The use of air-entraining agents in concretes
(a) Increases workability of concrete
(b) Decreases bleeding
(c) Decreases strength
(d) All of these

1 Answer

Answer :

(d) All of these

Related questions

Description : Admixtures which cause early setting and hardening of concrete are called (A) Workability admixtures (B) Accelerators (C) Retarders (D) Air entraining agents

Last Answer : Answer: Option B

Description : The factor which affects workability, is (A) Water content and its temperature (B) Shape and size of the aggregates (C) Air entraining agents (D) All the above

Last Answer : (D) All the above

Description : The entrained air in concrete [ A ] Increases the strength [ B ] Decreases the resistance to weathering [ C ] Increases the workability [ D ] Decreases the workability

Last Answer : [ C ] Increases the workability

Description : Workability improved by adding (A) Air-entraining agent (B) Foaming agent (C) Oily-agent (D) All the above

Last Answer : (D) All the abov

Description : The strength of concrete using air entraining cement gets reduced by (a) 5 to 10% (b) 10 to 15% (c) 15 to 20% (d) 20 to 25%

Last Answer : (b) 10 to 15%

Description : The entrained air in concrete (A) Increases workability (B) Decreases workability (C) Decreases resistance to weathering (D) Increases stress

Last Answer : Answer: Option A

Description : As compared to ordinary Portland cement, use of pozzolana cement (A) Reduces workability (B) Increases bleeding (C) Increases shrinkage (D) Increases strength

Last Answer : Answer: Option C

Description : Air entrainment in the concrete increases (A) Workability (B) Strength (C) The effects of temperature variations (D) The unit weight

Last Answer : (A) Workability

Description : An excess of flaky particles in concrete aggregates (A) Decreases the workability (B) Increases the quantity of water and sand (C) More than 15% are not desirable (D) All the above

Last Answer : Answer: Option D

Description : Increase in water content in a cement concrete (i) Increases workability (ii) Increases the strength [ A ] i [ B ] ii [ C ] both (i) and (ii) [ D ] neither (i) nor (ii)

Last Answer : [ A ] i

Description : Addition of pozzolana to cement (A) Decreases workability (B) Increases strength (C) Increases heat of hydration (D) None of these

Last Answer : Answer: Option D

Description : The continuous strain, which the concrete undergoes due to application of external loads is called [ A ] Creep [ B ] Bleeding [ C ] Workability [ D ] Segregation

Last Answer : [ A ] Creep

Description : The separation of water or water cement mixture from the freshly laid concrete is known as [ A ] Workability [ B ] Segregation [ C ] Bleeding [ D ] Creep

Last Answer : [ C ] Bleeding

Description : Pick up the correct statement from the following: (A) Continuous grading is not necessary for obtaining a minimum of air voids (B) The omission of a certain size of aggregate is shown by ... in concrete increases the workability but also increases the liability to segregation (D) All the above

Last Answer : Answer: Option D

Description : For given water content, workability decreases if the concrete aggregates contain an excess of (A) Thin particles (B) Flat particles (C) Elongated particles (D) All the above

Last Answer : (D) All the above

Description : Pick up the correct statement from the following: (A) An increase in water content must be accompanied by an increase in cement content (B) Angular and rough aggregates reduce the workability of the ... The slump of the concrete mix decreases due to an increase in temperature (D) All the above

Last Answer : Answer: Option D

Description : Pick up the correct statement from the following: (A) Water enables chemical reaction to take place with cement (B) Water lubricates the mixture of gravel, sand and cement (C) Strength of concrete structure largely depends upon its workability (D) All the above

Last Answer : (D) All the above

Description : Grading of sand causes great variation in (A) Workability of concrete (B) Strength of concrete (C) Durability of concrete (D) All the above

Last Answer : (D) All the above

Description : Proper proportioning of concrete, ensures (A) Desired strength and workability (B) Desired durability (C) Water tightness of the structure (D) All the above

Last Answer : Option D

Description : C.R.R.I. charts are used to obtain a relationship between strength of concrete and (A) Water cement ratio (B) Workability (C) Grading of aggregate (D) Fineness modulus

Last Answer : Answer: Option A

Description : Workability of concrete mix with low water cement ratio is determined by (A) Tensile strength test (B) Slump test (C) Compaction factor test (D) Flexural strength test

Last Answer : Answer: Option C

Description : Slump test for concrete is carried out, to determine (A) Strength (B) Durability (C) Workability (D) Water content

Last Answer : Answer: Option C

Description : Workability of concrete mix with low water cement ratio is determined by [ A ] Tensile strength test [ B ] Slump cone test [ C ] Compaction factor test [ D ] Flexural strength test

Last Answer : [ C ] Compaction factor test

Description : Define the following special types of concretes with its one use. i) Vacuum concrete ii) Fiber reinforced concrete iii) High performance concrete iv) Self-compacting concrete

Last Answer : The uses of special types of concretes are as follows.  i) Vacuum concrete: It is the concrete in which entrained air and excess water form concrete mix is taken out from vacuum pump, ... . large bridge and machine foundations iii. Pumped concrete for floors and slabs. iv. Pre-stressed concrete

Description : A concrete using an air entrained cement (A) Has strength less than 10% to 15% (B) Has more resistance to weathering (C) Is more plastic and workable (D) Is free from segregation and bleeding

Last Answer : Answer: Option C

Description : As the workability increases compaction factor [ A ] Decreases [ B ] Increases [ C ] Remains same [ D ] None of the above

