The eddy current loss in an a-c electric motor is 100 watts at 50 Hz. Its loss at 100
Hz will be
 (A) 25 watts (B) 59 watts
 (C) 100 watts (D) 400 watts

1 Answer

Answer :

(D) 400 watts

Related questions

Description : The eddy current loss in an AC motor is 100 watts at 50 Hz. Its losses at 100 Hz will be: (A) 25 watts (B) 59 watts (C) 100 watts (D) 400 watts

Last Answer : The eddy current loss in an AC motor is 100 watts at 50 Hz. Its losses at 100 Hz will be: 400 watts

Description : A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz supply with secondary winding open circuited. Then (A) Both eddy current and hysteresis losses decreases. (B) Both ... same but hysteresis loss increases. (D) Eddy current loss increases but hysteresis loss remains the same.

Last Answer : (A) Both eddy current and hysteresis losses decreases.

Description : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are (A) 140 W (B) 180 W (C) 240 W (D) 480 W

Last Answer : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are 240 W

Description : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is :  (A) 256 W (B) 320 W (C) 500 W (D) 625 W

Last Answer : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : 625 W

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : A 3 phase, 400 volts, 50 Hz, 100 kW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of: (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : 1470rpm

Description : An electrical connection between the wiring of an electric motor and its metal frame is known as a/an _____________. A. eddy current B. ground C. impedance D. flux leakage

Last Answer : Answer: B

Description : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the ... the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

Last Answer : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be 25.01 kW

Description : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are   (a) 32, 36 (b) 20, 36 (c) 25, 50 (d) 40, 80 

Last Answer : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are 20, 36

Description : If a transmission line has a power loss of 6 dB per 100 feet, what is the power at the feed point to the antenna at the end of a 200 foot transmission line fed by a 100 watt transmitter? A. 70 watts B. 50 watts C. 25 watts D. 6 watts

Last Answer : D. 6 watts

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for

Last Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : An AC generator produces 60 Hz at 1800 RPM. If the generator speed is increased to 1830 RPM, the cycles will _____________. A. remain at 60 Hz B. increase to 61 Hz C. decrease to 59 Hz D. increase to 63 Hz

Last Answer : Answer: B

Description : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be

Last Answer : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be 1165 Nm

Description : The rotor slots of a repulsion-type motor are generally skewed (placed nonparallel to the rotor axis) to _________. A. produce a constant starting torque B. permit a greater air gap with the starter C. permit a smaller air gap with the starter D. reduce eddy current losses

Last Answer : Answer: A

Description : The purpose of amortisseur windings in a synchronous motor is to ______________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : Amortisseur windings are installed in a synchronous motor to _____________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : When a synchronous motor is running at synchronous speed, the damper winding produces (A) damping torque. (B) eddy current torque. (C) torque aiding the developed torque. (D) no torque.

Last Answer : (D) no torque.

Description : Which of the following losses is/are present in every direct current generator armature? A. Winding copper loss B. Core eddy current loss C. Magnetic hysteresis loss D. All of the above.

Last Answer : Answer: D

Description : As an armature revolves within a magnetic field, friction is developed between the rotated magnetized particles as they pass through each magnetization cycle. This results in ____________. A. copper loss B. eddy-current loss C. hysteresis loss D. armature reaction

Last Answer : Answer: C

Description : How can eddy current loss be minimized?

Last Answer : By laminating the core.

Description : How do we minimize eddy current loss?

Last Answer : A. By laminating the core we can minimize eddy current loss.

Description : How to minimize Eddy current loss?

Last Answer : By using less thickness of laminations By using less value of Magnetic flux density

Description : What is Eddy current loss in transformer?

Last Answer : In transformer, we supply alternating current in the primary, this alternating current produces alternating magnetizing flux in the core and as this flux links with secondary winding, there will be induced ... dissipated as heat. This type of energy loss is called eddy current loss of transformer.

Description : The armature of a dc machine is laminated to reduce: (A) Eddy current loss (B) Hysteresis loss (C) copper losses (D) friction and windage losses

Last Answer : Ans: A Thinner the laminations, greater is the resistance offered to the induced e.m.f., smaller the current and hence lesser the I2R loss in the core.

Description : Two 100 watt light bulbs are connected in parallel across a 100 volt power supply. The total power developed in the circuit is _______________. A. 200 watts B. 100 watts C. 50 watts D. equal to the product of the amperes times the voltage in each branch

Last Answer : Answer: A

Description : Find the conductivity of a material with conduction current density 100 units and electric field of 4 units. a) 25 b) 400 c) 0.04 d) 1600

Last Answer : a) 25

Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.

Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.

