An open-circuit fault between the pressure switch and the 'annunciator module' shown in the illustration would cause the alarm circuit to react in the same manner as if ___________. EL-0094 A. 3.5 volts were applied to the 'setpoint module' B. 'reduction gear lube oil pressure' fell below switch setting C. 50 PSI were applied to the 'setpoint module' D. the pressure switch closed

1 Answer

Answer :

Answer: B

Related questions

Description : What is the purpose of the 'annunciator module' (6000F35) shown in the illustration? EL-0094 A. Provide an input to the setpoint module. B. Drive the alarm lamp and, through the controller, the horn. ... and +24 volts to their respective power supplies. D. Connect 24 volts to both sides of the horn.

Last Answer : Answer: B

Description : What is the purpose of either 'setpoint module' (6000F090/030) shown in the illustration? EL-0094 A. Program the 'signal conditioner' as to how to vary its input. B. Supply 0 - 10 volts to ... . Obtain an input from the 'signal conditioner' and, if outside set limits, signals the 'annunciator'.

Last Answer : Answer: D

Description : As shown in the illustration, which set of conditions, evident to the operator and the 'setpoint module' respectively, will result in a high exhaust temperature alarm on the 'starboard main engine'? EL-0094 A. 50°F and 3.3 volts B. 180°F and 6.0 volts C. 750°F and 0-10 volts D. 900°F and 7.5 volts

Last Answer : Answer: D

Description : Which sensor shown in the illustration develops its own conditioning and point setting and 'reports' directly to the 'annunciator'? EL-0094 A. Transducer B. Resistance Temperature Detector (RTD) C. Pressure Switch D. Thermocouple

Last Answer : Answer: C

Description : The +5 volt regulated power supply shown in the illustration is fed directly from the _______________. EL-0094 A. 115 volt AC bus B. Annunciator Module C. +24 volt supply D. Annunciator Controller

Last Answer : Answer: C

Description : Which plant parameters shown in the illustration would produce an alarm if they fell below preset values? EL-0094 A. SME #7 CYL. EXH. and L.O. PRESS. TO RDCN. GR. B. L.O. PRESS TO MN. ENG. and PME #3 MN. BRG. C. ... . TO MN. ENG and L.O. PRESS. TO RDCN. GR. D. PME #3 MN. BRG. and SME #7 CYL. EXH.

Last Answer : Answer: C

Description : Which plant parameters shown in the illustration would produce an alarm if they exceeded preset values? EL-0094 A. SME #7 CYL. EXH. and L.O. TO RDCN. GR. B. L.O. PRESS. TO MN. ENG. and PME #3 MN. BRG. C. L.O. PRESS. TO MN. ENG. and L.O. TO RDCN. GR. D. PME #3 MN. BRG. and SME #7 CYL. EXH.

Last Answer : Answer: D

Description : If the 'E/P converter' shown in the illustration operated on a range of 1-9 volts and 6-30 PSI, a 5 volt input would yield ______________. EL-0096 A. 9 PSI B. 15 PSI C. 18 PSI D. 24 PSI

Last Answer : Answer: C

Description : What type of service is NOT provided by the circuit shown in the illustration? EL-0094 A. Logging of engine order signals from the bridge. B. Printed record of alarms as they ... . Visual metering of temperature and pressure conditions. D. Periodic recording of pressure and temperature conditions.

Last Answer : Answer: A

Description : As shown in the illustration, 'H1' and 'H2' are ___________. EL-0058 A. fixed capacitors B. variable capacitors C. contacts, closed when the circuit is energized D. contacts, open when the circuit is energized

Last Answer : Answer: D

Description : As shown in the illustration, what happens when 'A' is closed, 'B' is in position '2' and component 'E2' burns out? EL-0058 A. 'H' energizes and 'D' makes contact. B. 'F' goes out allowing 'G' to disconnect. C. 'G' sounds an alarm and 'F' illuminates. D. 'C' opens causing 'A' to also open.

Last Answer : Answer: C

Description : How many different D.C. voltages are required to operate the circuit shown in the illustration? EL-0094 A. Two B. Three C. Four D. Five

Last Answer : Answer: C

Description : If the line voltage to the controller shown in the illustration is 440 volts, what is applied across the control circuit? EL-0080 A. 110 volts B. 220 volts C. 440 volts D. 660 volts

Last Answer : Answer: C

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : During the start-up of the circuit shown in the illustration, it is noted that the ends of component 'C' remain lighted but the tube does not illuminate. The cause of this problem is ____________. EL- ... ' is closed C. component 'C' is the wrong wattage D. component 'B' contacts are stuck closed

Last Answer : Answer: D

Description : If 450 volts AC were measured across the load as shown in the illustration it would indicate a/an _______________. EL-0083 A. open winding between 'H1' and 'X1' B. properly operating circuit C. open winding between 'X1' and 'X4' D. ground on one side of 'Ep'

Last Answer : Answer: C

Description : As shown in the illustration, the symbol is used in electrical drawings to designate a ____________. EL-0026 A. limit switch with one set of normally open contacts B. maintaining type ... type push button with a mechanical interlock D. normally closed contact held open mechanically by an interlock

Last Answer : Answer: C

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'TEST' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: B

