Which of the listed devices may be installed on a large diesel-electric alternating current propulsion generator? A. Temperature detector coils inserted in the stator slots for measuring stator temperature. B. A CO2 fire extinguishing system. C. Electric space heaters to prevent condensation of moisture. D. All of the above.

1 Answer

Answer :

Answer: D

Related questions

Description : Which of the listed devices may be installed on a large turbo-electric alternating current propulsion generator? A. Temperature detector coils inserted in the stator slots for measuring stator temperature. B. A ... . C. Electric space heaters to prevent condensation of moisture. D. All of the above.

Last Answer : Answer: D

Description : Which of the following procedures should be used to maintain a large electric motor during periods of inactivity? A. A thin layer of air-drying varnish should be applied on the windings. B. ... periodically to remove carbon dust. D. Space heaters should be used to prevent condensation of moisture.

Last Answer : Answer: D

Description : On large generators, space heaters are used to ____________. A. keep the machine at ambient tmperature of the machinery space B. maintain rotor and stator winding temperatures above the dew point ... C. prevent condensation in the lube oil D. prevent electrolysis due to condensation in the bearings

Last Answer : Answer: B

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. keep the lube oil warm for quick starting B. prevent moisture from condensing in the ... is shutdown C. prevent the windings from becoming brittle D. prevent acidic pitting of the slip rings

Last Answer : Answer: B

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. prevent the windings from becoming brittle B. prevent moisture from condensing in the windings during ... C. prevent acidic pitting of the slip rings D. keep the lube oil warm for quick starting

Last Answer : Answer: B

Description : Electric strip heaters are used in motor controllers to _____________. A. prevent freezing of movable contacts B. keep the components at their design ambient temperature C. prevent condensation of moisture D. minimize resistance in internal circuits

Last Answer : Answer: C

Description : Which of the listed procedures should be carried out to prevent moisture damage to electrical apparatus during extended periods of idleness? A. Fill the motor housing with CO2 to inert the space. B. Strap ... C. Place heat lamps in the motor housings. D. Cover the equipment with a canvas tarpaulin.

Last Answer : Answer: C

Description : In a diesel electric plant, raising the generator's field excitation will cause the DC propulsion motor to ________. A. increase in speed B. decrease in speed C. affect generator speed only D. affect main motor speed if done in conjunction with higher generator engine speeds

Last Answer : Answer: A

Description : On some diesel-electric ships, the DC propulsion motor will only attain half speed when the generator fields are fully excited. Speeds above this are obtained by _____________. A. rotating brush ... B. raising the generator engine speed C. lowering the generator engine speed D. decreasing excitation

Last Answer : Answer: B

Description : Expansion cards are inserted into: a) The back of the computer b) Slots c) CPU d) Internally Installed e) None of These

Last Answer : b) Slots

Description : Moisture damage, as a result of condensation occurring inside of the cargo winch master switches, can be reduced by __________________. A. installing a light bulb in the pedestal stand B. coating the ... epoxy sealer C. venting the switch box regularly D. using strip heaters inside the switch box

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require that the emergency diesel generator engine shut down when _____________. A. lubricating oil pressure is lost B. the engine overspeeds dangerously C. fixed CO2 is released into the emergency diesel generator space D. all of the above

Last Answer : Answer: D

Description : Which of the methods listed is used to start a AC generator turning? A. Residual magnetism remaining in the field poles. B. Residual magnetism remaining in the field coils. C. Residual magnetism remaining in the armature. D. Rotation by a mechanical prime mover.

Last Answer : Answer: D

Description : In the illustrated schematic diagram, which of the listed devices prevents the forward and reversing coils from being energized simultaneously? EL-0011 A. An 'either-or' interlock B. A mechanical interlock C. Blowout coils D. A stop button

Last Answer : Answer: A

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : In a compound-wound motor, a portion of the line current flows through the _____________. A. inertial poles B. stator C. shunt field coils D. frame

Last Answer : Answer: C

Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : List the undesirable effects produced by certain combination of rotor and stator slots.

Last Answer : 1. The motor may refuse to start (cogging) 2. The motor may run at sub synchronous speed (Crawling) 3. Severe vibrations may develop and the noise will be excessive.

