Which of the methods listed is used to start a AC generator turning? A. Residual magnetism remaining in the field poles. B. Residual magnetism remaining in the field coils. C. Residual magnetism remaining in the armature. D. Rotation by a mechanical prime mover.  

1 Answer

Answer :

Answer: D

Related questions

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : To increase the frequency of an operating AC generator, you should ____________. A. increase the field excitation B. decrease the field excitation C. increase the number of magnetic poles D. increase the speed of the prime mover

Last Answer : Answer: D

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : The prime mover of an AC two pole main propulsion generator drives the generator at 3600 RPM. If the main propulsion motor has 80 poles, what will be the propeller speed? A. 45 RPM B. 80 RPM C. 90 RPM D. 180 RPM

Last Answer : Answer: C

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed

Last Answer : Answer: D

Description : The voltage developed by an AC generator is controlled by varying the ____________. A. speed of the prime mover B. AC excitation to the field C. DC excitation to the field D. DC excitation of the voltage regulator

Last Answer : Answer: C

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : The power factor of an AC generator operating singularly is determined by the __________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: A

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : The frequency of an AC generator is adjusted by means of the ____________. A. main alternator field rheostat B. exciter field rheostat C. prime mover governor control D. equalizing reactor

Last Answer : Answer: C

Description : As load is added to an AC generator provided with constant field excitation, the prime mover slows down with the effect of ____________. A. lowering frequency and lowering generated ... C. increasing frequency and lowering generated voltage D. lowering frequency and increasing generated voltage

Last Answer : Answer: A

Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.

Last Answer : Answer: C

Description : One of the generator bearing shells is generally insulated from the end housing in order to prevent _____________. A. rapid brush wear B. residual magnetism leak off C. excessive field winding heat D. circulation of shaft currents

Last Answer : Answer: D

Description : Loss of or weak residual magnetism in an alternator or generator can be corrected for by _________________. A. running the rotor in the opposite direction for 5 minutes B. allowing the generator ... rheostat fully counterclockwise D. using a storage battery or battery charger to 'flash' the field

Last Answer : Answer: D

Description : Voltage failure of an AC generator may be caused by ____________. A. failure of the exciter generator B. a tripped bus circuit breaker C. high mica segments on the stator bus bar D. excessive prime mover speed

Last Answer : Answer: A

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the __________. A. manual position B. bus neutral position C. raise voltage position D. transfer position

Last Answer : Answer: A

Description : The output voltage of a 440 volt, 60 Hz AC generator is controlled by the ______________. A. load on the alternator B. load on the prime mover C. speed of the prime mover D. exciter output voltage

Last Answer : Answer: D

Description : A constant output voltage from an AC generator is maintained by the _____________. A. prime mover governor B. exciter generator C. voltage regulator D. reverse power relay

Last Answer : Answer: C

Description : Which of the following are the parts of a DC generator that convert the AC in the armature to DC in the external circuit. Are these parts the: w) field poles x) slip rings and the brushes y) commutator and the brushes z) armature and the core

Last Answer : ANSWER: Y -- COMMUTATOR AND THE BRUSHES

Description : Voltage build up in an isolated induction generator depends on A. Capacitor bank value B. Residual magnetism of the rotor iron C. Residual magnetism of the stator iron a) A, B b) A, B, C c) B d) A, C

Last Answer : Ans: A

Description : Insufficient brush pressure on a DC motor may cause _______. A. generator overload B. excess residual magnetism C. water vapor absorption D. sparking of the brushes

Last Answer : Answer: D

Description : The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the _____________. A. voltage regulators B. field rheostats C. reverse power relays D. prime mover governors

Last Answer : Answer: D

Description : If the connections for the field and the armature on a DC motor are reversed, _____________. A. the motor will run as a generator B. the motor will not run C. the direction of rotation will be the same D. the direction of rotation will be reversed

Last Answer : Answer: C

Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage

Last Answer : Answer: C

Description : The most common type of AC service generator found aboard ship is the stationary _____________. A. electromagnetic field, revolving armature type B. electromagnetic field, oscillatory armature type C. armature, oscillatory electromagnet field type D. armature, rotating electromagnetic field type