Last Answer : [ B ] Increases

Description : Strength of concrete with passage of time (A) Increases (B) Decreases (C) Fluctuates (D) Remains constant

Last Answer : A

Description : High temperature (A) Increases the strength of concrete (B) Decreases the strength of concrete (C) Has no effect on the strength of concrete (D) None of these

Last Answer : Answer: Option B

Description : Pick up the incorrect statement from the following: (A) With passage of time, the strength of cement increases (B) With passage of time, the strength of cement decreases (C) After a ... of cement reduces to 50% (D) The concrete made with storage deteriorated cement, gains strength with time

Last Answer : Answer: Option A

Description : Select incorrect statement from the following [ A ] With passage of time, the strength of cement decreases [ B ] With passage of time, the strength of cement increases [ C ] After a period ... cement reduces to 50% [ D ] The concrete made with storage deteriorated cement; gains strength with time.

Last Answer : [ B ] With passage of time, the strength of cement increases

Description : Select the incorrect statement [ A ] R.C.C has better fire resistance than steel [ B ] R.C.C. structure is economical than steel structure [ C ] Strength of concrete decreases as age increases [ D ] R.C.C can be used for under water and marine structures

Last Answer : [ C ] Strength of concrete decreases as age increases

Description : Workability of concrete is inversely proportional to (A) Time of transit (B) water-cement ratio (C) The air in the mix (D) Size of aggregate

Last Answer : Answer: Option A

Description : Wp and Wf are the weights of a cylinder containing partially compacted and fully compacted concrete. If the compaction factor (Wp/Wf ) is 0.95, the workability of concrete is (A) Extremely low (B) Very low (C) Low (D) High

Last Answer : Option D

Description : In order to obtain the best workability of concrete, the preferred shape of aggregate is (A) Rounded (B) Elongated (C) Angular (D) All of the above

Last Answer : Answer: Option A

Description : If the slump of a concrete mix is 60 mm, its workability is (A) Very low (B) Low (C) Medium (D) High

Last Answer : Answer: Option C

Description : Higher workability of concrete is required if the structure is (A) Made with cement concrete (B) Thick and reinforced (C) Thin and heavily reinforced (D) Thick and heavily reinforced

Last Answer : Answer: Option D

Description : Pick up the correct statement from the following: (A) Higher workability indicates unexpected increase in the moisture content (B) Higher workability indicates deficiency of sand (C) If the concrete mix is dry, the slump is zero (D) All the above

Last Answer : Answer: Option D

Description : Workability of concrete is measured by (A) Vicat apparatus test (B) Slump test (C) Minimum void method (D) Talbot Richa

Last Answer : Answer: Option B

Description : Workability of concrete for a given water content is good if the aggregates, are (A) Rounded aggregate (B) Irregular aggregate (C) Angular aggregate (D) Flaky aggregate

Last Answer : Answer: Option A

Description : Pick up the correct statement from the following: (A) Segregation is necessary for a workable concrete (B) Consistency does not affect the workability of concrete (C) If the concrete mix is dry, the slump is maximum (D) None of these

Last Answer : Answer: Option D

Description : Pick up the correct statement from the following: (A) A highly absorptive aggregate reduces the workability of concrete considerably (B) The specific gravity of aggregate is important for the determination ... and porosity of an aggregate influence the property of the concrete (D) All the above

Last Answer : Answer: Option D

Description : Workability of concrete is directly proportional to (A) Aggregate cement ratio (B) Time of transit (C) Grading of the aggregate (D) All of above

Last Answer : Answer: Option C

Description : For concreting of heavily reinforced sections without vibration, the workability of concrete expressed as compacting factor should be (A) 0.75 - 0.80 (B) 0.80 - 0.85 (C) 0.85 - 0.92 (D) Above 0.92

Last Answer : Answer: Option D

Description : The basic purpose of a retarder in concrete is (A) To increase the initial setting time of cement paste in concrete (B) To decrease the initial setting time of cement paste in concrete (C) To render the concrete more water tight (D) To improve the workability of concrete mix

Last Answer : Answer: Option A

Description : The workability of concrete can be improved by adding (a) Hydrated lime (b) Fly ash (c) Calcium chloride (d) All the above

Last Answer : (d) All the above

Description : The workability of concrete is expressed by (a) Water-cement ratio (b) Slump value (c) Compaction factor (d) Both (a) and (b)

Last Answer : (d) Both (a) and (b)

Description : The workability of concrete is defined as the (a) Ease with which it can be mixed, transported and placed in position in a homogeneous state. (b) Bearing up of cohesion in a mass concrete. (c) Separation of water from the freshly mixed concrete. (d) None of these.

Last Answer : (a) Ease with which it can be mixed, transported and placed in position in a homogeneous state.

Description : The workability of concrete is mostly influenced by its [ A ] Water cement ratio [ B ] Aggregate cement ratio [ C ] Cement content [ D ] Water content

Last Answer : [ A ] Water cement ratio

Description : Workability of concrete for a given water content is good, if the aggregates are [ A ] Rounded [ B ] Irregular [ C ] Angular [ D ] Flaky

Last Answer : [ A ] Rounded

Description : Workability of a concrete – mix is determined by (i)Slump cone test (ii)Compaction factor test (iii)Vee bee test [ A ] i [ B ] ii [ C ] i and ii [ D ] i, ii and iii

Last Answer : [ D ] i, ii and iii