The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are operated by the same relay coil B. screw connections are on terminal board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield

1 Answer

Answer :

Answer: B

Related questions

Description : The small circular symbols to which wire '52N57E' is connected at coordinates '57L' and '57P' shown in the illustration represent ___________________. EL-0100 A. relay contact solder points B. wire wrap connections C. terminal board screws D. switch contact terminals

Last Answer : Answer: C

Description : The contacts operated by the D.C. relay coil shown in the illustration are located in the schematic diagram prints at coordinates ____________. EL-0100 A. '41Y' on this page B. '52M52M' and '52H35M' C. '57R' on this page D. '52N' on page '57R'

Last Answer : Answer: C

Description : What do the arrow-like symbols at coordinate '33J' shown in the illustration represent? EL-0099 A. Connection to ground. B. Connection to the analog common bus. C. Plug-in connection. D. Screw connection on a terminal board.

Last Answer : Answer: C

Description : The devices located at coordinates '49W' in the illustration represents a/an _________. EL-0100 A. A.C. motor B. A.C. relay coil C. D.C. motor D. D.C. buzzer

Last Answer : Answer: B

Description : The device at coordinates '63/1' in the illustration represents a/an _____________. EL-0100 A. A.C. buzzer B. A.C. motor C. D.C. motor D. D.C. relay coil

Last Answer : Answer: D

Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'

Last Answer : Answer: C

Description : The symbol at coordinates '15R' in the illustration indicate a connection to ___________. EL-0100 A. the analog circuitry common bus B. ground C. the vessel's hull D. the console's chassis

Last Answer : Answer: A

Description : The symbol at coordinates '11R' in the illustration indicate a connection to _____________. EL-0100 A. ground B. the console chassis C. the digital circuitry common bus D. earth through the vessel's hull

Last Answer : Answer: C

Description : The 'safe switch' of the winch controller shown in the illustration is operated _______________. EL-0102 A. through the master switch handle B. when heater circuit current is high C. by contactor coil 'FR' D. manually by the winch operator

Last Answer : Answer: D

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : For console circuit card 'LLEA' as shown in the illustration at coordinates '63R/S', the input(s) and output(s) are respectively on pin numbers ____________. EL-0100 A. '5' and '3' & '4' B. '2' & '3' and '5' & '6' C. '5' & '6' and '2' & '3' D. '3' & '4' and '5'

Last Answer : Answer: D

Description : As shown in the illustration, what is the meaning of the numbers in brackets [ ] at location '31/33U'? EL-0100 A. Four separate devices with these part numbers feed signals into this point. ... continues on those four pages and connects to devices at the indicated coordinates. D. None of the above.

Last Answer : Answer: C

Description : How long after energizing 'ATMX' at '41Y' shown in the illustration do the contacts of 'ATM' operate? EL-0100 A. 3 minutes B. 27 minutes C. 30 minutes D. 33 minutes

Last Answer : Answer: D

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'TEST' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: B

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'OFF' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: A

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'ON' position, contacts '3,4' and '7,8' are respectively ______________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: D

Description : What does the arrangement at coordinates '62E' shown in the illustration represent? EL-0099 A. Position recording drum and stylus B. Temperature compensating thyristor C. Miniature bridge rectifier D. Twisted wire pair within a shield

Last Answer : Answer: D

Description : If 450 volts AC were measured across the load as shown in the illustration it would indicate a/an _______________. EL-0083 A. open winding between 'H1' and 'X1' B. properly operating circuit C. open winding between 'X1' and 'X4' D. ground on one side of 'Ep'

Last Answer : Answer: C

Description : In actual applications, electrical connections to 'R1-R2' of figure 'A' and to 'R1-R2- R3' of figure 'B' shown in the illustration are made by ______________. EL-0092 A. soldered contacts B. spliced and taped connections C. slip rings and brushes D. solderless crimp-on connectors

Last Answer : Answer: C

Description : Batteries 'A' and 'B' shown in the illustration are 6 volts each and batteries 'C' and 'D' are 24 volts each. If 'A' were connected in series-opposing to 'C' and 'B' was similarly ... the top terminal C. 30 volts, negative at the bottom terminal D. 30 volts, positive at the bottom terminal

Last Answer : Answer: A

Description : Batteries 'A' and 'B' shown in the illustration are 6 volts each and batteries 'C' and 'D' are 24 volts each. If 'A' and 'B' were reconnected to be in series-opposing to 'C' and 'D' ... at the top terminal C. 30 volts, negative at the bottom terminal D. 30 volts, positive at the bottom terminal

