The generation voltage is usually
(A) between 11 KV and 33 KV. (B) between 132 KV and 400 KV.
 (C) between 400 KV and 700 KV. (D) None of the above.

1 Answer

Answer :

(A) between 11 KV and 33 KV.

Related questions

Description : The operating voltage of extra high tension cables is upto (a) 6.6 kV (b) 11 kV (c) 33 kV (d) 66 kV (e) 132 kV

Last Answer : (d) 66 kV

Description : For transmission of power over a distance of 200 km, the transmission voltage should be (a) 132 kV (b) 66 kV (c) 33 kV (d) 11 kV

Last Answer : (a) 132 kV

Description : Pressure cables are generally not used beyond (a) 11 kV (b) 33 kV (c) 66 kV (d) 132 kV

Last Answer : (c) 66 kV

Description : Overhead system can be designed for operation up to (a) 11 kV (b) 33 kV (c) 66 kV (d) 400 kV

Last Answer : (c) 66 kV

Description : Overhead system can be designed for operation up to (a) 11 kV (b) 33 kV (c) 66 kV (d) 400 kV

Last Answer : (c) 66 kV

Description : The voltage at the two ends of a transmission line are 132 KV and its reactance is 40 ohm. The Capacity of the line is (A) 435.6 MW (B) 217.8 MW (C) 251.5 MW (D) 500 MW

Last Answer : (A) 435.6 MW

Description : The operating voltage of supertension cables is up to (a) 3.3 kV (b) 6.6 kV (c) 11 kV (d) 33 kV

Last Answer : (d) 33 kV

Description : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is (A) 0.85 Ω (B) 3.63 Ω (C) 36.3 Ω (D) 252 Ω

Last Answer : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is 3.63 Ω

Description : cables are used for 132 kV lines. (a) High tension (b) Super tension (c) Extra high tension (d) Extra super voltage

Last Answer : (d) Extra super voltage

Description : If voltage at the two ends of a transmission line is 132 kV and its reactance is 40 Ohms, the capacity of the line will be: (A) 435.6 MW (B) 217.8 MW(C) 251.5 MW (D) 500 MW

Last Answer : If voltage at the two ends of a transmission line is 132 kV and its reactance is 40 Ohms, the capacity of the line will be: 435.6 MW

Description : A 100 km transmission line is designed for a nominal voltage of 132 kV and consists of one conductor per phase. The line reactance is 0.726 ohm/km. The static transmission capacity of the line, in MW, would be   (a) 240 (b) 132 (c) 416 (d) 720

Last Answer : A 100 km transmission line is designed for a nominal voltage of 132 kV and consists of one conductor per phase. The line reactance is 0.726 ohm/km. The static transmission capacity of the line, in MW, would be 240 

Description : If a voltage of 132 VDC is applied to the illustrated circuit where the resistance is 12 ohms, then current will be ___________. EL-0018 A. 0.090 amps B. 1.090 amps C. 11 amps D. 144 milliamps

Last Answer : Answer: C

Description : Which of the following is usually not the generating voltage ? (a) 6.6 kV (b) 8.8 kV (c) 11 kV (d) 13.2 kV

Last Answer : (b) 8.8 kV

Description : If we give 2334 A, 540V on Primary side of 1.125 MVA step up transformer, then what will be the Secondary Current, If Secondary Voltage=11 KV?

Last Answer : A. As we know the Voltage & current relation for transformer-V1/V2 = I2/I1 We Know, VI= 540 V; V2=11KV or 11000 V; I1= 2334 Amps. By putting these value on Relation540/11000= I2/2334 So,I2 = 114.5 Amps

Description : If we give 2334 A, 540V on Primary side of 1.125 MVA step up transformer, then what will be the Secondary Current, If Secondary Voltage=11 KV?

Last Answer :  As we know the Voltage & current relation for transformer-V1/V2 = I2/I1 We Know, VI= 540 V; V2=11KV or 11000 V; I1= 2334 Amps. By putting these value on Relation540/11000= I2/2334 So,I2 = 114.5 Amps

Description : For cost and safety, the outdoor substations are installed for voltages above (a) 11 kV (b) 33 kV (c) 60kV (d) 110kV

Last Answer : (b) 33 kV

Description : The underground system cannot be operated above (a) 440 V (b) 11 kV (c) 33 kV (d) 66 kV

Last Answer : (d) 66 kV

Description : Pin type insulators are generally not used for voltages beyond (a) 1 kV (b) 11 kV (c) 22 kV (d) 33 kV

Last Answer : (d) 33 kV

Description : The underground system cannot be operated above (a) 440 V (b) 11 kV (c) 33 kV (d) 66 kV

Last Answer : (d) 66 kV

Description : How many insulator disc used for 33 kV transmission voltage line?

Last Answer : 5,As 33kv is Vrms

Description : Why resistance grounding preferred for less than 33 kV and more than 415 V?

Last Answer : a) To limit the earth fault current for equipment safety else, high short ckt forces dislocate in windings/bus bars etc, b) Over voltage due to arcing ground reduced c) Permits earth fault protection (not possible in ungrounded system)

Description : Why neutrals are solid grounded above 33 kV? 

Last Answer : a) Less transient over voltage due to arcing grounds. b) Voltage of phases are limited to phase to ground voltage. (No neutral shifting) c) Allows graded insulation of transformer (low cost) d) Fast E/F protection. 

