Which of the following actions must be carried out prior to closing the alternator circuit breaker according to the graph shown in the illustration? EL-0002 A. Increase the alternator voltage. B. Decrease the line voltage. C. Increase the line voltage. D. Decrease the line frequency.

1 Answer

Answer :

Answer: A

Related questions

Description : As shown in the illustration, which of the listed actions of the synchroscope pointer is occurring? EL-0002 A. Revolving slowly in the slow direction. B. Revolving rapidly in the slow direction. C. ... stationary at the 12 o'clock position since the leading edges of the A phases are in phase.

Last Answer : Answer: C

Description : An alternator is being paralleled with one on the line. At the INSTANT the circuit breaker is closed, the frequency of the incoming alternator will normally _____________. A. increase B. not change C. decrease D. be exactly 60 hertz

Last Answer : Answer: C

Description : When paralleling two AC generators, the frequency (cycles) of the incoming generator, just prior to closing the circuit breaker, should be _____________. A. slightly less than the frequency of the generator on ... C. slightly more than the frequency of the generator on the line D. all of the above

Last Answer : Answer: C

Description : When paralleling two AC generators, the frequency of the machine coming online, immediately prior to closing its breaker, should be ____________. A. slightly less than the oncoming generator frequency B. the ... bus frequency C. slightly greater than the bus frequency D. the same as the bus voltage

Last Answer : Answer: C

Description : When paralleling two AC generators, the frequency of the incoming machine immediately prior to closing its breaker should be ____________. A. controlled by placing the governor switch in the automatic ... regulator C. slightly greater than the bus frequency D. slightly less than the bus frequency

Last Answer : Answer: C

Description : You are attempting to parallel two AC generators and the synchroscope pointer stops at a position other than 0° prior to closing the circuit breaker. This indicates ___________. A. the frequency of ... be closed after breaker has been reset D. there is an existing cross current between generators

Last Answer : Answer: A

Description : Prior to closing the breaker when paralleling two AC generators, the recommended practice is to have the frequency of the incoming machine _____________. A. slightly less than the line frequency B. the same as the line frequency C. slightly greater than the line frequency D. all of the above

Last Answer : Answer: C

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : As shown in the illustration, 'B' is a ____________. EL-0058 A. single-pole, double-throw switch B. double-pole, single-throw switch C. double-pole, double-throw switch D. circuit breaker

Last Answer : Answer: C

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : When changing out component 'B' of the circuit shown in the illustration, it is important to know that ____________. EL-0081 A. it is polarity sensitive and must be inserted as indicated on its ... provide the capacitor's initial charge D. it must match the circuit voltage and component 'C' wattage

Last Answer : Answer: D

Description : When replacing component 'B' of the circuit shown in the illustration, it is important to know that ____________. EL-0081 A. it is polarity sensitive and must be inserted as indicated on its ... provide the capacitor's initial charge D. it must match the circuit voltage and component 'C' wattage

Last Answer : Answer: D

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : If the line voltage to the controller shown in the illustration is 440 volts, what is applied across the control circuit? EL-0080 A. 110 volts B. 220 volts C. 440 volts D. 660 volts

Last Answer : Answer: C

Description : Which of the following actions must be carried out before a voltage tester can be used to test the three line fuses to a three-phase motor? A. The fuses must be removed from the circuit. B. The ... disconnected and tagged. D. Nothing need be done as long as the motor is running under a light load.

Last Answer : Answer: B

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : An alternator will fail to produce line voltage as a result of _____________. A. a closed circuit breaker B. oxidized slip rings C. improperly staggered brushes D. exciter generator failure

Last Answer : Answer: D

Description : In order to decrease the resistance of the 50K pot located at '21Q/R' shown in the illustration, the wiper of the actual component must be moved ____________. EL-0099 A. to the left B. to the right C. clockwise D. counterclockwise

Last Answer : Answer: D

Description : RC time constant characteristics, as shown in the illustration, are important in _____________. EL-0086 A. bridge rectifiers for alternator excitation B. timing and pulse shaping circuits C. transistor power amplifier biasing D. motor controller overload protection

Last Answer : Answer: B

Description : Which of the following statements describes what will occur if the motor shown in the illustration is required to carry 150% of full load? EL-0056 A. The primary counter emf will be increased. B. ... slip will decrease. D. The slip value, stator current curve, and torque curve will all coincide.

Last Answer : Answer: B

Description : Which of the synchroscope illustrations depicts the appropriate direction of rotation and position for closing the circuit breaker when paralleling AC generators? EL-0053 A. A B. B C. C D. D

Last Answer : Answer: D

Description : Assuming a standard 60 Hz. input to the circuit shown in the illustration, the ripple frequency would be ____________. EL-0085 A. 30 Hz B. 60 Hz C. 90 Hz D. 120 Hz

Last Answer : Answer: D

Description : If a frequency of 2.5 kHz were measured at the output of 'FF-C' in the circuit shown in the illustration, what would be the clock frequency? EL-0087 A. 0.8 kHz B. 2.5 kHz C. 7.5 kHz D. 20 kHz

Last Answer : Answer: D

Description : If a frequency of 16.8 kHz were measured at the output of 'FF-C' of the circuit shown in the illustration, the clock frequency would be _____________. EL-0087 A. 8.4 kHz B. 50.4 kHz C. 134.4 kHz D. 1680.0 kHz

