearing plate to be used in load plate test should be 30 to 75 cm square with a minimum thickness of (A) 5 mm (B) 10 mm (C) 15 mm (D) 25 mm

Last Answer : Answer: Option D

Description : The Maximum spacing of the longitudinal bars measured long the periphery of the column should be [ A ] 250 mm [ B ] 300 mm [ C ] 400 mm [ D ] 450 mm

Last Answer : [ B ] 300 mm

Description : The diameter of main bars in R.C.C. columns, shall not be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm

Last Answer : Answer: Option D

Description : Packed column distillation is limited to the column __________ metres. (A) Height < 6 (B) Diameter < 0.6 (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : For the supply of materials for concrete, form work reinforcing and placing of concrete, removal of form work and curing of concrete, number of bar(s) required on bar chart, is (A) 1 (B) 2 (C) 3 (D) 4

Last Answer : (A) 1

Description : The diameter of the Links in column should be at least……….of the largest diameter of the longitudinal steel [ A ] One-half [ B ] Three-fourth [ C ] One eighth [ D ] One – fourth

Last Answer : [ D ] One – fourth

Description : What is the shear stress acting on the outer surface of a hollow shaft subjected to a torque of 100 Nm?(The inner and outer diameter of the shaft is 15 mm and 30 mm respectively.) a. 50.26 N/mm2 b. 40.24 N/mm2 c. 20.120 N/mm2 d. 8.74 N/mm2

Last Answer : c. 20.120 N/mm2

Description : The ratio of the diameter of reinforcing bars and the slab thickness is (A) 1/4 (B) 1/5 (C) 1/6 (D) 1/8

Last Answer : (D) 1/8

Description : The diameter of the Vicat plunger is 10 mm and its length varies from (A) 20 mm to 30 mm (B) 30 mm to 40 mm (C) 40 mm to 50 mm (D) 50 mm to 60 mm

Last Answer : Answer: Option C

Description : Maximum heat dissipation occurs from a steel wire (k = 0.5 W/m. k) of 15 mm diameter exposed to air (h = 20W/m2.k), when the insulation thickness is __________ mm. (A) 15 (B) 25 (C) 10 (D) 30

Last Answer : (B) 25

Description : The development length of bars in compression is taken as [ A ] 30 times bar diameter [ B ] 40 times bar diameter [ C ] 50 times bar diameter [ D ] 12 times bar diameter

Last Answer : [ A ] 30 times bar diameter

Description : The development length of bars in compression is taken as [ A ] 30 times bar diameter [ B ] 40 times bar diameter [ C ] 50 times bar diameter [ D ] 12 times bar diameter

Last Answer : [ A ] 30 times bar diameter

Description : Minimum spacing between horizontal parallel reinforcement of different sizes, should not be less than (A) One diameter of thinner bar (B) One diameter of thicker bar (C) Twice the diameter of thinner bar (D) None of these

Last Answer : Answer: Option B

Description : The Minimum pitch of the helical reinforcement in circular columns should be [ A ] 25 mm [ B ] 40 mm [ C ] 50 mm [ D ] 60 mm

Last Answer : [ A ] 25 mm

Description : In slump test, each layer of concrete is compacted by a steel rod 60 cm long and of 16 mm diameter for (A) 20 times (B) 25 times (C) 30 times (D) 50 time

Last Answer : Answer: Option B

Description : The eccentricity (e) of a hollow circular column, external diameter 25 cm, internal diameter 15 cm  for an eccentric load 100 t for non-development of tension, is  (A) 2.75 cm  (B) 3.00 cm  (C) 3.50 cm  (D) 4.25 cm

Last Answer : (D) 4.25 cm

Description : In order to avoid the material failure in a braced column, the clear distance between restraints should never exceed [ A ] 30 times the minimum dimensions of the column [ B ] 40 times the minimum ... 50 times the minimum dimensions of the column [ D ] 60 times the minimum dimensions of the column

Last Answer : [ D ] 60 times the minimum dimensions of the column

Description : Maximum percentage of longitudinal steel in a column should be less than [ A ] 6% [ B ] 8% [ C ] 9% [ D ] 10%

Last Answer : [ B ] 8%