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'OFF' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: A

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'ON' position, contacts '3,4' and '7,8' are respectively ______________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: D

Description : 'A-1', as shown in the illustration, is/are ____________. EL-0017 A. normally-closed overload relay contacts B. a double pole knife switch C. normally-open overload relay contacts D. a single pole knife switch

Last Answer : Answer: A

Description : The turns ratio of transforme 'A' shown in the illustration is four to one and all taps are evenly spaced. If 110 volts were applied to terminals 'X1' and 'X3', what would be indicated across 'H1' and 'H2'? EL-0082 A. 37.5 volts B. 55 volts C. 220 volts D. 440 volts

Last Answer : Answer: C

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 110 volts were applied to terminals 'X1,3' and 'X2,4', what would be indicated across 'H1' and 'H2'? EL-0082 A. 27.5 volts B. 55 volts C. 220 volts D. 440 volts

Last Answer : Answer: D

Description : The turns ratio of device 'A' shown in the illustration is four to one and all taps are evenly spaced. If 110 volts were applied to terminals 'X1' and 'X3', what would be indicated across 'H1' and 'H2'? EL-0082 A. 37.5 volts B. 55 volts C. 220 volts D. 440 volts

Last Answer : Answer: C

Description : The turns ratio of transformer 'A' shown in the illustration is four to one and all taps are evenly spaced. If 120 volts were applied to terminals 'H1' and 'H3', what would appear at 'X1' and 'X2'? EL-0082 A. 15 volts B. 30 volts C. 480 volts D. 960 volts

Last Answer : Answer: A

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 220 volts were applied to terminals 'H1' & 'H2', what would be indicated across 'X1' & 'X4' with 'X2' & 'X3' connected and isolated? EL-0082 A. 55 volts B. 110 volts C. 220 volts D. 440 volts

Last Answer : Answer: B

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 440 volts were applied to terminals 'H1' & 'H2', what would be indicated across 'X1' & 'X4' with 'X2' & 'X3' connected and isolated? EL-0082 A. 110 volts B. 220 volts C. 880 volts D. 1760 volts

Last Answer : Answer: B

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 220 volts were applied to terminals 'H1' and 'H2', what would be indicated across 'X3' and 'X4'? EL-0082 A. 55 volts B. 110 volts C. 440 volts D. 880 volts

Last Answer : Answer: A

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 440 volts were applied to terminals 'H1' and 'H2', what would be indicated across 'X1,3' and 'X2,4'? EL-0082 A. 55 volts B. 110 volts C. 220 volts D. 880 volts

Last Answer : Answer: B

Description : The turns ratio of device 'A' shown in the illustration is four to one and all taps are evenly spaced. If 120 volts were applied to terminals 'H1' and 'H3', what would appear at 'X1' and 'X2'? EL-0082 A. 15 volts B. 30 volts C. 480 volts D. 960 volts

Last Answer : Answer: A

Description : The turns ratio of device 'A' shown in the illustration is four to one and all the taps are equally spaced. If 120 volts were applied between 'X1' and 'X2', what would be indicated across 'H1' and 'H4'? EL-0082 A. 30 volts B. 120 volts C. 480 volts D. 1440 volts

Last Answer : Answer: D

Description : The turns ratio of device 'A' shown in the illustration is four to one and all taps are equally spaced. If 440 volts were applied between 'H1' and 'H4', what would appear across 'X1' and 'X4'? EL-0082 A. 110 volts B. 220 volts C. 440 volts D. 1760 volts

Last Answer : Answer: A

Description : The sensor connected to 'signal conditioner' (6000F125) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: B

Description : The sensor connected to 'signal conditioner' (6000AH170) shown in the illustration is a/an _____________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: A

Description : The sensor connected to 'signal conditioner' (6000F085) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: D

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : The purpose of the 'heater resistors' for the winch circuit shown in the illustration is to _______________. EL-0102 A. limit the current in the heater circuit B. dispel moisture in the ' ... panel C. keep the winch brake housing below the dew point D. maintain winch motor operating temperature

Last Answer : Answer: B

Description : As shown in the illustration if the applied voltage is 12 VDC, the resistance of R1 is 110 ohms, and R2 is 10 kohms what is the voltage measured across R1 EL-0036 A. 11.86 volts B. .131 volts C. 12 volts D. .673 volts

Last Answer : Answer: B

Description : If the line voltage to the controller shown in the illustration is 440 volts, what voltage is applied across the motor when contacts 'S' close? EL-0080 A. 110 volts B. 220 volts C. 440 volts D. 660 volts

Last Answer : Answer: B

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : In order to prevent the winch shown in the illustration from turning while troubleshooting the controller circuit, _________________. EL-0102 A. set the dynamic brake by clamping contact 'DB' closed B. set the ... at 'B1' and 'B2' D. open the test link preventing current flow to the armature

Last Answer : Answer: D

Description : In the illustration, the component VR2 on the A1 AMPLIFIER MODULE is _________. EL-0060 A. a zener diode to regulate the +9 volt power supply from common B. a variable resistor diode to control the output to terminal ... 2 at 9.1 volts DC D. a tunnel diode with a breakdown voltage of 6.6 Volts DC

Last Answer : Answer: C