A fuse will blow for all the listed reasons EXCEPT ________. A. excessive vibration B. extremely hot surroundings C. loose fuse clips D. low contact resistance within the fuse

1 Answer

Answer :

Answer: D

Related questions

Description : In addition to short circuits and sustained overloads, fuses are likely to blow due to _____________. A. loose fuse clips B. low ambient temperatures C. low contact resistance D. all of the above

Last Answer : Answer: A

Description : Which of the listed conditions could cause a DC motor to have excessively hot windings and sparking at the brushes? A. Reversed interpole polarity B. High bar-to-bar voltage C. Loose brushes D. Excessive humidity

Last Answer : Answer: A

Description : When replacing fuses, always make sure _______________. A. to stand on a rubber mat and use rubber gloves B. to use insulated pliers or screwdriver C. the fuse clips are straight, tight, and in good contact D. to increase the fuse rating 10% to guard against 'nuisance blowing'

Last Answer : Answer: C

Description : Excessive heat in an operating motor controller can result from _____________. A. a closed starter contact B. loose connections C. missing arc chutes D. low motor starting torque

Last Answer : Answer: B

Description : Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor? A. Higher than normal operating temperature. B. Excessive vibration at normal speed. C. Sparking at the brushes. D. High megger readings.

Last Answer : Answer: A

Description : On a vessel with turbo-electric drive, which of the following conditions would indicate that the propulsion motor had dropped out of synchronization with the propulsion generator? A. Excessive ... Tripped main motor interlocks C. Overheated crosstie busses D. Closed contact in the field circuits

Last Answer : Answer: A

Description :  Answer the following S. No Statement Chose the correct  answer OR Fill-in-the-blanks 1 Fyrite measures CO2, O2 and SO2 True/False 2 Ultrasonic Flow Meter uses the principle of____& ____ Fill in the ... of RPM  meter is used and for a visible shaft-end _______ type of  RPM meter is used.

Last Answer : Sr  No Statement Chose the correct  answer OR Fill-in-the-blanks Solution 1 Fyrite measures CO2, O2 and  SO2 True/False False 2 Ultrasonic Flow Meter uses the  principle of____& ____ ... ]  10 In a gasification system the  reduction zone is above the  combustion zone True/False False

Description : If the motor fails to start and a voltmeter reading between 1 and 6, as illustrated, indicates line voltage, your next step should be to ________. EL-0007 A. replace fuse '10a' B. replace or repair contact 'Ma' C. reset and determine the cause of the overload D. check line voltage between L1 and L3

Last Answer : Answer: C

Description : Which of the listed items will stop a motor due to a reduction in voltage and restart it when the voltage is restored to normal? A. Low voltage protection circuit B. Non-renewable link fuse C. Renewable link fuse D. Low voltage release circuit

Last Answer : Answer: D

Description : Which of the following statements is true concerning the cleaning of electrical contacts? A. Compressed air should be used to blow out metallic dust. B. Magnetic brushes should be used to remove ... contact resistance. D. Delicate parts should be cleaned with a brush and an approved safety solvent.

Last Answer : Answer: D

Description : A fuse will 'blow' if _____________. A. an electric motor is stopped suddenly by opening a switch B. the flow of current to the protection device is reversed C. the electrical current exceeds the rated value of the fuse D. unequal resistors are connected in parallel

Last Answer : Answer: C

Description : Which of the following conditions is most likely to occur if a single element fuse were used to replace a blown dual element fuse in a motor controller circuit? A. The fuse will blow when the motor ... overheats at high motor loads. C. The motor runs at reduced voltage. D. The motor runs normally.

Last Answer : Answer: A

Description : Which of the following conditions can lead to the failure of a resistor? A. Excessive vibration B. Insufficient ventilation C. Corrosion D. All of the above

Last Answer : Answer: D

Description : Grounds occurring in electrical machinery as a result of insulation failure may result from _____________. A. deterioration through extended use B. excessive heat C. extended periods of vibration D. all of the above

Last Answer : Answer: D

Description : Consider the following statements: Air vessels are fitted on the suction and delivery sides of a reciprocating pump to 1. Achieve higher speed without separation. 2. Reduce work in overcoming frictional resistance. 3. Avoid excessive vibration ... 2 & 3 only (c) 2, 3 & 4 only (d) 1, 2, 3 & 4

Last Answer : (d) 1, 2, 3 & 4

Description : Magnetic controller contacts may become welded together during operation because of _____________. A. excessive magnetic gap B. low contact pressure C. an open coil D. excessive ambient temperature

Last Answer : Answer: B

Description : Magnetic controller contacts may become welded together during operation due to _____________. A. an open coil B. low contact pressure C. excessive ambient temperature D. excessive magnetic gap

Last Answer : Answer: B

Description : A delayed-action fuse is most frequently used in which of the listed circuits? A. Lighting circuit B. Motor circuit C. Electric heater circuit D. Radar circuit

Last Answer : Answer: B

Description : If the contacts of a motor starter or controller fail to drop out when the 'stop' button is depressed the ____________. A. contacts are carrying excessive current B. contacts have become welded together C. shading coil is broken D. shading coil is loose

Last Answer : Answer: B

Description : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should (a) have low contact resistance (b) be clean and smooth (c) be of sufficient size and proper shape (d) have all above properties

Last Answer : (d) have all above properties

Description : Which of the procedures listed could result in damaging a transistor beyond repair? A. Applying incorrect polarity to the collector circuit. B. Applying excessive voltage to the input circuit. C. Careless soldering which would overheat the transistor. D. All of the above.

