The voltage applied to the H.V. side of a transformer during S.C. test is 2% of the rated voltage. The core loss as the fraction of its rated core loss is (a) 4% (b) 0.4% (c) 0.25% (d) 0.04%

1 Answer

Answer :

0.04%

Related questions

Last Answer : When a given transformer is run at its rated voltage but reduced frequency, its core flux density is increased.

Description : If a transformer is switched on to a voltage more than the rated voltage?

Last Answer : If a transformer is switched on to a voltage more than the rated voltage its power factor will deteriorate.

Description : In a transformer, low voltage winding is placed near the core in case of concentric windings so as to  1. Reduce the leakage flux 2. Reduce the insulation requirement 3. Reduce the risk of voltage shock in case of insulation breakdown 4. Reduce the ... a) 1, 2, 3 (b) 2, 3, 4 (c) 1, 2, 3, 4 (d) 2, 3

Last Answer : In a transformer, low voltage winding is placed near the core in case of concentric windings so as to  1. Reduce the leakage flux 2. Reduce the insulation requirement 3. Reduce the risk of voltage shock in case of insulation breakdown 4. Reduce ... ) 1, 2, 3 (b) 2, 3, 4 (c) 1, 2, 3, 4 (d) 2, 3

Last Answer : The no load current in a transformer lags behind the applied voltage by an angle of about 75°.

Description : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

Last Answer : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : if the rated voltage from the power lines is applied to the primary of a single-phase transformer which is operated on no-load, then

Last Answer : if the rated voltage from the power lines is applied to the primary of a single-phase transformer which is operated on no-load, then input voltage is sinusoidal and input current is non sinusoidal.

Description : Rated power of a bulb at V voltage is P. Now, same voltage V is applied in all conditions mentioned in Column I. Match this Column I with Column II in

Last Answer : Rated power of a bulb at V voltage is P. Now, same voltage V is applied in all conditions ... Column II in which actual total power consumed is given.

Description : A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both LV and HV windings, ... .0% of the rated current (C) 80.0% of the rated current (D) 88.8% of the rated current

Last Answer : A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both ... measured loss is 81 W. The transformer has maximum efficiency when operated at 80.0% of the rated current

Description : State any four characteristics of core type transformer.

Last Answer : Characteristics of core type transformer: i) It has one window. ii) It has one magnetic circuit. iii) Core surrounds the winding. iv) Average length of core is more. v) Area of cross ... Better cooling for winding. vii) Mechnical strength is comparatively less. viii) Repair and maintenance is easy.

Description : The core flux of a practical transformer with a resistive load  A) Is strictly constant with load changes B) Increases linearly with load C) Increases as the square root of the load D) Decrease with increased load

Last Answer : The core flux of a practical transformer with a resistive load Is strictly constant with load changes

Description : For a pulse transformer, the material used for its core and the possible turn ration from primary to secondary are respectively   (A) ferrite : 20 : 1 (B) laminated iron : 1 :1 (C) ferrite : 1 : 1 (D) powered iron : 1: 1

Last Answer : For a pulse transformer, the material used for its core and the possible turn ration from primary to secondary are respectively ferrite : 1 : 1

Description : A transformer core is laminated to?

Last Answer : A transformer core is laminated to reduce eddy current losses.

Last Answer : The purpose of providing an iron core in a transformer is to decrease the reluctance of the magnetic path.

Last Answer : The purpose of providing iron core in a step-up transformer is to decrease the magnitude of magnetizing current.

Last Answer : Material used for construction of transformer core is usually silicon steel.

Last Answer : The core used in high frequency transformer is usually air core .

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : The size of a transformer core will depend on?

Last Answer : The size of a transformer core will depend on frequency and area of the core.

Description : Reduction in core losses and increase in permeability are obtained with transformer employing?

Last Answer : Reduction in core losses and increase in permeability are obtained with transformer employing core built-up of laminations of cold rolled grain oriented steel.

Description : Why the open circuit test on a transformer is conducted at rated voltage?

Last Answer : A:The open circuit on a transformer is conducted at a rated voltage because core loss depends upon the voltage. This open circuit test gives only core loss or iron loss of the transformer.

