The current from the stator of an alternator is taken out to the external load circuit
through
(A) slip rings. (B) commutator segments.
(C) solid connections. (D) carbon brushes.

1 Answer

Answer :

(C) solid connections.

Related questions

Description : Voltage generated by most AC generators is fed from the machine to the bus by means of ____________. A. brushes on a commutator B. brushes on slip rings C. slip rings on a commutator D. direct connections from the stator

Last Answer : Answer: D

Description : Which of the following are the parts of a DC generator that convert the AC in the armature to DC in the external circuit. Are these parts the: w) field poles x) slip rings and the brushes y) commutator and the brushes z) armature and the core

Last Answer : ANSWER: Y -- COMMUTATOR AND THE BRUSHES

Description : In an induction motor, rotor currents are circulated in the rotor by _____________. A. slip rings and brushes B. an armature and brushes C. inductive reaction of the rotating stator field D. external variable resistors

Last Answer : Answer: C

Description : In D.C. generators, current to the external circuit from armature is given through (a) commutator (b) solid connection (c) slip rings (d) none of above

Last Answer : Ans: a

Description : In an AC generator, direct current from a separate source is passed through the windings of the rotor _____________. A. by means of slip rings and brushes B. by means of a commutator C. by means of rotating bar magnet D. to minimize the danger of arc over

Last Answer : Answer: A

Description : An alternator will fail to produce line voltage as a result of _____________. A. a closed circuit breaker B. oxidized slip rings C. improperly staggered brushes D. exciter generator failure

Last Answer : Answer: D

Description : The current from the stator of an alternator is taken out to the external load circuit through: (A) slip rings (B) commutator segments (C) solid connections (D) carbon brushes

Last Answer : D  is correct

Description : Which of the listed conditions might contribute to very rapid wearing of a DC machine's commutator bars? A. A grounded commutator bar B. Using improper carbon brushes C. Aligning the front and rear mica V-rings improperly D. An open circuit in the armature

Last Answer : Answer: B

Description : In actual applications, electrical connections to 'R1-R2' of figure 'A' and to 'R1-R2- R3' of figure 'B' shown in the illustration are made by ______________. EL-0092 A. soldered contacts B. spliced and taped connections C. slip rings and brushes D. solderless crimp-on connectors

Last Answer : Answer: C

Description : Etched or burned bands on the contact faces of the brushes in a direct current generator can be caused by ____________. A. high mica segments B. copper drag on the commutator C. brushes improperly positioned D. copper embedded in the brushes

Last Answer : Answer: C

Description : Which of the following statements is true concerning all three-phase alternators? A. Each has three separate but identical armature windings acted on by one system of rotating magnets. B. Each has one ... The three phases always provide power to the load through three sets of slip rings and brushes.

Last Answer : Answer: A

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : Which of the following is a characteristic of fractional horsepower repulsion start motors? A. They start with a rotating stator field. B. The short circuiting ring is removed from the commutator while ... brushes are removed from the commutator while starting. D. They have a low starting torque.

Last Answer : Answer: B

Description : When an alternator is to remain idle for even a few days _________________. A. lift the brushes and disconnect the pigtails B. insulate the collector rings with strips of cardboard C. energize the heater circuit D. open the equalizing bus disconnect switch

Last Answer : Answer: C

Description : Which of the following statements represents the FIRST step in seating new brushes on slip rings? A. Wrap sandpaper around the slip rings and slide it back and forth between the brushes and the slip rings. B. ... to 4 hours. D. Apply seating compound under the brushes and run at no load for 2 hours.

Last Answer : Answer: A

Description : In the illustrated test, if the lamp fails to light on any of the three windings then _________. EL-0027 A. all three windings are grounded and the motor should be sent out for repair B. ... the motor controller and the controller should be checked D. the test should be redone at a higher voltage

Last Answer : Answer: C

Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes

Last Answer : Answer: B

Description : To properly seat the brushes on slip rings, you should use ____________. A. sand paper B. crocus cloth C. emery cloth D. all of the above

Last Answer : Answer: A

Description : The reversal of an AC, three-phase, induction motor is accomplished by ______________. A. changing all three motor leads B. reversing the position of the slip rings C. interchanging any two of the three motor leads D. interchanging any two brushes

Last Answer : Answer: C

Description : Brushless generators are designed to operate without the use of ___________. A. brushes B. slip rings C. commutators D. all of the above

Last Answer : Answer: D

Description : What are the materials used to manufacture the brushes for slip rings of an induction motor?

Last Answer : A:The slip rings are made of brass and phosphor bronze. The brushes are made of metal graphite which is an alloy of copper and carbon.

