In transformer, the core is made up of soft iron in order to pass the

maximum

A. flux

B. current

C. magnetic flux

D. voltage


1 Answer

Answer :

magnetic flux


Related questions

Description : Which of the following iron core electromagnets creates the greatest amount of magnetic flux: w) 1,000 coils, 2 amps of current x) 250 coils, 7 amps of current y) 700 coils, 3 amps of current 

Last Answer : ANSWER: Y -- 700 COILS, 3 AMPS OF CURRENT

Description : 27] In a transformer, the leakage flux of each winding is proportional to the current in that winding because A. Ohm's law applies to magnetic circuits B. Leakage paths do no saturate C. the two windings are electrically isolated D. mutual flux is confined to the core

Last Answer : B. Leakage path do not saturate

Description : The best material for the core of a transformer is – (1) stainless steel (2) mild steel (3) hard steel (4) soft iron

Last Answer : (4) soft iron Explanation: Iron has a very large magnetic response: it greatly amplifies an applied magnetic field. The transformer's ability to transfer energy depends on the strength of the magnetic ... field is amplified. The input energy can then be lower while still having the same effect.

Description : The best material for the core of a transformer is (1) stainless steel (2) mild steel (3) hard steel (4) soft iron

Last Answer : soft iron

Description : A direct current passing through a wire coiled around a soft iron core is the description of a simple ____________. A. magnetic shield B. electromagnet C. piezoelectric device D. electromagnetic domain

Last Answer : Answer: B

Description : [53] The iron loss of the transformer is negligible during short circuit test because A. The entire input is just sufficient to meet Cu losses only B. Flux produced is a small fraction of the normal flux C. Iron core becomes fully saturated D. Supply frequency is held constant

Last Answer : B. Flux produced is a small fraction of the normal flux

Description : 43 The purpose of providing an iron core in a transformer is to A.Provide support to windings B. Reduce hysteresis loss C. decrease the reluctance of the magnetic path D. reduce eddy current losses

Last Answer : C. Decrease the reluctance of the magnetic path

Description : Magnitude of induced e.m.f is proportional to A. rate of change of current B. rate of change of voltage C. rate of change of magnetic flux linkage D. rate of change of resistance

Last Answer : rate of change of magnetic flux linkage

Description : Hall voltage is directly proportional to A. current B. electric field C. magnetic flux density D. all of above

Last Answer : magnetic flux density

Description : If the Earth's magnetic field lines pass through the Hall probe in opposite direction, then the change in reading of voltmeter is A. thrice the Earth's magnetic flux density B. four times the Earth ... C. five times the Earth's magnetic flux density D. twice the Earth's magnetic flux density

Last Answer : twice the Earth's magnetic flux density

Description : Ratio of voltages is inverse ratio of the A. transformer B. resistor C. iron core D. current

Last Answer : current

Description : The harmonic currents in a power transformer does not cause increase in: a) Secondary voltage b) Core loss c) Copper loss d) Magnetic interference with protective relays

Last Answer : Ans: A

Description : Total number of magnetic field lines passing through an area is called A. magnetic flux density B. magnetic flux C. e.m.f D. voltage

Last Answer : magnetic flux

Description : 12] Which is not the basic element of the transformer? A. core B. primary winding C. secondary winding D. mutual flux

Last Answer : D. Mutual flux

Description : The core flux of a practical transformer with a resistive load  A) Is strictly constant with load changes B) Increases linearly with load C) Increases as the square root of the load D) Decrease with increased load

Last Answer : The core flux of a practical transformer with a resistive load Is strictly constant with load changes

Description : The core of a transformer (medium size) uses to provide high flux densities (a) diamagnetic (c) ferromagnetic core (b) paramagnetic (d) none of these

Last Answer : The core of transformer is made up colled rolled grain oriented. It is a ferromagnetic material..

Description : What type of magnets are produce by running electric current through a soft iron core?

Last Answer : electromagnet

Description : 19 Transformer cores are built up from laminations rather than from solid metal so that A. Oil penetrates the core more easily B. Eddy current loss is reduced C. Less lamination is required for the windings D. Turn ratio is higher than voltage ratio

Last Answer : B. Eddy current loss is reduced

Description : Magnetic keepers are pieces of – (1) Nickel (2) Cobalt (3) Steel (4) Soft iron

Last Answer : (4) Soft iron Explanation: Magnetic keepers arc pieces of soft iron that are placed across the poles of a bar magnet or a horseshoe magnet. They help prevent the loss of magnetism.

