Develop the control circuit for star-delta starter used for starting a 3 ∅ induction motor.

1 Answer

Answer :

Control Circuit for Star-Delta Starter:

1) Automatic Star-Delta Starter:

image


OR

2) Semi- automatic Star-Delta Starter:

image

Related questions

Description : Develop power and control diagram for secondary frequency acceleration starter of slip ring induction motor. 

Last Answer : Power and Control Circuit diagram for secondary frequency acceleration starter of slip ring induction motor:

Description : Describe the power and control circuit for automatic Star-Delta starter for 3-phase induction motor.

Last Answer : Power circuit: Control circuit: 

Description : Draw power and control circuit for definite time-limit starter for slip-ring induction motor. Explain its working.

Last Answer : Definite Time-limit Starter for Slip-ring Induction Motor: This starter is used for automatic control of acceleration of slip-ring induction motor at the time of starting. In this starter, the ... each phase, shorting the rotor winding terminals and final acceleration of the motor takes place. 

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : What are the advantages of star-delta starter with induction motor?

Last Answer : The main advantage of using the star delta starter is reduction of current during the starting of the motor. Starting current is reduced to 3-4 times of current of Direct online starting Hence the starting current is reduced , the voltage drops during the starting of motor in systems are reduced

Description : Why star delta starter is preferred with induction motor?

Last Answer : Star delta starter is preferred with induction motor due to following reasons: Starting current is reduced 3-4 times of the direct current due to which voltage drops and hence it causes less ... caused. In addition, starting torque is increased and it prevents the damage of motor winding.

Description : Draw and explain star delta starter for 3 phase induction motor

Last Answer : Star Delta Starter for 3 Phase Induction Motor:  Diagram Explanation: The stator winding of the motor which is designed for delta operation is connected in star during starting ... which connects stator windings in delta connection. Now each stator phase gets full line voltage VL.

Description : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Description : Disadvantages of Star-Delta Starting of Induction motor?

Last Answer : In Star-Delta starting induction motor stator is connected in star connection for starting after picking up speed it is connected to delta connection. When induction motor is connected in star connection ... . This also results in reduced starting torque (1/3 times compared to delta connection).

Description : Draw the power and control circuit diagram for forward — stop — Reverse type DOL starter for 3 phase induction motor.

Last Answer : Draw the power and control circuit diagram for forward — stop — Reverse type DOL starter for 3 phase induction motor.

Description : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be  A) 40 Nm B) 60 Nm C) 90 Nm D) 120 Nm

Last Answer : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be 40 Nm

Description : In a faceplate-type motor starter, the starting arm is held in the 'OFF' position by a/an _____________. A. cotter pin B. magnet C. electrical circuit D. strong spring

Last Answer : Answer: D

Description : Can you guys explain the advantages of frequency converter against the star delta or soft starter?

Last Answer : ¬Soft starters  A soft starter is, as you would expect, a device which ensures a soft starting of a motor. A softstarter has different characteristics to the other starting ... at rated current from zero to full speed. Frequency converters are becoming cheaper all the time.

Description : Low voltage releases as used in some shipboard motor starter and control equipment will have which of the following characteristics? A. They trip circuit contactors when the motor starts to overspeed. B. ... coil of the starter. D. They allow the motor to restart upon restoration of normal voltage.

Last Answer : Answer: D

Description : What is the Necessity of Starter of an Induction Motor?

Last Answer : Induction motors, when direct-switched, take five to seven times their full-load current and develop only 1.5 to 2.5 times their full-load torque. This initial excessive current is ... electrical equipment connected to the same lines. Hence, a starter is necessary to overcome this objection.

Description : Explain DOL starter used for 3 phase induction motor.

Last Answer : DOL Starter Used for 3 Phase Induction Motor: The direct online starter consist of overload relay (OLC), contactor, start-push button S1 (normally open), stop-push button S2 (normally ... The overload coil (OLC) protects the motor against overload and short circuit by opening the contact D.

Description : Which of the following statements is true concerning a polyphase synchronous propulsion motor? A. The motor is started as an induction motor. B. Resistance is gradually added to the rotor circuit. C. ... is held below the rated current. D. The field winding is energized for starting purposes only.

Last Answer : Answer: A

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Description : Motor starter or controller contacts may become welded together if the contacts _____________. A. open too quickly and arc B. close under excessive pressure C. open or close too quickly D. close under excessive starting current

Last Answer : Answer: D

Description : Excessive heat in an operating motor controller can result from _____________. A. a closed starter contact B. loose connections C. missing arc chutes D. low motor starting torque

Last Answer : Answer: B

Description : The rotor slots of a repulsion-type motor are generally skewed (placed nonparallel to the rotor axis) to _________. A. produce a constant starting torque B. permit a greater air gap with the starter C. permit a smaller air gap with the starter D. reduce eddy current losses

Last Answer : Answer: A

Last Answer : For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

Description : Which of the following actions must be carried out before a voltage tester can be used to test the three line fuses to a three-phase motor? A. The fuses must be removed from the circuit. B. The ... disconnected and tagged. D. Nothing need be done as long as the motor is running under a light load.

