Description : The height gauge need to be provided in a) ROB b) RUB* c) FOB d) Fly Over
Last Answer : b) RUB*
Description : The minimum vertical clearance in RUB in urban area shall be a) 5870 mm b) 6525 mm c) 5000 mm d) 5500 mm*
Last Answer : d) 5500 mm*
Description : The minimum vertical clearance in RUB in rural area shall be a) 5870 mm b) 6525 mm c) 5000 mm* d) 5500 mm
Last Answer : c) 5000 mm*
Description : PSC is the abbreviation of…
Last Answer : Prestressed Concrete
Description : Abbreviation of BC is
Last Answer : Black cotton soil
Description : Abbreviation of C is …
Last Answer : Clay
Description : Abbreviation of S is …
Last Answer : Sand
Description : Abbreviation of BF is
Last Answer : Bottom of Foundation
Description : Abbreviation of CCN is …
Last Answer : Cement Concrete
Description : Abbreviation of ON is ….
Last Answer : Open Foundation
Description : . Disposal of Unserviceable materials is under Form No. S.1539… 23. Abbreviation of RL-BF is
Last Answer : Depth from rail level to bottom of foundation
Description : Abbreviation of HFL …
Last Answer : High Flood Level…
Description : Abbreviation of FOB …
Last Answer : Foot Over Bridge
Description : Abbreviation of URN …
Last Answer : Unique Rating Number
Description : Abbreviation of ORN
Last Answer : Overall Rating Number
Description : Abbreviation of CRN …
Last Answer : Conditional Rating Number
Description : . Abbreviation of NRS
Last Answer : Numerical Rating System
Description : Abbreviation of PTFE is……… 11. Trolley
Last Answer : Poly Tetra Fluoro Ethylene
Description : Abbreviation of DFT …
Last Answer : Dry Film Thickness
Description : What is the most important requirement for the people of a flood hit area?
Last Answer : Inoculation against cholera
Description : If a material has identical properties in all directions, it is called (a) Elastic (b) Plastic (c) Isotropic (d) Homogeneous
Last Answer : (c) Isotropic
Description : Both noting and protest are compulsory in case of A. Foreign Bills B. Inland Bills C. Foreign as well as Inland Bills D. None of them
Last Answer : C. Foreign as well as Inland Bills
Description : Power tillers are popularly available in hp range of q. 6-12 hp r. 12-20 hp s. 1-6 hp t. 20-50 hp
Last Answer : q. 6-12 hp
Description : The commonly used power transmission system in ferti seed drills are: a) China-sprocket and gears b) Gears and belt pulleys c) Belt pulleys and cams d) Belt pulleys and chain sprocket
Last Answer : d) Belt pulleys and chain sprocket
Description : The upper safe noise level for machine operator is : a. 85db b. 100db c. 110db d. 115db
Last Answer : a. 85db
Description : The average threshing outrun of a paddy in kg/hr is (A) 500 (B)650 (C)800 (D)1000
Last Answer : (B)650
Description : In a precision planter the height of seed drop: A. Should be as close to be ground level as is possible. B. Should be at least 1 m from the ground level. C. Is not a factor to be considered? D. None of These
Last Answer : A. Should be as close to be ground level as is possible.
Description : ate of wear chain drive system a) Directly related to speed of chain b) Inversely related to size of sprocket of chain length c) Both (a) and (b) d) None of the above
Last Answer : c) Both (a) and (b)
Description : Loading capacity of chain drive system is based on a) Rate of wear b) Ultimate strength of chain material c) None of (a) and (b) d) Both (a) and (b)
Last Answer : a) Rate of wear
Description : Formula for average service life of belt at a given speed is a) Life(hrs)= [ Belt length (mm)/ Total fatique rates]*100 b) Life(hrs)=[Total fatique rates / Belt length (mm)]*100 c) Life(hrs)=[Belt length (m)/ Total fatique rates]*100 d) None of the above
Last Answer : a) Life(hrs)= [ Belt length (mm)/ Total fatique rates]*100
Description : which stage represents optimum conditions for tillage a) Sticky b) Plastic c) Friable ( crumbly ). d) Hard ( cemented )
Last Answer : c) Friable ( crumbly
Description : Norms for No. of seats at recommended level at Cat. E stn. is (a) 0.4 Ndb (b) 0.4 Nds* (c) 0.4 Nmax (d) 100 on each P.F.
