Two wattmeters connected to measure the power input to a balanced three-phase circuit indicate 4.5 KW and 3 KW respectively. Find the power factor of the circuit. A. 0.7 B. 0.8 C. 0.95 D. 0 

1 Answer

Answer :

Two wattmeters connected to measure the power input to a balanced three-phase circuit indicate 4.5 KW and 3 KW respectively. Find the power factor of the circuit. 

0.95

Related questions

Description : Two wattmeters are used to measure the power in a 3 -phase balanced system. What is the power factor of the load when one wattmeter reads twice the other ?  (a) 0 (b) 0.5 (c) 0.866 (d) 1

Last Answer : Two wattmeters are used to measure the power in a 3 -phase balanced system. What is the power factor of the load when one wattmeter reads twice the other ?  0.866

Description : The power in a 3phase circuit is measured with the help of 2 wattmeters. The reading of one of wattmeters is positive and that of the others is negative. The magnitude of readings is different. It can be concluded that the ... (A) Unity (B) 2 (lagging) (C) 5 (lagging) (D) Less than 0.5 (lagging)

Last Answer : A

Description : The power delivered to a 3-phase load can be measured by the use of two wattmeters only when the  (a) load is unbalanced (b) load is balanced (c) three phase load is connected to the source through three wires (d) three phase load is connected to the source through four wires

Last Answer : The power delivered to a 3-phase load can be measured by the use of two wattmeters only when the three phase load is connected to the source through three wires 

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : Three equal impedances are first connected in delta across a 3 -phase balanced supply. If the same impedances are connected in star across the same supply then,

Last Answer : A

Description : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

Last Answer : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be 0.5 lagging.

Description : In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?

Last Answer : In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?  0.5

Description : Define balanced and unbalanced load in three phase circuit.

Last Answer : Balanced Load: When all the imedances of 3 phases are equal in magnitude and of same nature then load is said to be balanced.  Unbalanced Load: When all the imedances of 3 phases are not equal in magnitude and of different nature then load is said to be unbalanced.

Description : The minimum number of wattmeter(s) required to measure 3-phase, 3-wire balanced or unbalanced power is  A) 1 B) 2 C) 3 D) 4

Last Answer : B

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : What is the advantage of using in-line wattmeters over output power meters?

Last Answer : Most in-line wattmeters are capable of measuring both forward and reflected power.

Last Answer : The power measurement in a balanced 3-phase circuit can be done by: One wattmeter method, Two wattmeter method, Three wattmeter method.

Description : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is :

Last Answer : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is : 200 V

Description : What should be kVA rating of each transformer in V-V bank when three phase balanced load is 40 kVA ? (A) 19 (B) 28 (C) 37 (D) 23

Last Answer : What should be kVA rating of each transformer in V-V bank when three phase balanced load is 40 kVA ? (A) 19 (B) 28 (C) 37 (D) 23

Description : In a three-phase system, when the loads are perfectly balanced, the value of neutral current is equal to: A. Zero B. One-third of the maximum value C. Two -third of the maximum value D. The maximum value

Last Answer : In a three-phase system, when the loads are perfectly balanced, the value of neutral current is equal to: Zero

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m

Last Answer : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: 75 r.p.m

Description : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is

Last Answer : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is constant

Description : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

Last Answer : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is 30°

Description : What type of device is used to extend the current measuring capability of electrodynamic wattmeters?

Last Answer : Current transformers.

Last Answer : For handling greater currents induction wattmeters are used in conjunction with current transformers.

Description : Why the input resistance of an ideal OPAMP is infinite and output resistance is zero? secondly, how can we measure these resistances(input and output) in case of an ideal OPAMPand Real OP-AMP in the following conditions when 1- load is not connected. 2- load is connected.

Last Answer : Ans- Ideal OP-AMP is a power ful concept. If one goes through the history of amplifying devices it becomes clear that less it loads the previous stage better the output signal. ie ... . Can refer application notes by device manufacturer available in internet for more precise and practical solutions.

Description : The power input to the rotor of a 400V, 50 Hz 6 pole three phase induction motor is 20kW. The slip is 3%. The frequency of rotor currents is: (A) 1 Hz (B) 1.5 Hz (C) 2 Hz (D) 1 2 Hz

Last Answer : C

Description : In a Y -connected circuit, between each line -voltage and the nearest phase - voltage, there is a phase -angle of: A. 0° B. 30° C. 60° D. 120°

Last Answer : B

Description : In the illustrated circuit, what is the phase relationship of the amplifier output compared to the input? EL-0022 A. 0° in-phase B. 180° out of phase C. phase angle of the input divided by power factor D. unable to determine without the value of the bias voltage

Last Answer : Answer: B

Description : A three-phase star -connected load is operating at a power factor angle ϕ  with ϕ being the angle between

Last Answer : A three-phase star -connected load is operating at a power factor angle ϕ  with ϕ being the angle between Phase voltage and phase current

Description : Indicate the false statement. Noise figure is defined as A. the ratio of the S/N power supplied at the input terminal of a receiver or amplifier to the S/N power supplied to the output or ... under test, both working at the same temperature over the same bandwidth and fed from the same source

Last Answer : C. an unwanted form of energy tending to interfere with the proper and easy reception and reproduction of wanted signals

Description : If you obtain a low resistance reading with a megohmmeter connected between terminals 'A' and 'C' of the three-phase, wye-connected winding shown in the illustration, there is __________. EL-0074 A. no open circuit ... 'B' C. an open circuit between 'A' and 'C' D. an open circuit in both windings

Last Answer : Answer: A

Description : In testing a three-phase delta winding for an open circuit using a megohmmeter, you must ______________. A. test each phase with all connections intact B. measure the voltage across the open ... groups to avoid short circuiting D. open the delta-connections to avoid shunting the phase being tested

Last Answer : Answer: D

Description : Illustrate how can you use a single-phase wattmeter to measure 3 phase reactive power in a circuit?

