Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'TEST' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed
Last Answer : Answer: B
Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'ON' position, contacts '3,4' and '7,8' are respectively ______________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed
Last Answer : Answer: D
Description : In the system shown in the illustration, the station at section I is unable to signal any other station nor is any other station able to signal the station in section I. The station can, however, ring ... only a single station to respond to itself. D. The switch at component 'C' is stuck open.
Description : When the operating handle is in the 'off' position, which master switch contacts for the winch shown in the illustration are closed? EL-0102 A. 'MS-DB & OL' B. 'MS-3, 5, 6, 7, & 8' C. 'MS-LVa & OL' D. 'MS-3, 7 & Reset'
Description : As shown in the illustration, the symbol is used in electrical drawings to designate a ____________. EL-0026 A. limit switch with one set of normally open contacts B. maintaining type ... type push button with a mechanical interlock D. normally closed contact held open mechanically by an interlock
Last Answer : Answer: C
Description : 'A-1', as shown in the illustration, is/are ____________. EL-0017 A. normally-closed overload relay contacts B. a double pole knife switch C. normally-open overload relay contacts D. a single pole knife switch
Last Answer : Answer: A
Description : The contacts operated by the D.C. relay coil shown in the illustration are located in the schematic diagram prints at coordinates ____________. EL-0100 A. '41Y' on this page B. '52M52M' and '52H35M' C. '57R' on this page D. '52N' on page '57R'
Description : Component 'D' in section 'I' shown in the illustration represents a ____________. EL-0093 A. selector switch B. vibrating reed indicator C. junction box D. ring counter
Description : For console circuit card 'LLEA' as shown in the illustration at coordinates '63R/S', the input(s) and output(s) are respectively on pin numbers ____________. EL-0100 A. '5' and '3' & '4' B. '2' & '3' and '5' & '6' C. '5' & '6' and '2' & '3' D. '3' & '4' and '5'
Description : What controls rudder movement when the Operation Selector Switch shown in the illustration is in the 'NFU' position? EL-0097 A. Steering wheel B. Non-followup controller C. Gyro-compass D. Course selector pointer
Description : What controls the rudder when the 'operation selector switch' of the steering stand shown in the illustration is in the 'HAND' position? EL-OO98 A. Non-followup controller B. Gyro-compass C. Course selector pointer D. Steering wheel
Description : During the start-up of the circuit shown in the illustration, it is noted that the ends of component 'C' remain lighted but the tube does not illuminate. The cause of this problem is ____________. EL- ... ' is closed C. component 'C' is the wrong wattage D. component 'B' contacts are stuck closed
Description : The 'reset' contacts of the master switch shown in the illustration are ______________. EL-0102 A. closed only when the master switch is 'off' B. closed only when the master switch selects a 'run' condition C. opened separately by the winch operator D. opened when line voltage drops 10%
Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.
Description : If power were lost to the winch shown in the illustration while in 'second point hoist' the winch would stop. When power is restored the winch would ______________. EL-0102 A. continue to run at ' ... switch' is returned to 'off' closing the 'reset' contacts and then moved to any 'run' position
Description : How long after energizing 'ATMX' at '41Y' shown in the illustration do the contacts of 'ATM' operate? EL-0100 A. 3 minutes B. 27 minutes C. 30 minutes D. 33 minutes
Description : The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are ... board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield
Description : When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'
Description : Which of the devices shown in the illustration automatically prevents the simultaneous operation of the windlass from both master switches? EL-0073 A. Selector switch B. Contact 'CR1a' C. Contact 'CR2a' D. Contact 'CR1D'
Description : The only point in the steering stand shown in the illustration which needs periodic lubrication is the ______________. EL-0098 A. repeater assembly ball bearings B. steering wheel bearing C. operation selector switch D. course selector pointer
Description : The small circular symbols to which wire '52N57E' is connected at coordinates '57L' and '57P' shown in the illustration represent ___________________. EL-0100 A. relay contact solder points B. wire wrap connections C. terminal board screws D. switch contact terminals
Description : Which of the listed conditions occur when '4th point lower' is selected on the winch shown in the illustration? EL-0102 A. Master switch contacts '3', '4', '6', '8', '9', & '10' close. B. Contactors '2, 3, & 4M' and ' ... , '7', '8', and '9' close. D. Contactors '1 & 3M' and '1, 2, & 3A' pick up.
Description : Which of the listed conditions occur when selection is made for 'third point hoist' on the winch shown in the illustration? EL-0102 A. Master switch contacts '5', '6', '7', '8', and '9' close. B. Contactors '2M', ' ... ' and '2A' drop out. D. Master switch contacts '3','4', '6', '8', and '9' close.
