What controls rudder movement when the Operation Selector Switch shown in the illustration is in the 'NFU' position? EL-0097 A. Steering wheel B. Non-followup controller C. Gyro-compass D. Course selector pointer

1 Answer

Answer :

Answer: B

Related questions

Description : What controls the rudder when the 'operation selector switch' of the steering stand shown in the illustration is in the 'HAND' position? EL-OO98 A. Non-followup controller B. Gyro-compass C. Course selector pointer D. Steering wheel

Last Answer : Answer: D

Description : As shown in the illustrations, feedback or rudder angle repeatback is used by the steering stand in which operational modes? EL-0097 A. Gyro-compass and hand steering only B. Hand steering and non-followup only C. Non-followup and gyro-compass only D. Gyro-compass and synchronizing only

Last Answer : Answer: A

Description : If the steering stand selector switch is allowed to remain in the 'Non-Followup' mode after testing of the steering gear, the rudder will _____________. EL-0097 A. not respond to commands from the ... actuator D. stop moving only when the helm is counter-rotated to put the pump at neutral stroke

Last Answer : Answer: A

Description : As shown in the illustrations, fine adjustments such as 'weather' and 'turning rate' have no effect on steering stand operation when the 'operation control switch' is in ____________. EL-0097 A. GYRO B. HAND C. NFU D. DIFF

Last Answer : Answer: C

Description : As shown in the illustrations, ordered rudder angle is fed back from the ________________. EL-0097 A. power unit to the magnetic amplifier B. steering gear to the control potentiometer C. magnetic amplifier to the steering gear D. rudder yoke to the non-followup controller

Last Answer : Answer: A

Description : The only point in the steering stand shown in the illustration which needs periodic lubrication is the ______________. EL-0098 A. repeater assembly ball bearings B. steering wheel bearing C. operation selector switch D. course selector pointer

Last Answer : Answer: B

Description : How many modes of rudder positioning are available using the steering stand shown in the illustrations? EL-0097 A. One B. Two C. Three D. Four

Last Answer : Answer: C

Description : Which of the devices shown in the illustration automatically prevents the simultaneous operation of the windlass from both master switches? EL-0073 A. Selector switch B. Contact 'CR1a' C. Contact 'CR2a' D. Contact 'CR1D'

Last Answer : Answer: D

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'TEST' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: B

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'OFF' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: A

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'ON' position, contacts '3,4' and '7,8' are respectively ______________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: D

Description : Component 'D' in section 'I' shown in the illustration represents a ____________. EL-0093 A. selector switch B. vibrating reed indicator C. junction box D. ring counter

Last Answer : Answer: A

Description : The 'reset' contacts of the master switch shown in the illustration provides the winch controller with ___________. EL-0102 A. low voltage release B. overload protection C. low voltage protection D. high power factor correction

Last Answer : Answer: C

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : The 'safe switch' of the winch controller shown in the illustration is operated _______________. EL-0102 A. through the master switch handle B. when heater circuit current is high C. by contactor coil 'FR' D. manually by the winch operator

Last Answer : Answer: D

Description : The diagrams shown in the illustration represent a/an _______________. EL-0093 A. engine order telegraph circuit B. rudder angle indicator arrangement C. engine speed tachometer with repeaters D. sound powered telephone system

Last Answer : Answer: D

Description : As shown in the illustration, which of the listed actions of the synchroscope pointer is occurring? EL-0002 A. Revolving slowly in the slow direction. B. Revolving rapidly in the slow direction. C. ... stationary at the 12 o'clock position since the leading edges of the A phases are in phase.

Last Answer : Answer: C

Description : Which of the following statements is true concerning the motor controller diagram shown in the illustration? EL-0023 A. Terminal 'T2' is hot only on high speed. B. Both indicating lights will be lit on ... high speed operation only. D. 'L2' is always connected to 'T2' whenever the motor is running.

Last Answer : Answer: D

Description : The 'pitch controller module' shown in the illustration is fed the actual pitch position of the propeller from the _____________. EL-0095 A. 'pitch meter' B. 'pitch feedback potentiometer' C. #5 relay position D. pitch error signal

Last Answer : Answer: B

Description : In accordance with Coast Guard Regulations (46 CFR), a steering gear feeder circuit from the emergency switchboard or alternate power supply must have the capacity for continuous operation of the rudder 15° side to side in not more than 60 seconds for a A. 1/4 hour B. 1/2 hour C. 1 hour D. 2 hours

Last Answer : Answer: B

Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'

Last Answer : Answer: C

Description : When the operating handle is in the 'off' position, which master switch contacts for the winch shown in the illustration are closed? EL-0102 A. 'MS-DB & OL' B. 'MS-3, 5, 6, 7, & 8' C. 'MS-LVa & OL' D. 'MS-3, 7 & Reset'