Last Answer : We can measure reactive power of 3 phase circuit by dingle phase wattmeter by connecting the current coil in series with a line or load and connecting the pressure coil across the other two lines.  Reactive power = 3√ V * I * sinϕ Watts. 

Last Answer : Req= (1/1200 +1/560 + 1/2.1)^-1        = 2.1 ohms RT= 2.1 + 7.8      = 9.9 ohms IT = V/R = 24/9.9                = 2.4 A Veq= R I =  2.1 2 ... 7.8         = 12.096 w                 = 44.928 w _________________________________________ By: Ellis-Junior Kamatjipose [email protected]

Description : Define balanced 3 phase load.

Last Answer : Balanced 3 phase Load: Balanced three phase load is defined as star or delta connection of three equal impedances having equal real parts and equal imaginary parts. It takes same current of equal magnitude and equal phase angle.

Description : At a particular instant, the R-phase voltage of a balanced 3-phase system is + 30 V, and the Y-phase voltage is – 90 V. The voltage of B-phase at that instant is (A) + 120 V (B) – 120 V (C) – 60 V (D) + 60 V

Last Answer : At a particular instant, the R-phase voltage of a balanced 3-phase system is + 30 V, and the Y-phase voltage is – 90 V. The voltage of B-phase at that instant is + 60 V

Description : In the illustration, the signal from the device connected to terminals 18 and 19 is __________. EL-0046 A. prime mover speed feedback B. loss of control alarm when comparing with the input signal ... slip between the prime mover and the alternator D. to shut down the prime mover if overspeeding

Last Answer : Answer: A

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : Draw sinusoidal waveform of 3 phase emf and indicate the phase sequence.

Last Answer : Phase sequence is R-Y-B.

Description : Two resistors `400Omega` and `800Omega` are connected in series with a `6V` battery. It is desired to measure the current in the circuit. An ammeter o

Last Answer : Two resistors `400Omega` and `800Omega` are connected in series with a `6V` battery. It is desired to measure the current ... .95` V C. `3.8` V D. 4 V

Description : In a three phase half wave rectifier feeding resistive load, if the input source is a three phase 4 wire system and line to line voltage is 100 V. The supply frequency is 400 Hz. The ripple frequency at the output is: (1) 400 Hz (2) 800 Hz (3) 1200 Hz (4) None of these

Last Answer : In a three phase half wave rectifier feeding resistive load, if the input source is a three phase 4 wire system and line to line voltage is 100 V. The supply frequency is 400 Hz. The ripple frequency at the output is: 1200 Hz

Description : Transmission lines are either balanced or unbalanced with respect to _________. A. negative terminal B. input C. ground D. positive terminal

Last Answer : C. ground

Description : The advantage of using the illustrated circuit configuration is _________. EL-0045 A. high input resistance B. high current gain C. the best stability with an increase in temperature D. the input and output are 180 degrees out of phase

Last Answer : Answer: C

Description : Which of the following is not true: A) An oscillator is a circuit that converts DC to AC B) An oscillator is an amplifier that supplies its own input signal C) All oscillators generate sine waves D) In phase feedback is called positive Feedback

Last Answer : C) All oscillators generate sine waves

Description : The circuit which changes input signal at output with phase shift of 1800 is called (a) Amplifier (b) operational amplifier (c) switch (d) inverter

Last Answer : (d) inverter

Description : In a 3-phase 4-wire distribution system three unbalanced but equal magnitude impedances are connected between respective lines and neutral. The magnitude of current in the neutral conductor for RYB and RBY phase sequences ... ) zero (B) same (C) different (D) same in magnitude but differs in phase.

Last Answer : In a 3-phase 4-wire distribution system three unbalanced but equal magnitude impedances are connected between respective lines and neutral. The magnitude of current in the neutral conductor for RYB and RBY phase sequences are different 

Description : In a certain three -wire Y -connected generator, the phase voltages are 2 kV. The magnitudes of the line voltages will be: A. 2,000 V B. 6,000 V C. 666 V D. 3,464 V

Last Answer : In a certain three -wire Y -connected generator, the phase voltages are 2 kV. The magnitudes of the line voltages will be: 3,464 V

Description : The maximum possible power of a 3-phase synchronous motor with synchronous reactance 0.8 p.u. connected to a bus-bar of 1.0 p.u. and excitation adjusted to 1.2 p.u. is (A) 0.5 p.u. (B) 0.96 p.u. (C) 1.5 p.u. (D) 1.8 p.u.

Last Answer : The maximum possible power of a 3-phase synchronous motor with synchronous reactance 0.8 p.u. connected to a bus-bar of 1.0 p.u. and excitation adjusted to 1.2 p.u. is 1.5 p.u.

Description : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ?  (a) 100 VAR (b) 200 VAR (c) 300 VAR (d) 400 VAR

Last Answer : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ? 400 VAR

Description : A full adder is a combinational circuit that performs the arithmetic sum of three input bits and produces a (a) sum output (b) sum output and a carry (c) sum output with two carries (d) two sums with two carries

Last Answer : A full adder us an a combination logical circuit which will produces an sum and carry when ever more than two inputs were given.