Last Answer : Answer: D

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an _____________. A. rotor B. stator C. exciter D. armature

Last Answer : Answer: C

Description : In the illustrated schematic diagram, which of the listed devices prevents the forward and reversing coils from being energized simultaneously? EL-0011 A. An 'either-or' interlock B. A mechanical interlock C. Blowout coils D. A stop button

Last Answer : Answer: A

Description : The amount of voltage induced in the windings of an AC generator depends mainly on _____________. A. the number of field poles energized B. the speed at which the stator windings rotate through the magnetic field C. the strength of the magnetic field D. all of the above

Last Answer : Answer: C

Description : On electrical generators one of the bearings is isolated from the bedplate. This insulating block should not be painted and must be kept clean to ___________. A. protect operating personnel from shock ... the prime mover as it warms up D. eliminate shaft currents to prevent damaging the bearings

Last Answer : Answer: D

Description : If the bearings of an electrical generator are failing more frequently than expected and the lubricating oil is sludging then you should ______________. A. check the connections to the output leads B. ... replace the bearing with a sealed roller type D. replace the thrust bearing of the prime mover

Last Answer : Answer: B

Description : In the illustration, the contacts between terminals 26 and 27 should be closed when _________. EL-0046 A. using one generator in isochronous mode only B. using two or more generators in ... through varying loads in parallel or single operation D. the circuit breaker is closed for that generator

Last Answer : Answer: C

Description : Which of the listed devices may be installed on a large diesel-electric alternating current propulsion generator? A. Temperature detector coils inserted in the stator slots for measuring stator temperature. B. ... . C. Electric space heaters to prevent condensation of moisture. D. All of the above.

Last Answer : Answer: D

Description : Which of the listed devices may be installed on a large turbo-electric alternating current propulsion generator? A. Temperature detector coils inserted in the stator slots for measuring stator temperature. B. A ... . C. Electric space heaters to prevent condensation of moisture. D. All of the above.

Last Answer : Answer: D

Description : The division of the reactive KVA load between paralleled AC generators is initiated by the ______________. A. prime mover governors B. voltage regulators C. phase balance relay D. proportioner

Last Answer : Answer: B

Description : Kilowatt load is divided between two AC generators operating in parallel by _____________. A. adjusting the governor controls B. varying the excitation voltage C. increasing both prime mover speeds simultaneously D. decreasing both prime mover speeds simultaneously

Last Answer : Answer: A

Description : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Description : In D.C. motor construction, the armature coils' ends are _______________. A. soldered to the commutator bar risers B. imbedded into core slots C. crimped together with brush pigtails D. spliced with the field windings

Last Answer : Answer: A

Description : In a compound-wound motor, a portion of the line current flows through the _____________. A. inertial poles B. stator C. shunt field coils D. frame

Last Answer : Answer: C

Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : If air gap readings for an electical generating machine have changed significantly from the last reading, you should check _________. A. the bearings B. insulation readings and machine cleanliness C. the prime mover thrust bearing D. the field coil bolts for the proper torque values

Last Answer : Answer: A

Description : Basic electrical motor action depends on _______________. A. a conductor rotated within a magnetic field B. a current carrying conductor placed in a magnetic field C. the relative force of the commutator and commutating poles D. the relative force of the armature and interpoles

Last Answer : Answer: B

Description : The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking

Last Answer : Answer: A

Description : If overloading a DC machine becomes necessary in an emergency, you should ____________. A. cool the machine with portable blowers and fans B. hold thermal overload relays open with blocks of ... the windings for cooling D. increase the residual magnetism value of windings to reduce eddy currents

Last Answer : Answer: A

Description : The insulation of electric generators during short idle periods should be _____________. A. allowed to cool slowly to ambient temperatures B. flashed with direct current to remove any residual ... using strip or space heaters D. relieved of all capacitive charge by grounding the conductors

Last Answer : Answer: C