What is the other name used for DC generators? A. Dynamos B. Alternator C. Capacitor D. Dynamotor 

1 Answer

Answer :

Dynamos is the other name used for DC generators.

Related questions

Description :  Which of the following generators is used for DC arc welding application ? (A) Series generator (B) Shunt generator (C) Differential compound generator (D) Over -compound generator

Last Answer : A

Description : Which of the methods listed is used to maintain the division of load between two compound-wound, DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt ... generators are connected in series. D. The equalizer connection parallels the series fields of all machines.

Last Answer : Answer: D

Description : An equalizing connection between two compound-wound DC generators when paralleled, serves to _____________. A. reverse the polarity of the incoming generator as the series field weakens B. automatically ... the series field of the incoming generator D. parallel the series fields of the generators

Last Answer : Answer: D

Description : AC and DC generators are similar in that they _____________. A. both generate alternating voltages B. both rectify the voltage before delivery C. are constructed at the same physical size for the same kilowatt rating D. both supply three-phase power

Last Answer : Answer: A

Description : Modern DC generators are fitted with commutating poles to _____________. A. prevent motorizing B. reduce sparking C. reduce the load on the main poles D. reduce spring pressure on the brushes

Last Answer : Answer: B

Description : Which of the methods listed is used to maintain equal load sharing between two compound wound DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt field rheostats ... are connected in series. D. The series fields of both generators are connected in parallel.

Last Answer : Answer: D

Description : In a diesel electric plant, raising the generator's field excitation will cause the DC propulsion motor to ________. A. increase in speed B. decrease in speed C. affect generator speed only D. affect main motor speed if done in conjunction with higher generator engine speeds

Last Answer : Answer: A

Description : What Is Basic Principle Of Operation Of Alternators/dc Generators?

Last Answer : They are working on the fundamental principle based on Faraday’s Laws of Electromagnetic Induction. This law states that, When a current carrying conductor moves in magnetic field, it induces an EMF.

Description : What Are The Major Parts Of The Dc Generators?

Last Answer : Yoke Poles Field winding Armature Armature winding Commutator brushes

Description : What Are The Conditions To Be Satisfied For Parallel Operation Of Dc Generators?

Last Answer : The polarities of the generators must be same or the connections must be interchanged till they become same. The voltages of both the generators must be equal. The change of voltage with ... and negative terminals of generators must be connected properly to the positive and negative of busbar.

Description : What is the basic difference between the primaries of ac and dc rate generators?

Last Answer : The method of primary excitation (ac and permanent magnet).

Description : What are the three classifications of dc generators?

Last Answer : Series-wound, shunt-wound, and compound-wound

Description : Why are drum-type armatures preferred over the Gramme ring armature in modern dc generators?

Last Answer : Drum-type armatures are more efficient, because flux lines are cut by both sides of each coil.

Description : In DC generators, armature reaction is produced actually by (A) Its field current. (B) Armature conductors. (C) Field pole winding. (D) Load current in armature.

Last Answer : Ans: D Because load current in armature gives rise to armature mmf which react with main field mmf.

Description : DC GENERATORS MCQ

Last Answer : 101. Wave winding is composed of (a) any even number of conductors (b) any odd number of conductors (c) that even number which is exact multiple of poles + 2 (d) that even number ... increase the field resistance (c) increase the speed of primemover (d) check armature insulation resis¬tance Ans: a

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Description : In DC generators, armature reaction is produced by the: (A) field current (B) armature conductors (C) field pole winding (D) load current in armature

Last Answer : In DC generators, armature reaction is produced by the: load current in armature

Description : In DC generators lamination core are generally made of?

Last Answer : In DC generators lamination core are generally made of silicon steel.

Description : Why are generators rated in kVA not in kW ?

Last Answer : Because It's rating of generator kva is apparent power. Kw is active power which we use. And one is kvar reactive power.

Description : Classify different types of generators.

Last Answer : Different Types of Generators:  1) Separately excited DC generator  2) Self excited DC generator: (i) DC series generator (ii) DC shunt generator (iii) DC Compound generator: short shunt and long shunt / (cumulative or differential) 

Description : Polyphase generators produce simultaneous multiple sinusoidal voltages that are separated by certain constant: A. Phase -angles B. Frequency C. Voltage D. Current

Last Answer : Polyphase generators produce simultaneous multiple sinusoidal voltages that are separated by certain constant: Phase -angles

Last Answer : The most appropriate operating speed in rpm of generators used in Thermal, Nuclear and Hydro-power plants would respectively be: 3000, 3000 and 300

Description : explain methods of generating time base waveform

Last Answer : time base generator generate high frequency sawtooth waves. Methods for generating time base waveforms 1. bootstrap circuit 2. Miller circuit 3. exponential charging

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : If three AC generators are operating in parallel, and one of them were to 'pull out' of synchronism with the other two generators, the ____________. A. normally operating AC generators will ... AC generators will overspeed and unload D. AC generator pulling out of synchronism will become motorized

Last Answer : Answer: B

Description : The removal of paint from electrical equipment, such as generators, should be cautiously undertaken because ____________. A. the mechanical shock of paint removal lessens the dielectric strength ... phase windings frequently become isolated from each other due to dust interference at the terminals

Last Answer : Answer: B

Description : Two AC generators of the same capacity are operating in parallel. One with a zero speed droop setting and the other with a 5% speed droop. If its capacity is not exceeded, the unit whose ... B. maintain the frequency of the system C. have poor sensitivity characteristics D. have poor power response

Last Answer : Answer: B

Description : You are attempting to parallel two AC generators and the synchroscope pointer stops at a position other than 0°. If you close the circuit breaker at this moment _____________. A. the incoming ... hazardous condition will be created by the incoming machine being at a higher frequency than the bus

Last Answer : Answer: C

Description : You are attempting to parallel two AC generators and the synchroscope pointer stops at a position other than 0° prior to closing the circuit breaker. This indicates ___________. A. the frequency of ... be closed after breaker has been reset D. there is an existing cross current between generators

Last Answer : Answer: A