In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?

1 Answer

Answer :

In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ? 

0.5

Related questions

Description : Two wattmeters connected to measure the power input to a balanced three-phase circuit indicate 4.5 KW and 3 KW respectively. Find the power factor of the circuit. A. 0.7 B. 0.8 C. 0.95 D. 0 

Last Answer : Two wattmeters connected to measure the power input to a balanced three-phase circuit indicate 4.5 KW and 3 KW respectively. Find the power factor of the circuit.  0.95

Description : What should be kVA rating of each transformer in V-V bank when three phase balanced load is 40 kVA ? (A) 19 (B) 28 (C) 37 (D) 23

Last Answer : What should be kVA rating of each transformer in V-V bank when three phase balanced load is 40 kVA ? (A) 19 (B) 28 (C) 37 (D) 23

Description : At a particular instant, the R-phase voltage of a balanced 3-phase system is + 30 V, and the Y-phase voltage is – 90 V. The voltage of B-phase at that instant is (A) + 120 V (B) – 120 V (C) – 60 V (D) + 60 V

Last Answer : At a particular instant, the R-phase voltage of a balanced 3-phase system is + 30 V, and the Y-phase voltage is – 90 V. The voltage of B-phase at that instant is + 60 V

Description : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

Last Answer : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is 30°

Description : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

Last Answer : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be 0.5 lagging.

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : A 200 V, 50 Hz inductive circuit takes a current of 10 A at 30 degree lagging pf, what is the inductive reactance of the circuit?  (A) 17.8 Ω (B) 100 Ω (C) 178 Ω (D) 10 Ω 

Last Answer : D

Description : Define balanced and unbalanced load in three phase circuit.

Last Answer : Balanced Load: When all the imedances of 3 phases are equal in magnitude and of same nature then load is said to be balanced.  Unbalanced Load: When all the imedances of 3 phases are not equal in magnitude and of different nature then load is said to be unbalanced.

Description : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ?  (a) 100 VAR (b) 200 VAR (c) 300 VAR (d) 400 VAR

Last Answer : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ? 400 VAR

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Last Answer : The power measurement in a balanced 3-phase circuit can be done by: One wattmeter method, Two wattmeter method, Three wattmeter method.

Description : Assume a frequency of 4 MHz, determine the phase shift offered by the line in the above problem. A. 108.5˚ B. 106.5˚ C. 115.5˚ D. 166.5˚

Last Answer : D. 166.5˚

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 470 ohms the current will be _______. EL-0018 A. 244 milliamps B. 4.07 amps C. 5.85 amps D. 19.21 amps

Last Answer : Answer: A

Description : If a voltage of 125 VDC is applied to the illustrated circuit where the resistance of R1 is 12 ohms, and R2 is 115 ohms, the current will be_______. EL-0019 A. 11.5 amps B. 12.5 amps C. 115 amps D. 125 amps

Last Answer : Answer: A

Description : In a three-phase system, when the loads are perfectly balanced, the value of neutral current is equal to: A. Zero B. One-third of the maximum value C. Two -third of the maximum value D. The maximum value

Last Answer : In a three-phase system, when the loads are perfectly balanced, the value of neutral current is equal to: Zero

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 17.8 ohms the current will be _______. EL-0018 A. 0.154 amps B. 2.755 amps C. 6.46 amps D. 0.1328 amps

Last Answer : Answer: C

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 237 ohms the current will be _______. EL-0018 A. 0.485 amps B. 1.485 amps C. 2.06 amps D. 0.352 amps

Last Answer : Answer: A

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 10,230 ohms the current will be _______ EL-0018 A. 88.95 milliamps B. 103.45 milliamps C. 11.24 milliamps D. 0.91 amps

Last Answer : Answer: C

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 32 ohms the current will be _______. EL-0018 A. 278.26 amps B. 147.00 amps C. 8.90 amps D. 3.59 amps

Last Answer : Answer: D

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 12 ohms the current will be _______. EL-0018 A. 127 amps B. 9.58 amps C. 104.34 amps D. 1.24 amps

Last Answer : Answer: B

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 110 ohms the current will be _______. EL-0018 A. 1.045 amps B. 225 milliamps C. 2.045 amps D. 965.52 milliamps

Last Answer : Answer: A

Description : When a voltage of 115 VDC is applied to the illustrated circuit with a resistance of 1.74 ohms the current will be _______. EL-0018 A. 66.09 amps B. 116.74 amps C. .026 amps D. .015 amps

Last Answer : Answer: A

Description : In a series RC circuit, 12 V (rms) is measured across.the resistor and 15 V (rms) is measured across the capacitor. The value of rms source voltage is: A. 3 V B. 27 V C. 19.2 V D. 1.9 V

Last Answer : In a series RC circuit, 12 V (rms) is measured across.the resistor and 15 V (rms) is measured across the capacitor. The value of rms source voltage is: 19.2 V

Description : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are   (a) 32, 36 (b) 20, 36 (c) 25, 50 (d) 40, 80 