Description : The power fed to a two-bay turnstile antenna is 100 watts. If the antenna has a 2 dB power gain, what is the effective radiated power? A. 317 watts B. 158 watts C. 200 watts D. 400 watts

Last Answer : B. 158 watts

Description : Two identical resistors are connected in parallel and consume 200 watts together. A third identical resistor is added in parallel. The total power consumed is: w) 100 watts x) 200 watts y) 300 watts z) 400 watts

Last Answer : ANSWER: Y -- 300 WATTS

Description : An electric clothes dryer is connected to a 100-volt source. How much current does it use if it requires 2,000 watts of electric power?

Last Answer : 20 Amphere

Description : The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be   (a) 0.30 kW/ph/km (b) 0.36 kW/ph/km (c) 028 kW/ph/km (d) 0.21 kW/ph/km

Last Answer : The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be 028 kW/ph/km

Description : On tank vessels with an electrically-driven capstan, the motor should be meggered periodically to test _____________. A. insulation resistance B. eddy currents C. capacitance D. armature reactance

Last Answer : Answer: A

Description : A vehicle suspension system consists of a spring and a damper. The stiffness of the spring is 3.6 kN/m and the damping constant of the damper is 400 Ns/m. If the mass is 50 kg, then the damping factor (d ) and damped natural ... , are a) 0.471 and 1.19 Hz b) 0.471 and 7.48 Hz c) 0.666 and 1.35 Hz

Last Answer : a) 0.471 and 1.19 Hz

Description : A vehicle suspension system consists of a spring and a damper. The stiffness of the spring is 3.6 kN/m and the damping constant of the damper is 400 Ns/m. If the mass is 50 kg, then the damping factor (d ) and damped natural ... .19 Hz b) 0.471 and 7.48 Hz c) 0.666 and 1.35 Hz d) 0.666 and 8.50 Hz

Last Answer : a) 0.471 and 1.19 Hz

Description : The magnetizing reactance of a 4 kV/ 400 V, 50 Hz single-phase transformer on low voltage side is 35 Ω. The magnetizing reactance on the high voltage side is (A) 0.35 Ω (B) 3.5 Ω (C) 350 Ω (D) 3500 Ω

Last Answer : 3500

Description : A 3-phase fully controlled bridge converter with free wheeling diode is fed from 400 V, 50 Hz AC source and is operating at a firing angle of 60o. The load current is assumed constant at 10 A due to high load inductance. The input ... 0.552 (C) IDF IPF = = 0.5; 0.478 (D) IDF IPF = = 0.5; 0.318 

Last Answer : A 3-phase fully controlled bridge converter with free wheeling diode is fed from 400 V, 50 Hz AC source and is operating at a firing angle of 60o. The load current is assumed constant at 10 A due to high ... (IDF) and the input power factor (IPF) of the converter will be IDF IPF = = 0.5; 0.478

Description : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be

Last Answer : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be 115 V.

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : Flicker noise is a poorly understood form of noise which may be completely ignored about above ____. A.100 Hz B. 200 Hz C. 400 Hz D. 500 Hz

Last Answer : D. 500 Hz

Description : A 10 Kg mass suspended by spring of stiffness 1000 N/m. the natural frequency of the system after giving excitation will be A. 0 Hz B. 1.59 Hz C. 2 Hz D. 15.9 Hz

Last Answer : B. 1.59 Hz

Description : The line trap unit employed in carrier current relaying: (A) offers high impedance to 50 Hz power frequency signal (B) offers high impedance to carrier frequency signal (C) offers low impedance to carrier frequency signal (D) Both (A) & (C)

Last Answer : Ans: B The line trap unit employed in carrier current relaying offers high impedance to carrier frequency signal. Because carrier frequency range is 35 km – 500 kHz XL = 2Π f l Where f increases XL will also increases

Description : A transformer has a turns ratio of two to one. If a 100 ohm resistor is connected on the high side, its resistance as measured on the low side would be: w) 25 ohms x) 50 ohms y) 100 ohms z) 400 ohms

Last Answer : ANSWER: W -- 25 OHMS

Description : The frequency of direct current is __. (1) Zero (2) 50 HZ (3) 60 HZ (4) 100 HZ

Last Answer : (1) Zero Explanation: Direct Current (DC) refers to power systems that use only one polarity of voltage or current, and to refer to the constant, zero-frequency, or slowly varying local mean value of a voltage or current.

Description : The frequency of direct current is _______ (1) Zero (2) 50 HZ (3) 60 HZ (4) 100 HZ

Last Answer : Zero

Description : Which one of the following units is used to measure intensity of noise? (A) decible (B) Hz (C) Phon (D) Watts/m2

Last Answer : (A) decible

Description : The normal range of plasma copper is (A) 25–50 µg/dl (B) 50–100 µg/dl (C) 100–200 µg/dl (D) 200–400 µg/dl

Last Answer : Answer : C