Description : Magnetic keepers are pieces of (1) Nickel (2) Cobalt (3) Steel (4) Soft iron

Last Answer :  Soft iron

Description : The working of a meter is based on the use of a permanent magnet. In order to protect the meter functioning from stray magnetic fields (a) meter is surrounded by strong magnetic fields (b) a soft ... is used (c) a plastic shielding is provided (d) a shielding of anon-magnetic material is used

Last Answer : (b) a soft iron shielding is used

Description : If the magnetic flux density and current are at right angles, then component of force acting on the conductor is A. BIL cosθ B. BIL sinθ C. BIL tanθ D. BL sinθ

Last Answer : BIL sinθ

Description : For a straight wire, induced current depends uponA. the speed of movement of wire B. the length of wire C. the magnitude of magnetic flux density D. all of above

Last Answer : all of above

Description : The Weber and the Maxwell are units of measure of: w) conductance x) electrical current y) magnetic flux z) relative speed

Last Answer : ANSWER: Y -- MAGNETIC FLUX

Description : The Tesla and the Gauss are units of measure of: w) conductance x) magnetic field strength y) magnetic flux z) electrical current

Last Answer : ANSWER: X -- MAGNETIC FIELD STRENGTH

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : are used for construction of core of electromagnets. (a) Soft magnetic materials (b) Hard magnetic materials (c) Either (a) or (b) (d) None of the above

Last Answer : (a) Soft magnetic materials

Description : Find the magnetic flux density of a finite length conductor of radius 12cm and current 3A in air( in 10 -6 order) a) 4 b) 5 c) 6 d) 7

Last Answer : b) 5

Description : Transformer cores are normally made from (A) Soft ferrites (B) High purity iron (C) Grain oriented Fe-Si alloy (D) Al-Ni-Co alloy

Last Answer : (C) Grain oriented Fe-Si alloy

Description : 68 The path of a magnetic flux in a transformer should have A. High resistance B. High reluctance C. Low resistance D. Low reluctance

Last Answer : D. Low reluctance

Description : The path of the magnetic flux in a transformer has : (A) High reluctance (B) Low resistance (C) High conductivity (D) Low reluctance

Last Answer : low reluctance path

Description : The path of magnetic flux in a transformer should have?

Last Answer : The path of magnetic flux in a transformer should have low reluctance.

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : In replacing a defective transformer with a new one, which of the following actions must be carried out to insure proper operation of the equipment it serves? A. The secondary leads must be grounded ... magnetize it. D. The iron core must be grounded for 10 minutes to remove any residual magnetism.

Last Answer : Answer: B

Description : Of which irom is Core of transformer made up?

Last Answer : – Soft iron

Description : When an iron piece is placed in a magnetic field (a) the magnetic lines of force will bend away from their usual paths in order to go away from the piece (b) the magnetic lines of force will bend ... to pass through the piece (c) the magnetic field will not be affected (d) the iron piece will break

Last Answer : (b) the magnetic lines of force will bend away from their usual paths in order to pass through the piece

Description : Pick out the wrong statement. (A) A ferromagnetic material becomes paramagnetic above the 'Curie temperature' (B) Permanent magnets are made of hard materials, whereas electromagnets require soft ... hysterisis loss and coercive forces (D) Tungsten steel and alnico are not hard magnetic materials

Last Answer : Option D

Description : A component that allows only unidirectional current to pass through it is A. resistor B. inductor C. transformer D. diode

Last Answer : diode

Description : What is the core of the transformer made of ?

Last Answer : The core of the transformer is made of: The core of the transformer is usually made of a type of steel called silicon steel. Transformer cores are not usually made of normal stainless steel.

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : Figure 'B' shown in the illustration represents a/an ____________. EL-0091 A. magnetic amplifier B. Scott-T transformer C. saturable-core reactor D. oil-filled toroid

Last Answer : Answer: A

Description : Figure 'A' shown in the illustration represents a/an _______________. EL-0091 A. magnetic amplifier B. Scott-T transformer C. saturable-core reactor D. oil-filled toroid

Last Answer : Answer: C

Description : 72 Harmonics in transformer result in A. Increased core losses B. Increased I2R losses C. Magnetic interference with communication circuits D. All of the above

Last Answer : D. All of the above

Description : Strength of magnetic field of solenoid can be increased by adding core made of A. copper B. ferrous C. silver D. aluminum

Last Answer : ferrous

Description : 6 The value of flux involved in the emf equation of a transformer is A. rms value B. rms value C. Maximum value D. Instantaneous value

Last Answer : C) maximum value

Description : ______is extensively used for those portions of magnetic circuit which carry steady flux and need superior mechanical properties ? (a) Grey cast-iron (b) Cast steel (c) High carbon steel (d) Stainless steel

Last Answer : (b) Cast steel

Last Answer : The purpose of providing iron core in a step-up transformer is to decrease the magnitude of magnetizing current.

Description : When a transformer is used to step down voltage, the low voltage winding is _____________. A. part of the core B. the primary coil C. not insulated D. the secondary coil

Last Answer : Answer: D

Description : The voltage applied to the H.V. side of a transformer during S.C. test is 2% of the rated voltage. The core loss as the fraction of its rated core loss is (a) 4% (b) 0.4% (c) 0.25% (d) 0.04%

Last Answer : 0.04%

Description : In a transformer, low voltage winding is placed near the core in case of concentric windings so as to  1. Reduce the leakage flux 2. Reduce the insulation requirement 3. Reduce the risk of voltage shock in case of insulation breakdown 4. Reduce the ... a) 1, 2, 3 (b) 2, 3, 4 (c) 1, 2, 3, 4 (d) 2, 3

Last Answer : In a transformer, low voltage winding is placed near the core in case of concentric windings so as to  1. Reduce the leakage flux 2. Reduce the insulation requirement 3. Reduce the risk of voltage shock in case of insulation breakdown 4. Reduce ... ) 1, 2, 3 (b) 2, 3, 4 (c) 1, 2, 3, 4 (d) 2, 3