How do connect a wye connection for 12 leads out motor?

1 Answer

Answer :

Normally there are six terminals (two terminals per winding in 3phase system) for a motor. If you find 12 terminals, you need toread the motor name details or specifications to get more info. Themotor could be with two different sets of winding (double speedmotor)

Related questions

Description : Which of the following statements about a three-phase wye connection is correct? A. The line current is 1.73 times the phase current. B. The phase current is 1.73 times the line current. C. The line voltage is 1.73 times the phase voltage. D. The phase voltage is 1.73 times the line voltage.

Last Answer : Answer: C

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : How do you wire a star wye motor?

Last Answer : This is better explained through a wiring diagram. AC 3 phasemotor has three windings. Each winding has two terminals. Lets usdenote each winding as follows. Winding 1 - A1 and A2, Winding 2 -B1 ... to refer to motor name plate, its wiring diagram. You needto also check the direction of rotation.

Description : One important difference between wye-connected and delta-connected generators is that delta connections have ____________. A. line voltages equal to the vector sum of the phase voltages B. phase voltages 90° ... C. line current equal to the phase current D. line voltage equal to the phase voltage

Last Answer : Answer: D

Description : The electrical schematic illustrated in figure A, depicts a/an _____________. EL-0059 A. autotransformer B. Delta Wye transformer C. primary EMF generator D. potential transformer

Last Answer : Answer: D

Description : If you obtain a low resistance reading with a megohmmeter connected between terminals 'A' and 'C' of the three-phase, wye-connected winding shown in the illustration, there is __________. EL-0074 A. no open circuit ... 'B' C. an open circuit between 'A' and 'C' D. an open circuit in both windings

Last Answer : Answer: A

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase delta-wye arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: C

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase wye-delta arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: D

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase wye-wye arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: B

Description : Where WYE body globe valve is used?

Last Answer : Answer: In line ports with stem emerging at 45 degree, for erosive fluids due to smoother flow pattern.

Description : Wye (Star) to Delta Conversion

Last Answer : Wye (Star) to Delta Conversion

Description : Delta to Wye Conversion

Last Answer : Delta to Wye Conversion

Description : Wye and delta conversion formula

Last Answer : Wye and delta conversion formula

Description : Wye Delta Transformation

Last Answer : Wye Delta Transformation 1 : https://youtu.be/mPKeczDWZCo Wye Delta Transformation 2 : https://youtu.be/k80VbHI-wwg Wye Delta Transformation 3 : https://youtu.be/6cnwj15uw5M Wye Delta Transformation ... 8 : https://youtu.be/knRb5UW1404 Wye Delta Transformation 9 : https://youtu.be/JBwHKBJ08WM

Description : In order to determine whether or not 'fuse 2' shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: B

Description : In order to determine whether or not 'Fuse 1', shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: C

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : The speed of a synchronous motor is varied by _____________. A. interchanging any two of the three live leads B. changing the voltage of the system C. changing the input frequency D. increasing the field excitation

Last Answer : Answer: C

Description : To check the three line fuses of a three-phase system consisting of a three-phase motor, you must _____________. A. place the starter in the 'stop' position B. make sure the motor is operating at full ... leads across the 'hot' ends of the fuses D. place the leads across the bottom ends of the fuses

Last Answer : Answer: A

Description : The leads from a megohmmeter are attached to the leads of an AC motor field coil. A reading of infinity is obtained indicating a/an ____________. A. open field coil B. shorted field coil C. grounded field coil D. shunted field coil

Last Answer : Answer: A

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : The reversal of an AC, three-phase, induction motor is accomplished by ______________. A. changing all three motor leads B. reversing the position of the slip rings C. interchanging any two of the three motor leads D. interchanging any two brushes

Last Answer : Answer: C

Description : The rotation of a three-phase induction motor can be reversed by _____________. A. interchanging any two of the three line leads to the stator B. disconnecting one of the three line leads to the ... the shunt field coil leads D. permanently disconnecting any two of the three line leads to the stator

Last Answer : Answer: A

Description : Reversing any two of the three rotor leads on a wound-rotor induction motor will _____________. A. increase motor performance B. decrease motor performance C. reverse the motor rotation D. have no effect on the direction of rotation or motor performance

Last Answer : Answer: D

Description : Which of the following methods should be used to test for an 'open' coil in an AC motor stator? A. Test with an ohmmeter, one test lead on the shaft, and the other test lead to the stator leads ... an open coil. D. Use a growler, listening for noise and vibration to increase when over an open coil.

Last Answer : Answer: B

Description : Electrical leads and insulation on a motor should be painted with ____________. A. heat-resisting acrylic B. heat-resisting aluminum C. insulating varnish D. insulating white lead

Last Answer : Answer: C

Description : A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be:

Last Answer : A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be: (2-s)

Description : How can I make Windows Vista connect to a broadband connection instead of the users old dial-up connection?

Last Answer : First of all do they have an ethernet network card? If not one needs to be installed. If one is than Open control panel > Hardware and Sound > Device manager > Network adapters > The network card on ... lol. *edited in hardware and sound. XP doesn't have the silly Vista view of the control panel.

Description : A ………….. is a temporary connection that uses the Public Switched Telephone Network (PSTN) to connect to the Internet. -Technology

Last Answer : dial-up connection

Description : What is the use of ADSL (direct) and wireless connection used to connect to the internet and supply an example?

Last Answer : ADSL is a method of multiplexing a broadband internet connection over an existing landline telephone wire that is still being used for voice band telephone.Wireless (usually Wi-Fi) is a method of connecting computers ... an ADSL modem, a SDSL modem, a cable modem, a satellite modem, etc. if desired.

Description : How to connect computer to a remote desktop connection?

Last Answer : On your computer, you will click on Start, Programs, Accessories, Remote Desktop Connection. In the computer box, you need to enter an IP number (which your office IT person will give you). Enter your login and password. Click Connect.

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : An electrical connection between the wiring of an electric motor and its metal frame is known as a/an _____________. A. eddy current B. ground C. impedance D. flux leakage

Last Answer : Answer: B

Description : Motor controllers are seldom troubled with grounds because _____________. A. the auxiliary contacts have a high resistance connection B. the contactors and relays are mounted on a nonconducting panel ... individual series-connected units D. there are separate switches for the motor and the control

Last Answer : Answer: B

Description : Which of the illustrations listed below is representative of a motor controller's 'wiring' or 'connection' diagram? Book A. EL-0023 B. EL-0024 C. EL-0037 D. EL-0058

Last Answer : Answer: A

Description : A ground can be defined as an electrical connection between the wiring of a motor and its ____________. A. shunt field B. circuit breaker C. metal framework D. interpole

Last Answer : Answer: C

Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Description : How you will connect start and stop push button to control the motor from two different places?

Last Answer : Start push button should be connected in parallel and stop push button in series in the circuit.  

Description : Will there be infinite energy when we connect electric motor and electric generator to a cycle?

Last Answer : No, because they both don't have 100% efficiency practically, so there will be losses.

Description : The study of occupational information should be Options: A) Postponed until the pupil is ready to choose a vocation B) Introduced in connection with a programme of self-appraisal C) Handled only by the school's occupation counsellor D) Made a regular 10th and 12 th grade subject

Last Answer : B) Introduced in connection with a programme of self-appraisal