Last Answer : Answer: A

Description : In the illustration, the tan and white wires are connected to the solenoid valve. The solinoid valve is_________. EL-0043 A. in the liquid line before the TXV B. energized and open whenever the unit ... so the unit must be modified before using aboard ship D. the water inlet for the ice maker

Last Answer : Answer: D

Description : In the illustration, the tan and white wires are connected to the solenoid valve. The solenoid valve is_________. EL-0042 A. in the liquid line before the TXV B. energized and open whenever the unit ... so the unit must be modified before using aboard ship D. the water inlet for the ice maker

Last Answer : Answer: D

Description : If coil 'R1-R2' at the receiver of figure 'A' shown in the illustration were in 180 degree error with respect to that of the transmitter, what corrective action should be taken? EL-0092 A. No action is ... and 'R2'. C. Interchange connections 'S1' and 'S2'. D. Interchange connections 'S1' and 'S3'.

Last Answer : Answer: B

Description : If coil 'R1-R2' at the receiver of figure 'A' shown in the illustration turned opposite of that in the transmitter, what corrective action should be taken? EL-0092 A. No action is necessary as this is ... . C. Interchange connections to 'S1' and 'S2'. D. Interchange connections to 'S1' and 'S3'.

Last Answer : Answer: D

Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : 'A-1', as shown in the illustration, is/are ____________. EL-0017 A. normally-closed overload relay contacts B. a double pole knife switch C. normally-open overload relay contacts D. a single pole knife switch

Last Answer : Answer: A

Description : Power necessary to operate the horn relay shown in the illustration ____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through the relay's contacts D. also lights lamps 'R' and 'T'

Last Answer : Answer: A

Description : During the start-up of the circuit shown in the illustration, it is noted that the ends of component 'C' remain lighted but the tube does not illuminate. The cause of this problem is ____________. EL- ... ' is closed C. component 'C' is the wrong wattage D. component 'B' contacts are stuck closed

Last Answer : Answer: D

Description : To stop the electric motor shown in the illustration, the stop button is depressed, causing ____________. EL-0012 A. coil 'MS' to become de-energized B. contacts 'CR1' and 'MR4' to open C. contacts 'MR1', 'MR2', and 'MR3' to open D. contacts 'MS1', 'MS2', and 'MS3' to open

Last Answer : Answer: C

Description : When the motor shown in the illustration is running and the stop button is pushed, which of the following statements will hold true? EL-0010 A. Coil 'M' will now be energized. B. Coil 'CR' will now be energized. C. Contact 'M' will close as contact 'CR' opens. D. Contacts 'M' and 'CR' will open.

Last Answer : Answer: D

Description : As shown in the illustration, which of the operations listed will happen when the 'jog button' is pushed? EL-0010 A. Coil 'CR' closes the normally open 'CR' contacts. B. Coil 'M' opens contact 'M'. C. Coil 'M' closes contact 'M'. D. Contact 'M' remains open despite the jog button being pushed.

Last Answer : Answer: C

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : If the motor shown in the illustration will not start when 'Q' is depressed, which of the listed components should be checked FIRST? EL-0017 A. Fuses 'F-1' and 'F-2'. B. Operating coil 'C'. C. Contacts 'H-1', 'H-2', and 'H-3'. D. Contact 'H-4'.

Last Answer : Answer: A

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : Power necessary to operate the horn shown in the illustration _____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through a relay coil D. also lights lamps 'R' and 'T'

Last Answer : Answer: B

Description : The 'function generator' of the control circuit illustrated _______________. EL-0095 A. can be programmed to produce a non-linear output for a linear input depending on operating conditions B. is used for ... which or how many engines are needed for a required vessel speed D. all of the above

Last Answer : Answer: A

Description : What is the power rating safety factor for the light dimming rheostat shown in the illustration at '77H'? EL-0100 A. 1 B. 2 C. 3 D. 6

Last Answer : Answer: B

Description : Pin #8 of the astern valve position sensor shown in the illustration is connected _______________. EL-0099 A. to analog common B. in series with PCOM C. to (-) 50 volts D.C. D. to (+) 50 volts D.C.

Last Answer : Answer: A

Description : Pin #6 of the ahead valve position sensor as shown in the illustration is connected _______________. EL-0099 A. to (-) 50 volts D.C. B. in parallel with PCOM C. to (+) 50 volts D.C. D. to analog common

Last Answer : Answer: C

Description : If coils 'R1-R2-R3' at the receiver of figure 'B' shown in the illustration turned opposite of those in the transmitter, what corrective action should be taken to have both turn in the same direction? EL-0092 A ... is needed. C. Interchange leads 'R1' and 'R3'. D. Interchange leads 'R2' and 'R3'.

Last Answer : Answer: C