The prime mover of an AC two pole main propulsion generator drives the generator at 3600 RPM. If the main propulsion motor has 80 poles, what will be the propeller speed?  A. 45 RPM B. 80 RPM C. 90 RPM D. 180 RPM

1 Answer

Answer :

Answer: C

Related questions

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : A four pole turbogenerator is used in conjunction with a 160 pole propulsion motor. If the generator is turning at 3,200 RPM, what is the current speed of the propeller? A. 40 RPM B. 60 RPM C. 80 RPM D. 100 RPM

Last Answer : Answer: C

Description : The propeller shaft speed in a turbo-electric, synchronous, propulsion drive motor is changed by varying the __________. A. turbine speed B. number of motor poles C. field strength of the generator D. field strength of the motor

Last Answer : Answer: A

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : To increase the frequency of an operating AC generator, you should ____________. A. increase the field excitation B. decrease the field excitation C. increase the number of magnetic poles D. increase the speed of the prime mover

Last Answer : Answer: D

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : Which of the methods listed is used to start a AC generator turning? A. Residual magnetism remaining in the field poles. B. Residual magnetism remaining in the field coils. C. Residual magnetism remaining in the armature. D. Rotation by a mechanical prime mover.

Last Answer : Answer: D

Description : The direction of propeller shaft rotation in a turbo-electric synchronous propulsion drive motor is changed by reversing the _____________. A. polarity of the propulsion motor B. polarity of the propulsion generator C. phase sequence of power to the motor D. phase sequence of power to the generator

Last Answer : Answer: C

Description : What will be the frequency of a three-phase, six pole, AC generator operating at 1800 revolutions per minute? A. 60 hertz B. 90 hertz C. 120 hertz D. 180 hertz

Last Answer : Answer: B

Description : If the synchronous speed of a 12 pole, polyphase, induction motor operating at 60 Hz were 600 RPM, how many poles will be required in a similar motor operating at the same frequency but having a synchronous speed of 900 RPM? A. 4 B. 6 C. 8 D. 18

Last Answer : Answer: C

Description : The synchronous speed for a 3 phase 6-pole induction motor is 1200 rpm. If the number of poles is now reduced to 4 with the frequency remaining constant, the rotor speed with a slip of 5% will be _________. (A) 1690 rpm (B) 1750 rpm (C) 1500 rpm (D) 1710 rpm

Last Answer : (D) 1710 rpm

Description : Voltage failure of an AC generator may be caused by ____________. A. failure of the exciter generator B. a tripped bus circuit breaker C. high mica segments on the stator bus bar D. excessive prime mover speed

Last Answer : Answer: A

Description : The voltage developed by an AC generator is controlled by varying the ____________. A. speed of the prime mover B. AC excitation to the field C. DC excitation to the field D. DC excitation of the voltage regulator

Last Answer : Answer: C

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : The power factor of an AC generator operating singularly is determined by the __________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: A

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : The output voltage of a 440 volt, 60 Hz AC generator is controlled by the ______________. A. load on the alternator B. load on the prime mover C. speed of the prime mover D. exciter output voltage

Last Answer : Answer: D

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : The frequency of an AC generator is adjusted by means of the ____________. A. main alternator field rheostat B. exciter field rheostat C. prime mover governor control D. equalizing reactor

Last Answer : Answer: C

Description : The most practical method of controlling the RPM of a step-speed AC motor is to _____________. A. change input voltage B. vary the number of poles C. vary power factor D. change the number of brushes

Last Answer : Answer: B

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the __________. A. manual position B. bus neutral position C. raise voltage position D. transfer position

Last Answer : Answer: A

Description : As load is added to an AC generator provided with constant field excitation, the prime mover slows down with the effect of ____________. A. lowering frequency and lowering generated ... C. increasing frequency and lowering generated voltage D. lowering frequency and increasing generated voltage

Last Answer : Answer: A

Description : A constant output voltage from an AC generator is maintained by the _____________. A. prime mover governor B. exciter generator C. voltage regulator D. reverse power relay

Last Answer : Answer: C

Description : In a diesel electric plant, raising the generator's field excitation will cause the DC propulsion motor to ________. A. increase in speed B. decrease in speed C. affect generator speed only D. affect main motor speed if done in conjunction with higher generator engine speeds

Last Answer : Answer: A

Description : What is the frequency of the output voltage of an alternator with four poles that is rotated at 3600 rpm?

Last Answer : 120 Hz.

Description : In the illustration, the contacts between terminals 26 and 27 should be closed when _________. EL-0046 A. using one generator in isochronous mode only B. using two or more generators in ... through varying loads in parallel or single operation D. the circuit breaker is closed for that generator

Last Answer : Answer: C

Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.

Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.