Last Answer : Answer: D

Description : The purpose of a 'slew rate controller' in a circuit such as shown in the illustration is to ______________. EL-0096 A. limit the rate of change of a signal B. introduce a 'live zero' ... linear input into a non-linear output D. reduce air pressure to a value required by a combination circuit

Last Answer : Answer: A

Description : Peripheral components for the operation of the astern valve position amplifier circuit shown in the illustration are _____________. EL-0099 A. resistors B. operated on +28 volts D.C. C. located on a separate circuit card D. all of the above

Last Answer : Answer: C

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : In order to prevent the winch shown in the illustration from turning while troubleshooting the controller circuit, _________________. EL-0102 A. set the dynamic brake by clamping contact 'DB' closed B. set the ... at 'B1' and 'B2' D. open the test link preventing current flow to the armature

Last Answer : Answer: D

Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'

Last Answer : Answer: C

Description : The +5 volt regulated power supply shown in the illustration is fed directly from the _______________. EL-0094 A. 115 volt AC bus B. Annunciator Module C. +24 volt supply D. Annunciator Controller

Last Answer : Answer: C

Description : As shown in the illustration, the circuit which 'shapes' the linear output of the thrust lever so that the steady-state ship speed is linear with respect to that lever's setting is the _____________. EL-0095 A. 'pitch controller' B. 'error amplifier' C. 'function generator' D. 'servo amplifier'

Last Answer : Answer: C

Description : What is the purpose of the 'annunciator module' (6000F35) shown in the illustration? EL-0094 A. Provide an input to the setpoint module. B. Drive the alarm lamp and, through the controller, the horn. ... and +24 volts to their respective power supplies. D. Connect 24 volts to both sides of the horn.

Last Answer : Answer: B

Description : RC time constant characteristics, as shown in the illustration, are important in _____________. EL-0086 A. bridge rectifiers for alternator excitation B. timing and pulse shaping circuits C. transistor power amplifier biasing D. motor controller overload protection

Last Answer : Answer: B

Description : If the line voltage to the controller shown in the illustration is 440 volts, what is applied across the control circuit? EL-0080 A. 110 volts B. 220 volts C. 440 volts D. 660 volts

Last Answer : Answer: C

Description : The diagram shown in the illustration represents a _________. EL-0058 A. dual speed, 2-winding motor controller B. navigation running light circuit C. single phase, 2-motor selectable starter D. common fluorescent lighting circuit

Last Answer : Answer: B

Description : What operational characteristics do the components labeled as 'S' and 'R' represent in the motor controller diagram shown in the illustration? EL-0080 A. Standard and Reverse directions B. Stop and Restart features C. Subnormal and Regular loading D. Start and Run functions

Last Answer : Answer: D

Description : If the line voltage to the controller shown in the illustration is 440 volts, what voltage is applied across the motor when contacts 'S' close? EL-0080 A. 110 volts B. 220 volts C. 440 volts D. 660 volts

Last Answer : Answer: B

Description : The voltage at the reference electrode of the circuit shown in the illustration is applied to the input of a/an ______________. EL-0090 A. class A detector whose output drives an ... drives an 2-stage isolation transformer D. magnetic amplifier whose output controls a saturable reactor

Last Answer : Answer: D

Description : [img] https:///wp-content/uploads/2016/01/teszt16.jpg [/ img] The "A" vehicle The "B" vehicle Your steering wheel car

Last Answer : 1.Vehicle marked "A"

Description : As shown in the illustration, the symbol is used in electrical drawings to designate a ____________. EL-0026 A. limit switch with one set of normally open contacts B. maintaining type ... type push button with a mechanical interlock D. normally closed contact held open mechanically by an interlock

Last Answer : Answer: C

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : As shown in the illustration, the function of the switch labeled 'PFSW' is to determine the ______________. EL-0003 A. bus frequency B. reactive volt amperes of the bus C. frequency of either generator D. power factor of either generator

Last Answer : Answer: D

Description : As shown in the illustration, 'B' is a ____________. EL-0058 A. single-pole, double-throw switch B. double-pole, single-throw switch C. double-pole, double-throw switch D. circuit breaker

Last Answer : Answer: C

Description : When reading AC current with the multimeter shown in the illustration and you are unsure of the range, the range switch should be set to ___________. EL-0047 A. 10 MA/ 10 AMP with leads in the (-10 A ... leads in the (-COMMON) and (+10 A) jacks D. unable to measure AC current with this multimeter

Last Answer : Answer: D

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : Which of the listed conditions occur when '4th point lower' is selected on the winch shown in the illustration? EL-0102 A. Master switch contacts '3', '4', '6', '8', '9', & '10' close. B. Contactors '2, 3, & 4M' and ' ... , '7', '8', and '9' close. D. Contactors '1 & 3M' and '1, 2, & 3A' pick up.

Last Answer : Answer: B