Description : [53] The iron loss of the transformer is negligible during short circuit test because A. The entire input is just sufficient to meet Cu losses only B. Flux produced is a small fraction of the normal flux C. Iron core becomes fully saturated D. Supply frequency is held constant

Last Answer : B. Flux produced is a small fraction of the normal flux

Description : For V/F control, when frequency is increased in transformer a) Core loss component current increases, Magnetizing component current decreases b) Core loss component current increases, ... component current decreases d) Core loss component current decreases, Magnetizing component current increases

Last Answer : Ans: Core loss component current decreases, Magnetizing component current decreases

Description : Turn ratio of a transformer is 5. If 220 V AC is applied to its primary coil, voltage in the secondary coil will be: a. 44V b. 4.4 V c. 220V d. 1100V

Last Answer : c. 220V

Description : An AC supply of 230 V is applied to half wave rectifier circuit. A transformer turns ratio is 20 : 1. Find i) Output DC voltage (ii) Peak Inverse Voltage (PIV)

Last Answer : Solution:

Description : The harmonic currents in a power transformer does not cause increase in: a) Secondary voltage b) Core loss c) Copper loss d) Magnetic interference with protective relays

Last Answer : Ans: A

Description : 19 Transformer cores are built up from laminations rather than from solid metal so that A. Oil penetrates the core more easily B. Eddy current loss is reduced C. Less lamination is required for the windings D. Turn ratio is higher than voltage ratio

Last Answer : B. Eddy current loss is reduced

Description : During open circuit test of a transformer?

Last Answer : During open circuit test of a transformer primary is supplied rated voltage.

Description : Why the earthing transformer primary voltage is 16.5 kV rated in main generator even though actual voltage during the E/F is root 3 times less?

Last Answer : The transformer should not saturate during E/F otherwise it will cause ferroresonance with the GT winding capacitance. Dangerous O/V and neutral shifting will occur. During loss of load or field ... saturation. Saturation can also occur due to point on wave of application causing flux doubling. 

Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be (A) 3.6 V. (B) 2.5 V. (C) 3.0 V. (D) 6.0 V.

Last Answer : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be 3.0 V.

Description : A single-phase, 50 kVA, 250 V/500 V two winding transformer has an efficiency of 95% at full load, unity power factor. If it is re-configured as a 500 V/750 V auto-transformer, its efficiency at its new rated load at unity power factor will be  (A) 95.752% (B) 97.851% (C) 98.276% (D) 99.241%

Last Answer : A

Description : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are   (a) 32, 36 (b) 20, 36 (c) 25, 50 (d) 40, 80 

Last Answer : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are 20, 36

Description : For given applied voltage, with the increase in frequency of the applied voltage?

Last Answer : For given applied voltage, with the increase in frequency of the applied voltage eddy current loss will remain unchanged.

Description : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are (A) 140 W (B) 180 W (C) 240 W (D) 480 W

Last Answer : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are 240 W

Description : State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation

Last Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Description :  If the frequency of input voltage of a transformer is increased keeping the magnitude of voltage unchanged, then: A) both hysteresis loss and eddy current loss in the core will increase B) ... current loss will increase D) hysteresis loss will decrease but eddy current loss will remain unchanged

Last Answer :  If the frequency of input voltage of a transformer is increased keeping the magnitude of voltage unchanged, then: hysteresis loss will decrease but eddy current loss will remain unchanged

Description : In a transformer the voltage regulation will be zero when it operates at (A) unity p.f. (B) leading p.f. (C) lagging p.f. D) zero p.f. leading.

Last Answer : In a transformer the voltage regulation will be zero when it operates at leading p.f.

Description : If the secondary turns of a transformer are doubled and at the same time primary voltage is reduced to half then the secondary voltage will

Last Answer : If the secondary turns of a transformer are doubled and at the same time primary voltage is reduced to half then the secondary voltage will not change

Description : In a transformer, zero voltage regulation at full load is   (a)Not possible   (b) Possible at unity power factor load   (c) Possible at leading power factor load   (d) Possible at lagging power factor load

Last Answer : In a transformer, zero voltage regulation at full load is Possible at leading power factor load 

Last Answer : A transformer cannot raise or lower the voltage of a D.C. supply because Faraday's laws of electromagnetic induction are not valid since the rate of change of flux is zero.

Description : A good voltage regulation of a transformer means?

Last Answer : A good voltage regulation of a transformer means output voltage fluctuation from no load to full load is least.

Description : The voltage transformation ratio of a transformer is equal to the ratio of?

Last Answer : The voltage transformation ratio of a transformer is equal to the ratio of secondary induced e.m.f. to primary induced e.m.f.

Description : 49 The open circuit test is carried out in a transformer to find the A. Cu loss B. Core loss C. Total loss D. Insulation resistance

Last Answer : B. Core loss

Description : Full load copper loss in a transformer is 1600 watts. At half load the copper loss will be: A) 6400 watt B) 1600 watt C) 800 watt D) 400 watt

Last Answer :  Full load cupper loss in a transformer is 1600 watts. At half load the cupper loss will be: 400 watt

Last Answer : The full-load copper loss of a trans¬former is 1600 W. At half-load, the copper loss will be 400 W.

Description : In an actual transformer the iron loss remains practically constant from no load to full load because?

Last Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

Last Answer : If the supply frequency to the transformer is increased, the iron loss will increase.

Last Answer : Iron loss of a transformer can be measured by low power factor wattmeter.

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D