Last Answer : (b) 0.4 Nds*
Description : Norms for No. of seats at recommended level at Cat. D stn. is (a) 0.4 Ndb (b) 0.4 Nds* (c) 0.4 Nmax (d) 100 on each P.F.
Description : Norms for No. of seats at recommended level at Cat. C stn. is (a) 0.4 Ndb (b) 0.4 Nds* (c) 0.4 Nmax (d) 100 on each P.F.
Description : Norms for No. of seats at recommended level at Cat. B stn. is (a) 0.4 Ndb * (b) 0.4 Nds (c) 0.4 Nmax (d) 100 on each P.F.
Last Answer : (a) 0.4 Ndb
Description : Norms for No. of seats at recommended level at Cat. A stn. is (a) 0.4 Ndb* (b) 0.4 Nds (c) 0.4 Nmax (d) 100 on each P.F.
Last Answer : (a) 0.4 Ndb*
Description : As per norms for desirable amenity as given to model station, the retiring rooms should be provided on stations classified as --- (a) A & B* (b) A,B & C (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : a) A & B*
Description : As per norms for desirable amenity as given to model station, the clock rooms should be provided on stations classified as --- (a) A & B * (b) A,B & C (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : (a) A & B *
Description : As per norms for desirable amenity as given to model station, the water coolers should be provided on stations classified as --- (a) A & B (b) A,B & C (c) A,B,C & D* (d) A, B,C, D & E (e) A
Last Answer : (c) A,B,C & D*
Description : As per norms for desirable amenity as given to model station, the parking facility/circulating area should be provided on stations classified as --- (a) A & B (b) A,B & C (c) A,B,C & D* (d) A, B,C, D & E
Description : As per norms for desirable amenity as given to model station, the public address system should be provided on stations classified as --- (a) A & B (b) A,B & C* (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : (b) A,B & C*
Description : As per norms for desirable amenity as given to model station, the book stalls should be provided on stations classified as --- (a) A & B (b) A,B & C* (c) A,B,C & D (d) A, B,C, D & E (e) A
Description : As per norms for desirable amenity as given to model station, the refreshment rooms should be provided on stations classified as --- (a) A & B* (b) A,B & C (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : (a) A & B*
Description : Number of model stations identified for development on Indian Railways is about (a) 55 (b) 110* (c) 265 (d) 320
Last Answer : b) 110*
Description : Height of Low level platform for passengers for BG is --- high (a) 0.455 m* (b) 0.560 m (c) 0.650 m (d) 0.760 m
Last Answer : (a) 0.455 m*
Description : Height of high level platform for passengers for BG is --- high (a) 0.455 m (b) 0.560 m (c) 0.650 m (d) 0.760 m*
Last Answer : (d) 0.760 m*
Description : “B” class station is provided only on (a) Single lines (b) Double line (c) On both single as well as double line* (d) None of them
Last Answer : c) On both single as well as double line*
Description : Size of cubicle of a booking office is kept as (a) 1.20 x 1.50 m (b) 1.50 x 1.20 m (c) 1.50 x 1.80 m (d) 1.80 x 1.50 m*
Last Answer : (d) 1.80 x 1.50 m*
Description : Height of platform of a flag station in cutting above rail level is (a) Same height as Rail level (b) 305 mm above rail level (c) 455 mm above rail level (d) 840mm above rail level*
Last Answer : (d) 840mm above rail level*
Description : Which of the facilities do not exist at halt station? (a) Facilities for stopping the train (b) Facilities for a small waiting (c) Facilities for crossing of train* (d) Facilities for book of passengers
Last Answer : (c) Facilities for crossing of train*