Last Answer : Answer: B

Description : The diagram shown in the illustration represents a _________. EL-0058 A. dual speed, 2-winding motor controller B. navigation running light circuit C. single phase, 2-motor selectable starter D. common fluorescent lighting circuit

Last Answer : Answer: B

Description : If a motor is wound star and you want to change to delta what should you do?

Last Answer : Open the terminal connection box. Remove the shorting link connecting the common connection (star) point of A2, B2 and C2. With the 3 phase windings marked A1A2, B1B2, C1C2, connect A2 to B1, B2 to C1 and C2 to A1.

Description : A degree of control over the speed of a slip ring induction motor can be obtained by _____________. A. adjusting governor linkage B. changing the number of phases to the motor C. inserting resistance into the stator circuit D. inserting resistance into the rotor circuit

Last Answer : Answer: D

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : Draw power and control circuit for simple plugging of induction motor.

Last Answer : Fig. Power and control circuit for simple plugging of induction motor.

Description : State the function of seal in circuit w.r.t. PLC.

Last Answer : Standard Start-Stop-Seal circuit:  * The Start-Stop-Seal circuit is as shown in figure. The power circuit consists of 3ph load (Motor) connected by a main contactor (M) to 3-phase supply. The ... * When STOP is pressed, M gets de-energized and motor gets disconnected from supply.

Description : Squirrel cage induction motor has a) Zero starting torque b) Very small starting torque c) Medium starting torque d) Very high starting torque

Last Answer : Ans: B

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : A single-phase induction motor starts, comes up to about 75% rated speed, slows down to a lower speed, and accelerates again. The problem is most likely in the ____________. A. starting winding B. running winding C. starting capacitor D. running centrifugal switch

Last Answer : Answer: B

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : Which of the following problems will most likely occur if the starting winding of a split-phase induction motor failed to cutout once the motor was in continuous operation? A. The motor will overspeed. B. The ... reduced speed. C. A time delay will stop the motor. D. The winding will burn out.

Last Answer : Answer: D

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : If an induction motor were to be operated at 90% rated voltage, _____________. A. there would be an increase in starting torque B. starting current would increase slightly C. synchronous speed would decrease slightly D. the slip would increase

Last Answer : Answer: D

Description : A characteristic of an induction motor with a low resistance rotor winding is _____________. A. high starting voltage B. high starting current C. high slippage D. low starting voltage

Last Answer : Answer: B

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : In a 15 HP induction-type motor with a cage rotor, the current required at standstill to produce starting torque is approximately ____________. A. half the full load current B. equal to the full load current C. five times the full load current D. ten to twenty times the full load current

Last Answer : Answer: C

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A

Description : Which motor has high Starting Torque and Staring current DC motor, Induction motor or Synchronous motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Which Motor Has High Starting Torque And Staring Current Dc Motor, Induction Motor Or Synchronous Motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Why shaded-pole single phase induction motor does not need any special starting technique like capacitors and auxiliary winding etc.

Last Answer : Because it is inherently self started motor. The construction of the poles is such that they give a sweep to the magnetic flux and motor starts rotating.

Description : Why is the starting torque of a capacitor start induction motor high?

Last Answer : Ans: The capacitor C in the starting winding is so chosen that Is leads Im by 75 degree. Since the starting torque is directly proportional to Sin Ф, and it is quite high in capacitor-start induction motor.

Description : Why is the starting torque of a resistance split-phase induction motor not high?

Last Answer : The starting torque is given as, Ts = K Im Is Sin Ф Where K = constant whose magnitude depends upon the design of the motor (i) The angle between Is and Im is small ... Im are not equal in magnitude, the rotating magnetic field is not uniform and the starting torque produced is small.

Description : How the starting winding produce rotation in a single phase resistance start induction motor?

Last Answer : The starting winding is highly resistive and the main winding is inductive. So the phase difference between the two currents becomes nearly 90 degree and hence the motor start as two phase motor.

Description : What is the function of centrifugal starting switch in a single-phase induction motor?

Last Answer : Ans: The centrifugal switch is connected in series with the starting winding. The primary function of the centrifugal switch is to produce rotating flux in conjunction with main winding at the time of ... has no function to perform and is removed from the circuit by a centrifugally operated switch.

Description : What are methods available for making single phase induction motor a self starting?

Last Answer : By slitting the single phase, by providing shading coil in the poles.