Description : A three-phase, squirrel cage, induction motor will run hot due to _____________. A. open stator coils B. high power factor C. dirty or corroded slip rings D. reversed commutating poles

Last Answer : Answer: A

Description : The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking

Last Answer : Answer: A

Description : Erratic operation of the devices represented in the diagrams shown in the illustration could be traced to ____________. EL-0092 A. improper contact at 'R' slip rings or 'S' connections B. a low three- ... . improper contact at 'S' slip rings or 'R' connections D. a high three-phase voltage supply

Last Answer : Answer: A

Description : Routine maintenance of a ship's service alternator should include ______________. A. changing the pedestal bearing insulation yearly B. megger testing of all rectifying diodes C. lubricating excitation slip rings D. periodic cleaning of the air filters or screens

Last Answer : Answer: D

Description : If an AC generator experiences voltage failure, the cause may be _____________. A. an open in the field circuit B. the brushes shifting out of the neutral plane C. excessive locked-rotor current D. a rotating slip ring

Last Answer : Answer: A

Description : Which of the following statements describes what will occur if the motor shown in the illustration is required to carry 150% of full load? EL-0056 A. The primary counter emf will be increased. B. ... slip will decrease. D. The slip value, stator current curve, and torque curve will all coincide.

Last Answer : Answer: B

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : Which of the listed conditions will occur if dirt and grease are allowed to accumulate between the commutator segments of a motor? A. A partial short circuit. B. A dead short circuit. C. Misalignment of the motor shaft. D. Overspeeding of the motor.

Last Answer : Answer: A

Description : Which of the following components are used to convert alternating current produced in the generator windings to direct current? A. Armature and equalizer B. Commutator and brushes C. Rotor and interpoles D. Field and exciter

Last Answer : Answer: B

Description : In the illustration, the signal from the device connected to terminals 18 and 19 is __________. EL-0046 A. prime mover speed feedback B. loss of control alarm when comparing with the input signal ... slip between the prime mover and the alternator D. to shut down the prime mover if overspeeding

Last Answer : Answer: A

Description : Voltage failure of an AC generator may be caused by ____________. A. failure of the exciter generator B. a tripped bus circuit breaker C. high mica segments on the stator bus bar D. excessive prime mover speed

Last Answer : Answer: A

Description : A solid-state circuit is inoperative; the FIRST action that should be taken is to ____________. A. wiggle all the components to check for loose connections B. check all the resistors C. change all transistors D. check the DC supply voltage

Last Answer : Answer: D

Description : A 3-phase 50HZ SCIM takes a power input of 30 KW at its full load speed of 1440 rpm. Total stator losses are 1 KW. The slip and rotor ohmic losses at full load are a) 0.02, 600 W b) 0.04, 580 W c) 0.04, 1160 W d) 0.04, 1200 W

Last Answer : Ans: 0.04, 1160 W

Description : State the function of following parts in Induction motor. (i) Stator (ii) Slip rings

Last Answer : Name of part Function Stator 1) Stator frame supports the core, terminal box and protects the inner parts. 2) Stator core houses stator winding. 3) Stator winding ... ) Provides facility to connect external resistance to rotor circuit through brushes for starting and control.

Description : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the ... frequency of induced voltage across slip ring is A) 30 Hz B) 70 Hz C) 20 Hz D) 35 Hz

Last Answer : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the normal direction, The frequency of induced voltage across slip ring is 70 Hz

Description : A degree of control over the speed of a slip ring induction motor can be obtained by _____________. A. adjusting governor linkage B. changing the number of phases to the motor C. inserting resistance into the stator circuit D. inserting resistance into the rotor circuit

Last Answer : Answer: D

Description : Which of the diagrams shown in the illustration depicts the proper method of aligning brushes on a commutator? EL-0057 A. A B. B C. C D. D

Last Answer : Answer: B

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : Sparking at the brushes of a running motor could be an indication of _____________. A. normal operation B. a dirty commutator C. increased brush capacity D. water vapor absorption

Last Answer : Answer: B

Description : Which of the listed faults cannot be eliminated, EXCEPT by turning or grinding a commutator with a rigidly supported tool? A. Sparking brushes B. Eccentricity C. High mica D. Blackened commutator

Last Answer : Answer: B

Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes

Last Answer : Answer: B

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : An alternator operating in parallel begins to vibrate severely and eventually trips out on the reverse power relay. The cause of the vibration was a result of ______________________. A. the ... C. the alternator was operating out of synchronism D. flashover at the alternator collector rings

Last Answer : Answer: C

Description : _____ brushes are fragile and cause excessive wear of commutator, (a) Natural graphite (b) Hard carbon (c) Electro graphitic (d) Metal graphite

Last Answer : (a) Natural graphite

Description : The material for commutator brushes is generally (a) mica (b) copper (c) cast iron (d) carbon

Last Answer : Ans: d

Description : A synchro has (A) a 3-phase winding on rotor and a single-phase winding on stator. (B) a 3-phase winding on stator and a commutator winding on rotor. (C) a 3-phase winding on stator and a single-phase winding on rotor. (D) a single-phase winding on stator and a commutator winding on rotor.

Last Answer : Ans: C Synchros : The basic synchro unit called a synchro transmitter. It’s construction similar to that of a Three phase alternator.