Last Answer : Answer: D

Description : Due to which of the following reasons the cables should not be operated too hot ? (a) The oil may loose its viscosity and it may start drawing off from higher levels (b) Expansion of the ... instability may rise due to the rapid increase of dielectric losses with temperature (e) All of the above

Last Answer : (e) All of the above

Description : What are the reasons for vibration in the motor?  

Last Answer : Vibration could be because of mechanical faults and electrical faults. 1. Mechanical faults. a. Wrong alignment of the motor on foundation. b. Wrong installation. c. Improper fitting ... on the vibration of twice the slip frequency developed due to irregular air gap. 

Description : From the standpoint of safety, you should never allow salt water to enter a leadacid storage battery or come in contact with sulfuric acid because ______________. A. the resulting gas is ... peroxide D. combining salt water with lead-acid creates an invisible gas resulting in severe corrosion

Last Answer : Answer: B

Description : You are using a mechanical voltage tester to check the fuses in a three-phase circuit supplying an electric motor. For which of the following reasons must the motor be stopped during the test? A. ... circuit would be indicated by the voltage tester with the circuit energized. D. All of the above.

Last Answer : Answer: B

Description : What is represented by the electric symbol figure 'D' in the illustration? EL-0005 A. Fuse B. Plug-in contact resistor C. Variable capacitor D. Electrolytic capacitor

Last Answer : Answer: A

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck

Last Answer : Answer: A

Description : In damped vibrations, the amplitude of the resulting vibration gradually reduces. This is due to the reason that an amount of energy is always dissipated to overcome the ________ * 1 point (A) Frictional resistance (B) Work done(C) Fluid pressure (D) Air pressure

Last Answer : (A) Frictional resistance

Description : In damped vibrations, the amplitude of the resulting vibration gradually reduces. This is due to the reason that an amount of energy is always dissipated to overcome the ________ a) Frictional resistance b) Work done c) Fluid pressure d) Air pressure

Last Answer : a) Frictional resistance

Description : Using a fuse whose rating is higher than necessary ________. A. endangers the apparatus it is supposed to protect B. reduces the possibility of short circuits C. increases the efficiency of the equipment by allowing more current to be used D. wastes money because they are more expensive

Last Answer : Answer: A

Description : Why will too many electrical devices operating at one time after blow a fuse or trip a circuit breaker?

Last Answer : The load exceeds the limit of the breaker or fuse. For example a20 amp breaker on a 120 volt circuit will handle 2400 watts. Exceedthat wattage and the breaker will trip or the fuse will blow.

Description : A testing device called a 'growler' is being used to locate a shorted coil in the stator of an AC electrical machine. When the 'feeler' is moved over a slot containing the shorted coil _____________. ... . the meter needle will be deflected to zero D. the meter needle will be deflected to full-scale

Last Answer : Answer: A

Description : Due to which of the following factors the brush wear rate is altered ? (a) Speed of the machine (b) Contact pressure (c) Surface conditions of brush and commutator (d) Excessive sparking (e) All of the above

Last Answer : Ans: E

Description : The air gap in an induction motor should be checked periodically with a feeler gage to detect ____________. A. rotor contact with the laminations B. changes in armature magnetic strength C. excessive bearing wear D. electrical damage to the rotor

Last Answer : Answer: C

Description : A loud buzzing noise at the contacts of a magnetic controller could indicate _____________. A. weak contact spring pressure B. misalignment of the magnet faces C. excessive line current D. mechanical binding

Last Answer : Answer: B

Description : The pitting of controller contacts can be caused by _____________. A. excessive spring pressure B. insufficient contact pressure C. continuous motor overload D. all of the above

Last Answer : Answer: B

Description : Which of the following option is incorrect about the sludges? a) Sludges are soft, loose and slimy precipitate b) They are non-adherent deposits and can be easily removed c) Formed generally at heated portions of the boiler d) Can be removed by blow down operation

Last Answer : c) Formed generally at heated portions of the boiler

Description : One of the generator or motor bearings is generally insulated from the end housing in order to prevent ________. A. rapid brush wear B. current leakage from the shaft C. excessive field winding heat D. circulation of shaft currents induced in the machine's frame

Last Answer : Answer: D

Description : If a fuse of correct size and type blows frequently, ________________. A. try the next higher amperage rating B. try the next lower amperage rating C. look for trouble within the circuit D. reduce the applied voltage 10%

Last Answer : Answer: C

Description : As shown in the illustration, which of the operations listed will happen when the 'jog button' is pushed? EL-0010 A. Coil 'CR' closes the normally open 'CR' contacts. B. Coil 'M' opens contact 'M'. C. Coil 'M' closes contact 'M'. D. Contact 'M' remains open despite the jog button being pushed.

Last Answer : Answer: C

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : If the motor shown in the illustration will not start when 'Q' is depressed, which of the listed components should be checked FIRST? EL-0017 A. Fuses 'F-1' and 'F-2'. B. Operating coil 'C'. C. Contacts 'H-1', 'H-2', and 'H-3'. D. Contact 'H-4'.

Last Answer : Answer: A

Description : If the circuit shown in the illustration were energized and operating properly, which of the devices listed would be open? EL-0007 A. The stop push-button B. The start push-button C. Contact 'Ma' D. Contact 'OL1'

Last Answer : Answer: B

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : Since fuse elements are made of zinc or any alloy of tin and lead, the melting point of the fuse element must be _____________. A. higher than that of copper B. lower than that of copper C. equal to that of copper D. reached when the conductor it is protecting becomes 'white hot.'

Last Answer : Answer: B