The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking

1 Answer

Answer :

Answer: A

Related questions

Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes

Last Answer : Answer: B

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes

Last Answer : Answer: B

Description : Modern DC generators are fitted with commutating poles to _____________. A. prevent motorizing B. reduce sparking C. reduce the load on the main poles D. reduce spring pressure on the brushes

Last Answer : Answer: B

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : If you reverse both the field and the armature connections to a DC propulsion motor, _____________. A. the direction of motor rotation will change B. the brushes will become overheated C. a magnetic lock will occur in the motor D. the direction of motor rotation will remain the same

Last Answer : Answer: D

Description : Which of the following are the parts of a DC generator that convert the AC in the armature to DC in the external circuit. Are these parts the: w) field poles x) slip rings and the brushes y) commutator and the brushes z) armature and the core

Last Answer : ANSWER: Y -- COMMUTATOR AND THE BRUSHES

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.

Last Answer : Answer: C

Description : Basic electrical motor action depends on _______________. A. a conductor rotated within a magnetic field B. a current carrying conductor placed in a magnetic field C. the relative force of the commutator and commutating poles D. the relative force of the armature and interpoles

Last Answer : Answer: B

Description : Sparking at the brushes of a running motor could be an indication of _____________. A. normal operation B. a dirty commutator C. increased brush capacity D. water vapor absorption

Last Answer : Answer: B

Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica

Last Answer : Answer: A

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : Which of the following components are used to convert alternating current produced in the generator windings to direct current? A. Armature and equalizer B. Commutator and brushes C. Rotor and interpoles D. Field and exciter

Last Answer : Answer: B

Description : Which of the listed conditions might contribute to very rapid wearing of a DC machine's commutator bars? A. A grounded commutator bar B. Using improper carbon brushes C. Aligning the front and rear mica V-rings improperly D. An open circuit in the armature

Last Answer : Answer: B

Description : Armature reaction in a dc motor causes a shift of the neutral plane in which direction?

Last Answer : Opposite the rotation.

Description : Which of the listed faults cannot be eliminated, EXCEPT by turning or grinding a commutator with a rigidly supported tool? A. Sparking brushes B. Eccentricity C. High mica D. Blackened commutator

Last Answer : Answer: B

Description : Sparking at the brushes of a DC propulsion motor can be the result of ____________. A. improper brush pressure B. improper brush seating C. reversed interpole polarity D. all of the above

Last Answer : Answer: D

Description : Which of the listed conditions could cause a DC motor to have excessively hot windings and sparking at the brushes? A. Reversed interpole polarity B. High bar-to-bar voltage C. Loose brushes D. Excessive humidity

Last Answer : Answer: A

Description : Insufficient brush pressure on a DC motor may cause _______. A. generator overload B. excess residual magnetism C. water vapor absorption D. sparking of the brushes

Last Answer : Answer: D

Description : Brush sparking during commutation may be caused by ________. A. eddy currents in the armature core B. laminations in the generator field pieces C. induced current opposite to coil inductance D. coil inductance discharge occurring at commutation

Last Answer : Answer: D

Description : What is the function of the interpoles installed in DC motors? A. To provide greater torque by strengthening the main field. B. To provide sparkless commutation without having to shift the brushes. C. To limit the production of counter-electromotive force. D. To limit the starting surge current.

Last Answer : Answer: B

Description : The direction of rotation of an induction motor is ________. A. opposite the rotating field direction B. the same as the direction of the rotating field C. determined by the number of poles D. determined by the staggering of the brushes

Last Answer : Answer: B

Description : State the function of following parts of DC motor : i) Yoke ii) Poles iii) Field winding iv) Commutator. 

Last Answer : Function : i) Yoke: The yoke serves the following two purposes. i) It supports the other components such as poles and provides mechanical protection for whole machine. ii) It forms a part of ... one pole to another and thus to help the motor to develop a continuous and unidirectional torque  

Description : What causes sparking between the brushes and the commutator?

Last Answer : Improper commutation.

