The input impedance of a short circuited loss less transmission line of characteristic impedance 50 Ohm is

2 Answers

Answer :

The input impedance of a short circuited loss less transmission line of characteristic impedance 50 Ohm is may be capacitive or inductive depending on the length of the line

Answer :

Capacitive

Related questions

Description : Short-circuited stubs are preferred to open-circuited stubs because thelatter are a. more difficult to make an connect b. made of a transmission line with a different characteristic impedance c. liable to radiate

Last Answer : c. liable to radiate

Description : The magnitude of the open-circuit and short circuit input impedance of a transmission line are 100 ohm and 25 ohm respectively. The characteristic impedance of line is:  (1) 25 ohm (2) 50 ohm (3) 75 ohm (4) 100 ohm

Last Answer : The magnitude of the open-circuit and short circuit input impedance of a transmission line are 100 ohm and 25 ohm respectively. The characteristic impedance of line is 25 ohm.

Description : A load of 200 ohm is used to match 300 ohm transmission line to achieve SWR=1. Find out the required characteristic impedance of a quarter of a quarter wave transformer connected directly to the load.

Last Answer : Solution :

Description : For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: (1) 100 Ω (2) 50 Ω (3) 25 Ω (4) 10 Ω

Last Answer : For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: 10 Ω

Description : The minimum impedance of a 75 ohm transmission line with a SWR of 2.5 is a) 100 b) 50 c) 25 d) 30

Last Answer : d) 30

Description : The maximum impedance of a 50 ohm transmission line with SWR of 3 is a) 50/3 b) 3/50 c) 150 d) 450

Last Answer : c) 150

Description : A 10 km long line has a characteristic impedance of 400 ohms. If line length is 100 km, the characteristic impedance is: (1) 4000 Ω (2) 400 Ω (3) 40 Ω (4) 4 Ω

Last Answer : A 10 km long line has a characteristic impedance of 400 ohms. If line length is 100 km, the characteristic impedance is: 400 Ω

Description : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

Last Answer : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of 0.02 P.U

Description : What is the input impedance of a transmission line if its characteristic impedance is 300 Ω and the load is 600 Ω? Assume a quarter wavelength section only. A. 150 kΩ B. 150 mΩ C. 150 Ω D. 2 Ω

Last Answer : C. 150 Ω

Description : Impedance inversionmaybe obtainedwith a. a short-circuited stub b. an open-circuited stub c. a quarter-wave line d. a half-wave line

Last Answer : c. a quarter-wave line

Description : When troubleshooting most electronic circuits, 'loading effect' can be minimized by using a voltmeter with a/an ___________________. A. input impedance much greater than the impedance across which the voltage ... sensitivity of less than 1000 ohms/volt D. sensitivity of more than 1000 volts/ohm

Last Answer : Answer: A

Description : If the terminating impedance is exactly equal to the characteristic impedance of the transmission line the return loss is ___________. A. zero B. one C. infinite D. None of these

Last Answer : C. infinite

Description : The parameters of Transmission line are R = 50 Ω/ km, L= 1mH/km ,C = 0.1µf/km, G = 2µV/km. calculate characteristic impedance.

Last Answer : The parameters of Transmission line are R = 50 Ω/ km, L= 1mH/km ,C = 0.1µf/km, G = 2µV/km. calculate characteristic impedance.

Description :  A single-phase transmission line of impedance j 0.8 ohm supplies a resistive load of 500 A at 300 V. The sending end power factor is?

Last Answer :  A single-phase transmission line of impedance j 0.8 ohm supplies a resistive load of 500 A at 300 V. The sending end power factor is 0.6 lagging.

Description : Which of the following characterizes a properly terminated transmission line? A. The line loss is minimum. B. The standing wave ratio is minimum. C. The input impedance is twice the load impedance. D. The standing wave ratio is one.

Last Answer : D. The standing wave ratio is one.

