Description : Motor controllers are seldom troubled by grounds because ________________. A. cabinet heaters always keep internal components dry B. special insulation is used on wire for vital circuits C. ... on controller panels greatly reduce vibration D. contactors and relays are mounted on nonconducting panels
Last Answer : Answer: D
Description : The insulation of electric generators during short idle periods should be _____________. A. allowed to cool slowly to ambient temperatures B. flashed with direct current to remove any residual ... using strip or space heaters D. relieved of all capacitive charge by grounding the conductors
Last Answer : Answer: C
Description : Which of the following procedures should be used to maintain a large electric motor during periods of inactivity? A. A thin layer of air-drying varnish should be applied on the windings. B. ... periodically to remove carbon dust. D. Space heaters should be used to prevent condensation of moisture.
Description : On large generators, space heaters are used to ____________. A. keep the machine at ambient tmperature of the machinery space B. maintain rotor and stator winding temperatures above the dew point ... C. prevent condensation in the lube oil D. prevent electrolysis due to condensation in the bearings
Last Answer : Answer: B
Description : Which of the listed devices may be installed on a large diesel-electric alternating current propulsion generator? A. Temperature detector coils inserted in the stator slots for measuring stator temperature. B. ... . C. Electric space heaters to prevent condensation of moisture. D. All of the above.
Description : Which of the listed devices may be installed on a large turbo-electric alternating current propulsion generator? A. Temperature detector coils inserted in the stator slots for measuring stator temperature. B. A ... . C. Electric space heaters to prevent condensation of moisture. D. All of the above.
Description : Moisture damage, as a result of condensation occurring inside of the cargo winch master switches, can be reduced by __________________. A. installing a light bulb in the pedestal stand B. coating the ... epoxy sealer C. venting the switch box regularly D. using strip heaters inside the switch box
Description : One function of the movable cams in a drum-type motor controller is to _____________. A. regulate the speed of the motor B. maintain resistance contacts in clean condition C. insulate the operating handle D. limit the amount of load put on the motor
Last Answer : Answer: A
Description : Transformers are used onboard ships with AC generators to _____________. A. change frequency B. increase power output to modulating frequency controllers C. decrease power output to modulating frequency ... D. permit higher voltage for electric motor operation and low voltage for lighting circuits
Description : Motor controllers are seldom troubled with grounds because _____________. A. the auxiliary contacts have a high resistance connection B. the contactors and relays are mounted on a nonconducting panel ... individual series-connected units D. there are separate switches for the motor and the control
Description : The rated temperature rise of an electric motor is the _____________. A. average temperature at any given latitude B. normal temperature rise above the standard ambient temperature at rated load ... D. permissible difference in the ambient temperature of the motor due to existing weather conditions
Description : In addition to short circuits and sustained overloads, fuses are likely to blow due to _____________. A. loose fuse clips B. low ambient temperatures C. low contact resistance D. all of the above
Description : Magnetic controller contacts may become welded together during operating conditions as a result of _____________. A. high spring pressure B. high ambient temperature C. an open coil D. low voltage on operating coil
Description : Magnetic controller contacts may become welded together during operation because of _____________. A. excessive magnetic gap B. low contact pressure C. an open coil D. excessive ambient temperature
Description : When troubleshooting a magnetic controller, it is found that the contacts are welded together. The most probable cause is _____________. A. excessive operation at low load B. high ambient temperature C. low voltage on the operating coil D. high voltage on the operating coil
Description : Magnetic controller contacts may become welded together during operation due to _____________. A. an open coil B. low contact pressure C. excessive ambient temperature D. excessive magnetic gap
Description : Which of the following statements describes the significance of ambient temperature in relation to the service life of electronic components? A. Ambient temperature should be as high as possible to drive ... is kept low. D. A reduced ambient temperature causes a corresponding reduced service life.
Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. keep the lube oil warm for quick starting B. prevent moisture from condensing in the ... is shutdown C. prevent the windings from becoming brittle D. prevent acidic pitting of the slip rings
Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. prevent the windings from becoming brittle B. prevent moisture from condensing in the windings during ... C. prevent acidic pitting of the slip rings D. keep the lube oil warm for quick starting
Description : The devices marked 'T' in the illustration are _____________. EL-0080 A. trouble alarm units whose contacts activate when problems arise either on starting or stopping of the motor B. topping ... contactor parts whose contacts start and stop the defrosting cycle of the compressor driven by the motor
Description : Which of the following precautions should you take when securing propulsion generators and motors for an extended period of time? A. Disconnect the brush pigtails from their contacts and circulate air ... Lift the brushes from commutator collector rings and circulate cool dry air through the units.