Description : An open in the armature of a DC motor is suspected, but is not found by visual inspection of the commutator. The next step in troubleshooting this problem is to ________________. A. conduct a ... windings C. conduct an insulation resistance test of the armature D. test the commutator for a ground

Last Answer : Answer: A

Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator

Last Answer : Answer: B

Description : For a DC motor, what major component in addition to the field winding and the armature winding is necessary? w) a commutator x) a stator y) a battery z) a rotor

Last Answer : ANSWER: W -- A COMMUTATOR

Description : If an AC generator experiences voltage failure, the cause may be _____________. A. an open in the field circuit B. the brushes shifting out of the neutral plane C. excessive locked-rotor current D. a rotating slip ring

Last Answer : Answer: A

Description : A short circuit in the armature of a DC motor will cause the motor to _____________. A. run fast B. hum when energized C. spark at the brushes D. fail to start

Last Answer : Answer: C

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : 43 The purpose of providing an iron core in a transformer is to A.Provide support to windings B. Reduce hysteresis loss C. decrease the reluctance of the magnetic path D. reduce eddy current losses

Last Answer : C. Decrease the reluctance of the magnetic path

Description : The amount of mechanical force or torque produced by an electric motor depends on the ________________. A. strength of its magnetic field B. amount of armature current flow C. length of conductor in the field D. all of the above

Last Answer : Answer: D

Description : In general, D.C. propulsion motor brush sparking can be caused by _______________. A. incorrect brush grade, pressure or position B. a concentric commutator C. a dark chocolate colored commutator D. all of the above

Last Answer : Answer: A

Description : In D.C. motor construction, the armature coils' ends are _______________. A. soldered to the commutator bar risers B. imbedded into core slots C. crimped together with brush pigtails D. spliced with the field windings

Last Answer : Answer: A

Description : The purpose of DC generator brushes is to _____________. A. neutralize armature reaction B. conduct electric current to an outside circuit C. convert DC current to AC current D. provide excitation to a DC generator

Last Answer : Answer: B

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor? A. Higher than normal operating temperature. B. Excessive vibration at normal speed. C. Sparking at the brushes. D. High megger readings.

Last Answer : Answer: A

Description : Sparking of D.C. motor brushes can be caused by __________. A. an open commutating winding B. many mechanical, electrical or operating faults C. an open interpole D. all of the above

Last Answer : Answer: B

Description : Which of the damages listed can occur to the components of a winch master control switch, if the cover gasket becomes deteriorated? A. Overheating of the winch motor. B. Contamination of lube oil. C. Sparking at the winch motor brushes. D. Rapid corrosion of switch components.

Last Answer : Answer: D

Description : In an induction motor, rotor currents are circulated in the rotor by _____________. A. slip rings and brushes B. an armature and brushes C. inductive reaction of the rotating stator field D. external variable resistors

Last Answer : Answer: C

Description : In an AC generator, direct current from a separate source is passed through the windings of the rotor _____________. A. by means of slip rings and brushes B. by means of a commutator C. by means of rotating bar magnet D. to minimize the danger of arc over

Last Answer : Answer: A

Description : The current from the stator of an alternator is taken out to the external load circuit through (A) slip rings. (B) commutator segments. (C) solid connections. (D) carbon brushes.

Last Answer : (C) solid connections.

Description : In the illustrated test, if the lamp fails to light on any of the three windings then _________. EL-0027 A. all three windings are grounded and the motor should be sent out for repair B. ... the motor controller and the controller should be checked D. the test should be redone at a higher voltage

Last Answer : Answer: C

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : As compared to shunt and compound DC motors, the series DC motor will have the highest torque because of its comparatively ____________ at the start. (A) Lower armature resistance. (B) Stronger series field. (C) Fewer series turns. (D) Larger armature current.

Last Answer : (D) Larger armature current.

Description : Which of the following is a characteristic of fractional horsepower repulsion start motors? A. They start with a rotating stator field. B. The short circuiting ring is removed from the commutator while ... brushes are removed from the commutator while starting. D. They have a low starting torque.

Last Answer : Answer: B