Description : To stop the electric motor shown in the illustration, the stop button is depressed, causing ____________. EL-0012 A. coil 'MS' to become de-energized B. contacts 'CR1' and 'MR4' to open C. contacts 'MR1', 'MR2', and 'MR3' to open D. contacts 'MS1', 'MS2', and 'MS3' to open
Description : The purpose of the capacitor within component 'B' of the circuit shown in the illustration is to ____________. EL-0081 A. prolong the life of the component's contacts B. discharge the neon within ... the inductive reactance in the circuit D. store power to operate the circuit should 'D' open
Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs
Description : As shown in the illustration, 'H1' and 'H2' are ___________. EL-0058 A. fixed capacitors B. variable capacitors C. contacts, closed when the circuit is energized D. contacts, open when the circuit is energized
Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller
Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit
Description : An open-circuit fault between the pressure switch and the 'annunciator module' shown in the illustration would cause the alarm circuit to react in the same manner as if ___________. EL-0094 A. 3.5 ... below switch setting C. 50 PSI were applied to the 'setpoint module' D. the pressure switch closed
Description : As shown in the illustration, once the "LV" relay is energized for operation, what contacts must remain closed to maintain the "LV" relay energized when the control lever is moved away from the "off" or "stop" ... . B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.
Description : As shown in the illustration, what happens when 'A' is closed, 'B' is in position '2' and component 'E2' burns out? EL-0058 A. 'H' energizes and 'D' makes contact. B. 'F' goes out allowing 'G' to disconnect. C. 'G' sounds an alarm and 'F' illuminates. D. 'C' opens causing 'A' to also open.
Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'
Description : After turning on the fluorescent lamp shown in the illustration, you note that the ends of the tube alternately glow and becomce dark without illuminating the center. The most obable cause for ... the lamp D. component 'B' contacts are opening and closing thus prohibiting sufficient current flow
Description : Power necessary to operate the horn relay shown in the illustration ____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through the relay's contacts D. also lights lamps 'R' and 'T'
Description : During start-up of the circuit shown in the illustration, it is noted that the ends of component 'C' alternately glow and become dark without the tube illuminating. The most probable cause ... start the lamp D. component 'B' contacts are opening and closing thus prohibiting sufficient current flow
Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.
Description : The 'reset' contacts of the master switch shown in the illustration provides the winch controller with ___________. EL-0102 A. low voltage release B. overload protection C. low voltage protection D. high power factor correction
Description : As shown in the illustration, all 'MS' contacts are opened and closed by means of ________. EL-0073 A. operating coils B. magnets C. manual operation of the master switches D. solenoid switches
Description : What is the power rating safety factor for the light dimming rheostat shown in the illustration at '77H'? EL-0100 A. 1 B. 2 C. 3 D. 6
Description : As shown in the illustration, what is the meaning of the numbers in brackets [ ] at location '31/33U'? EL-0100 A. Four separate devices with these part numbers feed signals into this point. ... continues on those four pages and connects to devices at the indicated coordinates. D. None of the above.
Description : As shown in the illustration, 'B' is a ____________. EL-0058 A. single-pole, double-throw switch B. double-pole, single-throw switch C. double-pole, double-throw switch D. circuit breaker
Description : Component 'C' in section 'I' shown in the illustration represent ____________. EL-0093 A. a selectable holding coil arrangement B. a 'fuse blown' indicator circuit C. 'reset' and 'trouble' lamps D. a handset with switch and voice elements
Description : When replacing component 'B' of the circuit shown in the illustration, it is important to know that ____________. EL-0081 A. it is polarity sensitive and must be inserted as indicated on its ... provide the capacitor's initial charge D. it must match the circuit voltage and component 'C' wattage
Description : When changing out component 'B' of the circuit shown in the illustration, it is important to know that ____________. EL-0081 A. it is polarity sensitive and must be inserted as indicated on its ... provide the capacitor's initial charge D. it must match the circuit voltage and component 'C' wattage
Description : Regarding the illustrated electrical schematic, 'S1-P', 'S1-Q', and 'S1-R' represent ____________. EL-0016 A. capacitors B. normally-closed contacts C. normally-open contacts D. normally-closed pushbutton switches
Description : Refering to the illustrated schematic diagram, which of the following statements is true when the motor is running in the forward direction? EL-0011 A. Normally-open contacts '4-5' are closed. B. Current ... switch. C. Normally-closed contacts 'R' are open. D. The blowout coils must be closed.
Description : When the motor shown in the illustration is running and the stop button is pushed, which of the following statements will hold true? EL-0010 A. Coil 'M' will now be energized. B. Coil 'CR' will now be energized. C. Contact 'M' will close as contact 'CR' opens. D. Contacts 'M' and 'CR' will open.
Description : As shown in the illustration, which of the operations listed will happen when the 'jog button' is pushed? EL-0010 A. Coil 'CR' closes the normally open 'CR' contacts. B. Coil 'M' opens contact 'M'. C. Coil 'M' closes contact 'M'. D. Contact 'M' remains open despite the jog button being pushed.
Description : When the series field relay "FR" of the winch circuit shown in the illustration is energized during dynamic braking the _______________. EL-0102 A. shunt Field Relay "FR-B.O." is de-energized and contacts ... . shunt Field Relay "FR-B.O." opposes the series coil's flux and sets the mechanical brake