Description : Why is the physical length of a coaxial cable transmission line shorter than its electrical length? A. Skin effect is less pronounced in the coaxial cable B. RF energy moves slower along the ... higher in the parallel feed line D. The characteristic impedance is higher in the parallel feed line

Last Answer : B. RF energy moves slower along the coaxial cable

Description : Transmission lines when connected to antenna have A. capacitive load B. resistive load whose resistance is less than characteristics impedance C. resistive load at the resonant frequency D. resistive load whose resistance is greater than the characteristic impedance of the line

Last Answer : C. resistive load at the resonant frequency

Description : A loss less line of characteristic impedance Z0 is terminated in pure reactance of –jZ0 value. VSWR is  (1) 10 (2) 2 (3) 1 (4) Infinity

Last Answer : A loss less line of characteristic impedance Z0 is terminated in pure reactance of –jZ0 value. VSWR is Infinity.

Description : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be (A) 1835 MW (B) 2280 MW (C) 2725 MW (D) 3257 MW

Last Answer : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be 2280 MW

Description : When a transmission line has a load impedance same as that of the characteristic impedance, the line is said to be a) Parallel b) Perpendicular c) Polarized d) Matched

Last Answer : Ans: D

Description : What is the meaning of the term velocity factor of a transmission line? A. The ratio of the characteristic impedance of the line to the terminating impedance B. The index of shielding for coaxial ... The velocity of the wave on the transmission line divided by the velocity of light in a vacuum.

Last Answer : D. The velocity of the wave on the transmission line divided by the velocity of light in a vacuum.

Description : What is the meaning of the term velocity factor of a transmission line? A. The index of shielding for coaxial cable B. The velocity of the wave on the transmission line multiplied by the velocity of ... The velocity of the wave on the transmission line divided by the velocity of light in a vacuum

Last Answer : D. The velocity of the wave on the transmission line divided by the velocity of light in a vacuum

Description : Referred to the dielectric constant of a transmission line material. A. Inductance and capacitance B. Velocity factor C. Characteristic impedance D. Propagation velocity

Last Answer : B. Velocity factor

Description : In swept-frequency testing the impedance of a transmission line, what electrical characteristic is actually being measured?

Last Answer : Swr on the transmission line.

Description : A transmission line is terminated at its characteristic impedance. The reflection coefficient is  (a) 1 (b) –1 (c) 0 (d) ∞

Last Answer : A transmission line is terminated at its characteristic impedance. The reflection coefficient is  0

Description : The presence of standing waves on a transmission line is the result of A. a high level of attenuation on the line. B. terminating the line by a resistive load equal in value to the surge impedance ... input power to below its critical level. D. an impedance mismatch between the load and the line.

Last Answer : D. an impedance mismatch between the load and the line.

Description : Characteristics impedance of a transmission line is the impedance measured at the ___________ when its length is infinite. A. input B. shorted end of the line C. output D. midsection

Last Answer : A. input

Description : When an antenna of input resistance 73 ohm is connected to a 50-ohm line and if the losses are ignored then its efficiency will be nearly   (A) 0.19 (B) 0.81 (C) 0.97 (D) 1.19

Last Answer : When an antenna of input resistance 73 ohm is connected to a 50-ohm line and if the losses are ignored then its efficiency will be nearly 0.81

Description : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be

Last Answer : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be 0.2 mega ohm

Description : Find the standing wave ratio, when a load impedance of 250 ohm is connected to a 75 ohm line. a) 0.3 b) 75 c) 250 d) 3.33

Last Answer : d) 3.33

Description : The lossless line of characteristics impedance 300 Ohm is terminated in a pure resistance of 200 Ohm. The value of the standing wave ratio is  (a) 1.5 (b) 0.67 (c) 1.0 (d) 1.25

Last Answer : The lossless line of characteristics impedance 300 Ohm is terminated in a pure resistance of 200 Ohm. The value of the standing wave ratio is 1.5

Description : relay is preferred for phase fault on short transmission line. (a) Induction type (b) Reactance (c) Impedance (d) None of the above

Last Answer : (b) Reactance

Description : The reflection co-efficient at the open circuited end of a transmission line. (a) zero (b) infinity (c) unity (d) none of the above

Last Answer : (c) unity

Description : Which of the following is true for a bus impedance matrix ?  (A) It is sparse  (B) It has diagonally dominant elements  (C) It is the inverse of the bus admittance matrix  (D) Each element of it is the reciprocal of the corresponding element in admittance matrix

Last Answer : Which of the following is true for a bus impedance matrix ?  (A) It is sparse  (B) It has diagonally dominant elements  (C) It is the inverse of the bus admittance matrix  (D) Each element of it is the reciprocal of the corresponding element in admittance matrix

Description : Which of the following is not common transmission line impedance? A. 50 ohms B. 120 ohms C. 75 ohms D. 650 ohms

Last Answer : B. 120 ohms

Description : A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz supply with secondary winding open circuited. Then (A) Both eddy current and hysteresis losses decreases. (B) Both ... same but hysteresis loss increases. (D) Eddy current loss increases but hysteresis loss remains the same.