Description : The direction of propeller shaft rotation in a turbo-electric synchronous propulsion drive motor is changed by reversing the _____________. A. polarity of the propulsion motor B. polarity of the propulsion generator C. phase sequence of power to the motor D. phase sequence of power to the generator

Last Answer : Answer: C

Description : The propeller shaft speed in a turbo-electric, synchronous, propulsion drive motor is changed by varying the __________. A. turbine speed B. number of motor poles C. field strength of the generator D. field strength of the motor

Last Answer : Answer: A

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : On a vessel with turbo-electric drive, which of the following conditions would indicate that the propulsion motor had dropped out of synchronization with the propulsion generator? A. Excessive ... Tripped main motor interlocks C. Overheated crosstie busses D. Closed contact in the field circuits

Last Answer : Answer: A

Description : In D.C. motor construction, the armature coils' ends are _______________. A. soldered to the commutator bar risers B. imbedded into core slots C. crimped together with brush pigtails D. spliced with the field windings

Last Answer : Answer: A

Description : Electric propulsion coupling excitation is reduced at slow speeds to ___________. A. increase speed control B. increase shaft torque C. prevent coupling overheating D. prevent coupling slippage

Last Answer : Answer: C

Description : The insulation of electric generators during short idle periods should be _____________. A. allowed to cool slowly to ambient temperatures B. flashed with direct current to remove any residual ... using strip or space heaters D. relieved of all capacitive charge by grounding the conductors

Last Answer : Answer: C

Description : Amortisseur windings are installed in a synchronous motor to _____________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : A four pole turbogenerator is used in conjunction with a 160 pole propulsion motor. If the generator is turning at 3,200 RPM, what is the current speed of the propeller? A. 40 RPM B. 60 RPM C. 80 RPM D. 100 RPM

Last Answer : Answer: C

Description : A three-phase, squirrel cage, induction motor will run hot due to _____________. A. open stator coils B. high power factor C. dirty or corroded slip rings D. reversed commutating poles

Last Answer : Answer: A

Description : When troubleshooting AC motors, a portable growler can be used for locating ____________. A. open field coils B. grounded field coils C. grounded stator coils D. shorted stator coils

Last Answer : Answer: D

Description : An overload in which of the listed motors will result in the illumination of an indicating light at the propulsion control station alarm panel? A. Fuel pump motor B. Steering motor C. Condensate pump motor D. Forced draft blower motor

Last Answer : Answer: B

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : How does propulsion of diesel and electric (trolley) buses differ?

Last Answer : Less weight. And, electric motor has more torque.

Description : Voltage failure of an AC generator may be caused by ____________. A. failure of the exciter generator B. a tripped bus circuit breaker C. high mica segments on the stator bus bar D. excessive prime mover speed

Last Answer : Answer: A

Description : A three-phase, induction-type motor experiences an open in one phase. Which of the listed automatic protective devices will prevent the machine from being damaged? A. Overspeed trip B. Thermal overload relay C. Three-pole safety switch D. Magnetic blowout coil

Last Answer : Answer: B

Description : A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an _____________. A. rotor B. stator C. exciter D. armature

Last Answer : Answer: C

Description : What type of devices may not have Google play installed? A. Amazon Fire tablets B. Very low cost devices C. Devices sold in China D. All of the above

Last Answer : D. All of the above

Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip

Last Answer : Answer: D

Description : Which of the following components are used to convert alternating current produced in the generator windings to direct current? A. Armature and equalizer B. Commutator and brushes C. Rotor and interpoles D. Field and exciter

Last Answer : Answer: B

Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes

Last Answer : Answer: B

Description : Presence of moisture in fuel oil would (A) Keep the burner tips cool (B) Aid in proper combustion (C) Because sputtering, possibly extinguishing flame (D) Clean the nozzles

Last Answer : (D) Clean the nozzles

Description : The prime mover of an AC two pole main propulsion generator drives the generator at 3600 RPM. If the main propulsion motor has 80 poles, what will be the propeller speed? A. 45 RPM B. 80 RPM C. 90 RPM D. 180 RPM

Last Answer : Answer: C

Description : You have installed a Zener diode in parallel with a load. While measuring the voltage across the Zener diode it is found that it does not change as the current through the load increases. This means that the ... is working as it should B. is shorted C. is open D. does not regulate as it should

Last Answer : Answer: A