Description : Moisture accumulating in electric motors and generator windings having a cold insulation resistance greater than 50,000 ohms may be baked out with internal heat. This heat can be developed by ____________. ... an electric welder and feeding it into the armature while running the motor at full speed
Description : Time delayed or delayed action-type fuses are designed to _____________. A. prevent grounds in branch circuits B. prevent opens in motor circuits C. permit momentary overloads without melting D. guard lighting and electronic circuits
Description : If a DC motor runs hot, the cause may be _____________. A. high mica condition B. low ambient temperature C. clogged ventilation ducts D. an open in the shunt field
Description : One item listed on the name plate of a cargo pump motor is 'degrees centigrade rise.' This number is based on _____________. A. normal temperature change from cold to hot B. an ambient temperature ... . minimum heat rise from no load to full load D. maximum degrees centigrade rise from absolute zero
Description : Ambient temperature is the _____________. A. amount of temperature rise with no load B. amount of temperature developed by an operating motor C. temperature of the compartment where the motor is located D. normal operating temperature, less the room temperature
Description : Ambient temperature is the _____________. A. amount of temperature rise with no load B. temperature of the compartment where the motor is located C. normal operating temperature, less the room temperature D. amount of temperature developed by an operating motor
Description : Motor name plate data includes '°°C rise'. This indicates the _____________. A. actual running temperature of the winding from no load to full load B. permissible temperature rise ... above normal full load operating temperature D. maximum allowable temperature rise for continuous no load service
Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection
Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load
Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding
Description : A low-voltage protection circuit is used in electric motor starting equipment to _____________. A. trip circuit contactors when the motor overspeeds due to low voltage B. trip circuit ... voltage without manually resetting D. prevent the motor from restarting automatically on restoration of voltage
Description : A shading coil used in an AC magnetic controller, functions to _____________. A. reduce vibration and noise in the contactor B. prevent flux buildup in the operating coil C. eliminate arcing when the contacts close D. energize the operating coil and 'pull in' the contacts
Description : Unless it can be shown that a 45°C ambient temperature will not be exceeded, motors within a machinery space must be designed for an ambient temperature of _____________. A. 45°C B. 50°C C. 55°C D. 60°C
Description : If a small electric motor has been submerged in saltwater for a short period of time, you should _____________. A. send it ashore for rewinding B. rinse it with warm freshwater and bake it dry ... and bake with internal heat D. clean it with carbon tetrachloride and blow it out with compressed air
Description : An adjustable resistor, whose resistance can be changed without opening the circuit in which it is connected, is called a _____________. A. bleeder resistor B. rheostat C. bridge D. variable shunt strip
Description : Do outdoor electric heaters really help in freezing weather?
Last Answer : Outdoor electric heaters are a Godsend to those who have to be outside in freezing weather. They provide a respite from the cold and depending on the size of the heater and fans that distribute the heat can provide a large area of heat.
Description : Motor starter or controller contacts may become welded together if the contacts _____________. A. open too quickly and arc B. close under excessive pressure C. open or close too quickly D. close under excessive starting current
Description : The pitting of controller contacts can be caused by _____________. A. excessive spring pressure B. insufficient contact pressure C. continuous motor overload D. all of the above
Description : Motor controller or starter contacts may become pitted and welded together if the contacts _____________. A. open under loaded conditions B. close slowly with light pressure C. open too quickly and arc D. close quickly with proportionate pressure
Description : The main difference between a motor control circuit containing low voltage protection and low voltage release is that the latter contains _____________. A. a magnetic operating coil B. normally open line contacts C. thermal-overload protection D. a momentary-contact start button
Description : Due to the operating characteristics of the system, time lag fuses (or dual-element fuses) are necessary for use in _____________. A. main lighting circuits B. motor starting circuit C. emergency lighting circuits D. general alarm circuits
Description : RC time constant characteristics, as shown in the illustration, are important in _____________. EL-0086 A. bridge rectifiers for alternator excitation B. timing and pulse shaping circuits C. transistor power amplifier biasing D. motor controller overload protection
Description : Some large A.C. motors are equipped with with heaters. These could be ___________. I. resistance heaters bolted directly to the frame II. low voltage windings embedded in the motor windings A. I only B. II only C. either I or II D. neither I or II
Description : If the motor shown in the illustration will not start when 'Q' is depressed, which of the listed components should be checked FIRST? EL-0017 A. Fuses 'F-1' and 'F-2'. B. Operating coil 'C'. C. Contacts 'H-1', 'H-2', and 'H-3'. D. Contact 'H-4'.
Description : Components that provide internal storage to the CPU are ______ a) Registers b) Program Counters c) Controllers d) Internal chips
Last Answer : Answer: a Explanation: The Registers are the fast storage units. They are responsible for storing intermediate computational results in the CPU. The registers can be user accessible or inaccessible
Description : When shipboard electrical distribution circuits are connected in parallel, additional parallel circuits will cause the total circuit resistance to _____________. A. increase, causing a drop in the line current B ... an increase in the line voltage D. decrease, causing an increase in the line current
Description : AC circuits develop resistance, inductance, and capacitance. The inductive reactance of a circuit is expressed in _____________. A. ohms B. mhos C. henrys D. farads
Description : Alternating current circuits develop resistance, inductance, and capacitance. The capacitance of individual capacitors is expressed in _____________. A. ohms B. mhos C. henrys D. farads
Description : Alternating current circuits develop resistance, inductance and capacitance. The inductance of a coil is expressed in _____________. A. ohms B. mhos C. henrys D. farads