Description : The speed of a multi-speed, squirrel-cage, induction motor operating in a fixed frequency system can be changed by _____________. A. reconnecting stator windings for different numbers of poles B. ... sequence of the applied voltage D. reconnecting the stator so that no poles have the same polarity

Last Answer : Answer: A

Description : An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

Last Answer : 30 Hz As the frequency of the rotor is given by  F= N*P/120 so from the above equation the frequency of the rotor current can be easily calculated  i.e. 1800×8/120=30 Hence the required value of rotor frequency is 30 Hz

Description : On some diesel-electric ships, the DC propulsion motor will only attain half speed when the generator fields are fully excited. Speeds above this are obtained by _____________. A. rotating brush ... B. raising the generator engine speed C. lowering the generator engine speed D. decreasing excitation

Last Answer : Answer: B

Description : On a vessel with turbo-electric drive, which of the following conditions would indicate that the propulsion motor had dropped out of synchronization with the propulsion generator? A. Excessive ... Tripped main motor interlocks C. Overheated crosstie busses D. Closed contact in the field circuits

Last Answer : Answer: A

Description : The direction of rotation of a DC propulsion motor can be changed by reversing the _____________. A. brush holder position B. polarity of the field poles C. brush staggered order D. motor interpole connections

Last Answer : Answer: B

Description : An AC generator produces 60 Hz at 1800 RPM. If the generator speed is increased to 1830 RPM, the cycles will _____________. A. remain at 60 Hz B. increase to 61 Hz C. decrease to 59 Hz D. increase to 63 Hz

Last Answer : Answer: B

Description : A four-pole 60-hertz induction motor has a synchronous speed of 1800 RPM and a slip of 4 percent at full load. What will be its full load speed? A. 1728.0 RPM B. 1730.7 RPM C. 1800.0 RPM D. 1872.0 RPM

Last Answer : Answer: A

Description : A four-pole, 60 cycle, squirrel-cage motor has a full load speed of 1725 RPM. What will be the percent of slip at full load? A. 4.16 B. 4.34 C. 95.66 D. 95.84

Last Answer : Answer: A

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : A 4 pole lap wound dc shunt motor rotates at the speed of 1500 rpm, has a flux of 0.4 mWb and the total number of conductors are 1000. What is the value of emf? (A) 100 Volts. (B) 0.1 Volts. (C) 1 Volts. (D) 10 Volts.

Last Answer : Ans: D Given N = 1500 rpm, Φ = 0.4 mWb, Z = 1000, P = 4, & A= 4 Therefore, Eb = NΦPZ / 60 A = 1500 x 0.4 x 4 x 1000 x 10^-3 / 60 x 4 = 60/6 = 10 volts

Description : On electrical generators one of the bearings is isolated from the bedplate. This insulating block should not be painted and must be kept clean to ___________. A. protect operating personnel from shock ... the prime mover as it warms up D. eliminate shaft currents to prevent damaging the bearings

Last Answer : Answer: D

Description : If the bearings of an electrical generator are failing more frequently than expected and the lubricating oil is sludging then you should ______________. A. check the connections to the output leads B. ... replace the bearing with a sealed roller type D. replace the thrust bearing of the prime mover

Last Answer : Answer: B

Description : The amount of voltage induced in the windings of an AC generator depends mainly on _____________. A. the number of field poles energized B. the speed at which the stator windings rotate through the magnetic field C. the strength of the magnetic field D. all of the above

Last Answer : Answer: C

Description : The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the _____________. A. voltage regulators B. field rheostats C. reverse power relays D. prime mover governors

Last Answer : Answer: D

Description : Kilowatt load is divided between two AC generators operating in parallel by _____________. A. adjusting the governor controls B. varying the excitation voltage C. increasing both prime mover speeds simultaneously D. decreasing both prime mover speeds simultaneously

Last Answer : Answer: A

Description : Uneven wear of the commutator surface on a direct current propulsion motor can be caused by _____________. A. rapid change in load B. excessive operation at light load C. incorrect brush staggering D. unequal pole spacing

Last Answer : Answer: C

Description : The division of the reactive KVA load between paralleled AC generators is initiated by the ______________. A. prime mover governors B. voltage regulators C. phase balance relay D. proportioner

Last Answer : Answer: B

Description : A dc shunt generator has a speed of 800 rpm when delivering 20 A to the load at the terminal voltage of 220V. If the same machine is run as a motor it takes a line current of 20A from 220V supply. The speed of ... . (B) more than 800 rpm. (C) less than 800 rpm. (D) both higher or lower than 800 rpm.

Last Answer : (C) less than 800 rpm.

Description : As shown in the illustration, the motor generator(M-G) set's three-phase motor drives the ______________. EL-0101 A. motor and the generator B. motor and the exciter C. generator and the exciter D. main field and the interpole field

Last Answer : Answer: C

Description : As shown in the illustration, the M-G set's three-phase motor drives the ______________. EL-0101 A. motor and the generator B. motor and the exciter C. generator and the exciter D. main field and the interpole field

Last Answer : Answer: C