The leads from a megohmmeter are attached to the leads of an AC motor field coil. A reading of infinity is obtained indicating a/an ____________. A. open field coil B. shorted field coil C. grounded field coil D. shunted field coil

1 Answer

Answer :

Answer: A

Related questions

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : The final step in testing a circuit for a ground involves the use of a megohmmeter. A grounded switch or cable will be indicated by a megohmmeter reading of ____________. A. 'zero' B. infinity C. steady in the high range D. unsteady in the low range

Last Answer : Answer: A

Description : When using a megohmmeter to determine which shunt field coil is grounded in a DC machine, you must ____________. A. insulate the field frame from the ship's hull B. disconnect each shunt ... C. use a motor driven high capacity megohmmeter D. remove all main line lead connections before testing

Last Answer : Answer: B

Description : Aboard ship, a grounded field coil in an AC motor can be determined by using a _________________. A. portable growler B. galvanometer C. visual inspection D. megohmmeter

Last Answer : Answer: D

Description : When troubleshooting AC motors, a portable growler can be used for locating ____________. A. open field coils B. grounded field coils C. grounded stator coils D. shorted stator coils

Last Answer : Answer: D

Description : A megohmmeter is connected to each end of an individual motor winding. A low ohm reading indicates ____________. A. an open coil B. a loose coil C. good continuity D. a dirty coil

Last Answer : Answer: C

Description : A megohmmeter can be used to test for _____________. A. an open field coil B. a shorted field pole C. undercut mica D. reversed polarity

Last Answer : Answer: A

Description : When a megohmmeter is being used on a alternating current machine, the meter pointer will dip toward 'zero' and then gradually rise to the true resistance value if the motor insulation is _____________. A. grounded B. good C. shorted D. dirty

Last Answer : Answer: B

Description : A grounded switch or cable will be indicated by a megohmmeter reading of _____________. A. infinity B. 'zero' C. being unsteady in the high range D. being unsteady in the low range

Last Answer : Answer: B

Description : Which of the instruments listed could be use to locate a grounded field coil in a synchronous motor? A. Ammeter B. Voltmeter C. Megohmmeter D. Frequency meter

Last Answer : Answer: C

Description : Which of the listed instruments can be best used to locate a grounded field coil in a synchronous motor? A. Frequency meter B. Megohmmeter C. Voltmeter D. Multimeter

Last Answer : Answer: B

Description : Prior to using an analog type ohmmeter, the leads are purposely shorted together. Which of the following actions should be taken if, when adjusting to 'zero' ohms, the indicating needle can not be ... be added to each final reading. D. The test reading should be subtracted from each final reading.

Last Answer : Answer: B

Description : While testing a semi-conductor diode with an ohmmeter, both the forward and reverse readings are almost in the infinity range. This would indicate that the unit is _____________. A. good B. open C. grounded D. shorted

Last Answer : Answer: B

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : A megohmmeter can be used to test for ____________. A. an open field coil B. synchronous speed C. undercut mica D. reversed polarity

Last Answer : Answer: A

Description : A short in the shunt field of a DC motor is best located by _____________. A. visual inspection of the commutator B. applying AC voltage to each field coil and measuring the voltage drop across ... using a growler and hacksaw blade D. isolating each coil from the others and using a megohmmeter

Last Answer : Answer: B

Description : When using the test set-up shown in the illustration, the lighted lamp indicates the winding is ____________. EL-0027 A. grounded B. good C. open D. shorted

Last Answer : Answer: A

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : A capacitor is to be tested with a megohmmeter. If the meter is connected to a shorted capacitor, the meter pointer should _____________. A. immediately swing to the maximum resistance value ... and gradually decrease D. swing to zero then gradually increase with slight pointer movements down scale

Last Answer : Answer: B

Description : A capacitor can be tested using a megohmmeter or an ohmmeter. If the meter is connected to a shorted capacitor, the meter pointer should _____________. A. immediately swing to the maximum resistance ... deflect to and remain at zero D. immediately swing to a high reading and then gradually decrease

Last Answer : Answer: C

Description : When a switch capacity is full, calls coming into that switch are said to be____. (A) open (B) shorted (C) blocked (D) shunted

Last Answer : (C) blocked

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test, because the ___________. A. static charge of the machine ... number of leakage paths C. insulation may be damaged D. insulation may be covered with moisture

Last Answer : Answer: A

Description : Which of the following methods should be used to test for an 'open' coil in an AC motor stator? A. Test with an ohmmeter, one test lead on the shaft, and the other test lead to the stator leads ... an open coil. D. Use a growler, listening for noise and vibration to increase when over an open coil.