Description : Large industrial consumers are supplied electrical energy at (a) 400 V (b) 11 kV (c) 66 kV (d) 400 kV

Last Answer : (c) 66 kV

Description : The magnetizing reactance of a 4 kV/ 400 V, 50 Hz single-phase transformer on low voltage side is 35 Ω. The magnetizing reactance on the high voltage side is (A) 0.35 Ω (B) 3.5 Ω (C) 350 Ω (D) 3500 Ω

Last Answer : 3500

Description : High tension cables are generally used up to (a) 11kV (b) 33kV (c) 66 kV (d) 132 kV

Last Answer : (a) 11kV

Description : The dielectric strength of transformer oil should be (A) 100 V. (B) 5 KV. (C) 30 KV. (D) 132 KV.

Last Answer : (C) 30 KV.

Description : Why 6.6 kV transformer is resistance grounded by 10 ohms and current limited to 400 A?

Last Answer : a) To reduce burning and melting in faulted switchgear or machine. b) To reduce mechanical stresses in equipment. c) To reduce the electrical hazards by stray ground fault currents in the ground ... screen in 6.6 kV XLPE (cross-linked polyethylene). Therefore the cost of the cable decreases. 

Description : When a voltage of 132 VDC is applied to the illustrated circuit with a resistance of 237 ohms the current will be ________. EL-0018 A. 1.236 amps B. 2.048 amps C. 0.557 amps D. 4.200 amps

Last Answer : Answer: C

Description : When a voltage of 132 VDC is applied to the illustrated circuit with a resistance of 470 ohms the current will be ________. EL-0018 A. 0.280 amps B. 3.560 amps C. 602 milliamps D. 1.673 amps

Last Answer : Answer: A

Description : When a voltage of 132 VDC is applied to the illustrated circuit with a resistance of 10,230 ohms the current will be ________. EL-0018 A. 0.012 amps B. 77.5 milliamps C. 10,362 amps D. 0.792 amps

Last Answer : Answer: A

Description : When a voltage of 132 VDC is applied to the illustrated circuit with a resistance of 110 ohms the current will be ________. EL-0018 A. 0.833 amps B. 1.2 amps C. 2.2 amps D. 242 milliamps

Last Answer : Answer: B

Description : When a voltage of 132 VDC is applied to the illustrated circuit with a resistance of 32 ohms the current will be ________. EL-0018 A. 0.242 amps B. 4.125 amps C. 7.757 amps D. 1.64 amps

Last Answer : Answer: B

Description : How many times do 33 go into 132?

Last Answer : 4

Description : Why the earthing transformer primary voltage is 16.5 kV rated in main generator even though actual voltage during the E/F is root 3 times less?

Last Answer : The transformer should not saturate during E/F otherwise it will cause ferroresonance with the GT winding capacitance. Dangerous O/V and neutral shifting will occur. During loss of load or field ... saturation. Saturation can also occur due to point on wave of application causing flux doubling. 

Description : What is the minimum voltage required for starting of 6.6 kV motors?

Last Answer : Minimum 80% of rated voltage.

Description : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is  (A) 1200 A (B) 3600 A (C) 35 kA (D) 104.8 kA

Last Answer : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is 35 kA 

Description : A 3-phase circuit breaker is rated at 1250 A, 2000 MVA, 33 kV, 4s. Its making current capacity will be   (a) 35 kA (b) 89 kA (c) 79 kA (d) 69 kA

Last Answer : 89

Description : Ten signals, each requiring 3000 Hz, are multiplexed on to a single channel using FDM. How much minimum bandwidth is required for the multiplexed channel ? Assume that the guard bands are 300 Hz wide. (A) 30,000 (B) 32,700 (C) 33,000 (D) None of the above

Last Answer : (B) 32,700

Description : Air blast circuit breakers for 400 kV power system are designed to operate in (a) 100 microsecond (b) 50 millisecond (c) 0.5 sec (d) 0.1 sec

Last Answer : (b) 50 millisecond

Description : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately (A) P (B) 2P (C) P / 2 (D) P / 4

Last Answer : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately P / 4

Description : The X:R ratio of 220 kV line as compared to 400 kV line is?

Last Answer : The X:R ratio of 220 kV line as compared to 400 kV line is smaller.

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Description : Dietary requirement of Vitamin D: (A) 400 I.U. (B) 1000 I.U. (C) 6000 I.U. (D) 700 I.U.

Last Answer : Answer : A

Description : In glycoproteins the carbohydrate is in the form of disaccharide units, the number of units are (A) 50–100 (B) 200–300 (C) 400–500 (D) 600–700

Last Answer : Answer : D

Description : The recommended energy intake for an adult sedentary Indian woman is (A) 1,900 kcal/day (B) 2,200 kcal/day (C) 2,400 kcal/day (D) 2,700 kcal/day

Last Answer : Answer : A

Description : The recommended energy intake for an adult sedentary Indian man is (A) 1,900 kcal/day (B) 2,400 kcal/day (C) 2,700 kcal/day (D) 3,000 kcal/day

Last Answer : Answer : B

Description : The wavelength of visible light extends from a. 0.8 to 1.0 nm b. 400 to 750 nm c. 200 to 660 nm d. 700 to 1200 nm

Last Answer : b. 400 to 750 nm

Description : Which laser emits light in the visible range 400 to 700 nm? a. Argon-ion b. Nitrogen c. Carbon-dioxide d. Neodymium-YAG

Last Answer : a. Argon-ion

Description : The round-trip propagation delay between two earth stations through a geosynchronous satellite is A. 500 to 600 ms B. 300 to 400 ms C. 600 to 700 ms D. 400 to 500 ms

Last Answer : A. 500 to 600 ms

Description : At standard pressure and temperature the average speed of molecules is A. 400 m s-1 B. 500 m s-1 C. 600 m s-1 D. 700 m s-1

Last Answer : 400 m s-1