Last Answer : Answer: C

Description : If the clock frequency to the circuit shown in the illustration were 100 kHz, what would be indicated at the output of 'FF-C'? EL-0087 A. 10.1 kHz B. 12.5 kHz C. 805 kHz D. 1010 kHz

Last Answer : Answer: B

Description : If the clock frequency to the circuit shown in the illustration were 2 kHz, what would be indicated at the output of 'FF-C'? EL-0087 A. 250 Hz B. 666 Hz C. 6 kHz D. 16 kHz

Last Answer : Answer: A

Description : If a voltage tester is being used to check for defective fuses in the circuit, shown in the illustration, which of the readings will indicate that fuse #2 is open? EL-0062 A. C-B full voltage B. A-D full voltage C. A-D no voltage D. C-B no voltage

Last Answer : Answer: C

Description : The wiring diagram for the motor starting circuit shown in the illustration indicates ______________. EL-0007 A. resistance starting B. reduced voltage starting C. low voltage protection D. low voltage release

Last Answer : Answer: C

Description : As shown in the illustration if the applied voltage is 12 VDC, the resistance of R1 is 10 ohms, and R2 is 10 ohms what is the total power consumed by the circuit? EL-0036 A. 3.6 watts B. 72 watts C. 7.2 watts D. 36 watts

Last Answer : Answer: C

Description : As shown in the illustration if the applied voltage is 12 VDC, the resistance of R1 is 10 ohms, and R2 is 10 ohms what is the total current in the circuit? EL-0036 A. 0.6 amp B. 0.833 amp C. 1.2 amps D. 2.4 amps

Last Answer : Answer: A

Description : As shown in the illustration if the applied voltage is 12 VDC, the resistance of R1 is 110 ohms, and R2 is 10 kohms what is the total power consumed by the circuit? EL-0036 A. 3.6 watts B. 72 watts C. .0011286 watts D. .014243 watts

Last Answer : Answer: D

Description : What would be the voltage drop across the series resistor of the circuit shown in the illustration if the source is 30 volts, the resistance of R1 is 10 ohms, R2 is 10 ohms and R3 is 10 ohms? EL-0032 A. 5 volts B. 10 volts C. 20 volts D. 30 volts

Last Answer : Answer: C

Description : What would be the voltage drop across the parallel branches of the circuit shown in the illustration if the source is 30 volts the resistance for R1 is 10 ohms, R2 is 10 ohms and R3 is 10 ohms? EL-0032 A. 5 volts B. 10 volts C. 20 volts D. 30 volts

Last Answer : Answer: B

Description : In the illustration, the voltage applied to the circut is 12 VDC, the resistance for R1 is 10 ohms, and R2 is 10 ohms. What is the power consumed in 'R1' of the circuit shown in the illustration? EL-0036 A. 0.6 watts B. 3.6 watts C. 7.2 watts D. 120 watts

Last Answer : Answer: B

Description : The voltage at the reference electrode of the circuit shown in the illustration is applied to the input of a/an ______________. EL-0090 A. class A detector whose output drives an ... drives an 2-stage isolation transformer D. magnetic amplifier whose output controls a saturable reactor

Last Answer : Answer: D

Description : The component labeled 'CR1' in the circuit shown in the illustration __________________. EL-0085 A. varies its anode/cathode polarity depending on 'RL' current B. rectifies the varying voltage from the ... reactance to smooth ripple D. establishes a constant reference voltage for the base of 'Q1'

Last Answer : Answer: D

Description : When the circuit shown in the illustration is operating correctly, the voltage at the reference electrode will be kept in the optimum range of ____________. EL-0090 A. 0.01 - 0.05 volt B. 0.80 - 0.85 volt C. 35 - 60 volts D. 100 - 115 volts

Last Answer : Answer: B

Description : Considering the function of the circuit shown in the illustration, what is the purpose of supplying the thrust lever potentiometers with both (+) and (-) 15 volts? EL-0095 A. To select which ... alternate voltage supply if the other fails. D. So as to automatically select the position of Relay #

Last Answer : Answer: B

Description : Section II of the circuit shown in the illustration is the ____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: C

Description : Section IV of the circuit shown in the illustration is the _____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: A

Description : What is the polarity of voltage at point 'Z' in the circuit shown in the illustration? EL-0085 A. It will always be positive. B. It will always be negative. C. It depends on the instantaneous polarity at point 'W'. D. It cannot be determined without a voltmeter.

Last Answer : Answer: A

Description : Section III of the circuit shown in the illustration is a _____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: B

Description : What is indicated by gradual blackening at the ends of component 'C' shown in the illustration? EL-0081 A. The unit is in danger of exploding. B. The tube is nearing the end of its useful life. C. The circuit voltage is too high. D. The circuit current is too high.

Last Answer : Answer: B

Description : The graph shown in the illustration represents the speed droop curves of two equal capacity alternators about to be paralleled. When paralleled, the greater portion of the total load above 60% for each unit will be picked up ... unit 'A' B. by unit 'B' C. equally by each unit D. none of the above

Last Answer : Answer: A

Description : In the illustration, the signal from the device connected to terminals 18 and 19 is __________. EL-0046 A. prime mover speed feedback B. loss of control alarm when comparing with the input signal ... slip between the prime mover and the alternator D. to shut down the prime mover if overspeeding

Last Answer : Answer: A