Last Answer : Answer: B

Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage

Last Answer : Answer: C

Description : A testing device called a 'growler' is being used to locate a shorted coil in the stator of an AC electrical machine. When the 'feeler' is moved over a slot containing the shorted coil _____________. ... . the meter needle will be deflected to zero D. the meter needle will be deflected to full-scale

Last Answer : Answer: A

Description : One diode of a full-wave rectifier has burned out in a shorted condition. Therefore, the output will be ____________. A. zero B. a rectified half-wave C. a rectified full-wave D. equal to the AC input

Last Answer : Answer: D

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the main winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the run winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica

Last Answer : Answer: A

Description : When a megohmmeter is used to test the insulation of a large motor, the initial dip of the pointer toward 'zero' is caused by ____________. A. good insulation B. the capacitance of the ... of the current along the surface of dirty insulation D. the dielectric-absorption effect of the insulation

Last Answer : Answer: B

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointer to mid-scale B. short the test leads and calibrate the meter reading to 'zero' C. change the meter's batteries D. center the meter's pointer at infinity

Last Answer : Answer: B

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : The rotation of a three-phase induction motor can be reversed by _____________. A. interchanging any two of the three line leads to the stator B. disconnecting one of the three line leads to the ... the shunt field coil leads D. permanently disconnecting any two of the three line leads to the stator

Last Answer : Answer: A

Description : In which of the situations listed will a megohmmeter give the most accurate readings? A. While the machine is in operation. B. While the machine is discharging static electricity. C. Immediately prior to ... machine. D. When the machine has been shut down and grounded for a period of 15 minutes.

Last Answer : Answer: D

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test as the ______________. A. insulation may be damaged ... number of leakage paths D. larger machines may acquire a charge of static electricity during operation

Last Answer : Answer: D

Description : The electrical device shown in the illustration is a/an _____________. EL-0077 A. operating coil B. indicating lamp C. motor armature D. potentiometer

Last Answer : Answer: D

Description : While paralleling two (2) AC generators using synchronizing lamps only, both lamps will go dark when the generators are ____________. A. running at the same speed B. grounded C. of the same polarity D. in phase

Last Answer : Answer: D

Description : If all three ground-detection lamps continue to burn at equal intensity after the test button is depressed and released, which of the listed conditions is indicated? A. No grounds exist B. All three phases are grounded C. The test switch is faulty D. The current transformers are shorted out

Last Answer : Answer: A

Description : On a switchboard, if all three ground detection lamps remain burning at half intensity when the test button is depressed, which of the listed conditions is indicated? A. No grounds exist. B. All three phases are grounded. C. The test switch is grounded. D. The current transformers are shorted.

Last Answer : Answer: A

Description : Which of the following statements regarding the use of a current measuring instrument is correct? A. It must be connected in series with the circuit. B. You should always start with the lowest range ... of polarity. D. An external shunt is generally utilized where current is less than 10 amperes.

Last Answer : Answer: A

Description : If you obtain a low resistance reading with a megohmmeter connected between terminals 'A' and 'C' of the three-phase, wye-connected winding shown in the illustration, there is __________. EL-0074 A. no open circuit ... 'B' C. an open circuit between 'A' and 'C' D. an open circuit in both windings

Last Answer : Answer: A

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : To stop the electric motor shown in the illustration, the stop button is depressed, causing ____________. EL-0012 A. coil 'MS' to become de-energized B. contacts 'CR1' and 'MR4' to open C. contacts 'MR1', 'MR2', and 'MR3' to open D. contacts 'MS1', 'MS2', and 'MS3' to open

Last Answer : Answer: C

Description : In the illustrated ground detection system with a ground on phase A, if the switch is opened __________. EL-0009 A. lamp A will dim or go out depending on the severity of the ground B. all three ... lamp A will be brighter D. lamp A will start flickering if the ground is in an AC induction motor

Last Answer : Answer: B

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : An open occurring within the field rheostat of an AC generator can be detected by short circuiting its terminals and observing a ____________. A. negative deflection of the wattmeter pointer B. ... of the wattmeter pointer C. buildup of alternator voltage D. low, but constant alternator voltage

Last Answer : Answer: C