Last Answer : (A) Both eddy current and hysteresis losses decreases.

Description : Which of the following conditions indicates a short circuited capacitor when checking its condition with an ohmmeter? A. The capacitor shows charging, but the final resistance reading is appreciably less ... moves quickly to the low resistance side of the scale, then slowly recedes toward infinity.

Last Answer : Answer: B

Description : A long transmission line has considerable ……………….. effect. A) series capacitance B) shunt capacitance C) series inductance D) shunt inductance

Last Answer : Shunt Capacitance. 

Description : A single-line-to-ground fault on a overhead transmission line creates (A) voltage sag (B) voltage swell (C) over voltage (D) voltage flicker 

Last Answer : Creates  overvoltage.

Description : In an AC transmission line difference in phase of voltage at two ends of the line is due to (a) System voltage (b) Insulators (c) Resistance of line (d) Reactance of line

Last Answer : reactance of line

Description : The main consideration for operating transmission line at high voltage is (a) to increase efficiency only. (b) to reduce power loss only. (c) to increase power transmission capability only. (d) All of the above

Last Answer : to reduce power loss: this is because when power is generated, it is generated at a very low voltage but because it is going to be transported over a long distance it is needed to be increase in order to avoid losses on the way such as copper loss and Eddy loss.

Description : Effect of increase in temperature in an overhead transmission line is (a) to increase stress and length both (b) to decrease stress and length both (c) to decrease stress and increase length (d) None of the above 

Last Answer : D

Description : An overhead transmission line has a span of 260 m. The weight of the conductor is 0.68 kg/m. The maximum allowable tension in the line is 1550 kg. Maximum sag of the line should be (a) 5.8 m (b) 4.6 m (c) 2.7 m (d) 3.7 m 

Last Answer : Maximum sag = (l^2)/8c So c = T/W c = 1550/0.68 c= 2279.4 Now Maximum sag = (260^2)/8(2279.4) = 3.7 (d)

Description : What type of insulator will be used if the direction of the transmission line is to be changed?

Last Answer : Suspension type of insulator will be used if the direction of the transmission line is to be changed.

Description : Why are shunt reactors connected at the receiving end of long transmission line system: (1) To increase the terminal voltage (2) To compensate voltage rise caused by capacitive charging at light load (3) To improve power factor (4) None of these

Last Answer : Why are shunt reactors connected at the receiving end of long transmission line system: To compensate voltage rise caused by capacitive charging at light load

Description : Earth wire on EHV overhead transmission line is provided to protect the line against:

Last Answer : Earth wire on EHV overhead transmission line is provided to protect the line against: lightening surge

Description : To increase power transfer capability of a long transmission line, we should:  (1) Increase line resistance (2) Increase transmission voltage (3) Decrease line reactance (4) Both (2) & (3)

Last Answer : To increase power transfer capability of a long transmission line, we should:  (1) Increase line resistance (2) Increase transmission voltage (3) Decrease line reactance (4) Both (2) & (3)

Description : The inductance of single phase two wire power transmission line per km gets doubled when the  (a) Distance between wires is doubled  (b) Distance between the wires is increased four fold  (c) ... the wires is increased as square of the original distance  (d) Radius of the wire is doubled

Last Answer : The inductance of single phase two wire power transmission line per km gets doubled when the Distance between the wires is increased as square of the original distance 

Description : Galloping in transmission line conductors arises generally due to - (A) asymmetrical layer of ice formation (B) vortex phenomenon in light winds (C) heavy weight of line conductors (D) adoption of horizontal conductor

Last Answer : D

Description : The inductance of a power transmission line increases with (A) decrease in line length. (B) increase in conductor diameter. (C) increase in spacing between phase conductors. (D) increase in load current carried by conductors.

Last Answer : The inductance of a power transmission line increases with  increase in spacing between phase conductors.