Last Answer : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are 20, 36

Description : Three audio waves with 100,200 and 300 volts amplitude respectively, simultaneously modulate a 450 volts carrier. What is the total percent of modulation of the AM wave? A. 69 % B. 115.5 % C. 50% D. 83%

Last Answer : D. 83%

Description : Two wattmeters are used to measure the power in a 3 -phase balanced system. What is the power factor of the load when one wattmeter reads twice the other ?  (a) 0 (b) 0.5 (c) 0.866 (d) 1

Last Answer : Two wattmeters are used to measure the power in a 3 -phase balanced system. What is the power factor of the load when one wattmeter reads twice the other ?  0.866

Description : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is

Last Answer : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is constant

Description : Two unpedauces given by Z1 = 10 + j5 and Z2 = 8 + j9 are joined in parallel and connected across a voltage of V = 200 + j0. Calculate the circuit current and branch currents. Draw the vector diagram.

Last Answer : Solution: Given, Z1=10+j5, Z2=8+j9, V=200+j0

Description : The prescribed hardness limit of potable water ranges between  (A) 50 to 75 P.P.M.  (B) 75 to 115 P.P.M.  (C) 100 to 150 P.P.M.  (D) 150 to 200 P.P.M.

Last Answer : (B) 75 to 115 P.P.M. 

Description : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be

Last Answer : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be 1165 Nm

Description : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is (A) zero (B) 0.5 (C) between zero and 0.5 (D) between 0.5 and unity

Last Answer : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is between 0.5 and unity

Description :

Last Answer : A voltage of about 200 V can be measured a D.C. potentiometer in conjunction with a volt ratio box.

Last Answer : The power of a n-phase circuit can be measured by using a minimum of (n - 1) wattmeter elements

Description : Which of the following is standardized as part of GSM phase 2+ that can offer theoretical data speeds of upto 115 kbit/s? A. EDGE B. GPRS C. WAP D. Bluetooth

Last Answer : B. GPRS

Last Answer : Req= (1/1200 +1/560 + 1/2.1)^-1        = 2.1 ohms RT= 2.1 + 7.8      = 9.9 ohms IT = V/R = 24/9.9                = 2.4 A Veq= R I =  2.1 2 ... 7.8         = 12.096 w                 = 44.928 w _________________________________________ By: Ellis-Junior Kamatjipose [email protected]

Description : During Phase 2 of action potential in cardiac cell, depolarizing current through calcium channels is balanced by (a) Delayed rectifier potassium current (b) outward chloride channel (c) Both (a) and (b) (d) None of the above

Last Answer : Ans: A

Description : Define balanced 3 phase load.

Last Answer : Balanced 3 phase Load: Balanced three phase load is defined as star or delta connection of three equal impedances having equal real parts and equal imaginary parts. It takes same current of equal magnitude and equal phase angle.

Description : Three equal impedances are first connected in delta across a 3 -phase balanced supply. If the same impedances are connected in star across the same supply then,

Last Answer : A

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m

Last Answer : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: 75 r.p.m

Description : A healthy 70 kg man eats a well balanced diet containing adequate calories and 62.5 g of high quality protein per day. Measured in grams of nitrogen, his daily nitrogen balance would be (A) +10 g (B) +6.25 g (C) 0 g (D) –6.25 g

Last Answer : Answer : C

Description : When the circuit shown in the illustration is operating correctly, the voltage at the reference electrode will be kept in the optimum range of ____________. EL-0090 A. 0.01 - 0.05 volt B. 0.80 - 0.85 volt C. 35 - 60 volts D. 100 - 115 volts

Last Answer : Answer: B

Description : The product of apparent power and cosine of the phase angle between circuit voltage and current is?

Last Answer : In parllpar reasonans RLC circuit the current is

Description : The power consumed in a circuit element will be least when the phase difference between the current and voltage is?

Last Answer : The power consumed in a circuit element will be least when the phase difference between the current and voltage is 90°.

Description : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the A. Load is balanced B. 3 -phase load is connected to the source through 3 wires C. Load is unbalanced D. 3 -phase load is connected to the source through 4 wires

Last Answer : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the  Load is unbalanced

Description : The minimum number of wattmeter(s) required to measure 3-phase, 3-wire balanced or unbalanced power is  A) 1 B) 2 C) 3 D) 4

Last Answer : B

Description : In a 3-phase half-wave rectifier, if per phase input is 200 V, then the average output voltage is   (a) 233.91 V (b) 116.95V (c) 202.56 V (d) 101.28V 

Last Answer : a

Description : A 10 kVA, 400 V/200 V single phase transformer with 10% impedance draws a steady short-circuit line current of   (a) 250A (b) 50 A (c) 150 A (d) 350 A 

Last Answer : A 10 kVA, 400 V/200 V single phase transformer with 10% impedance draws a steady short-circuit line current of 250A

Description : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

Last Answer : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Description : The power in a 3phase circuit is measured with the help of 2 wattmeters. The reading of one of wattmeters is positive and that of the others is negative. The magnitude of readings is different. It can be concluded that the ... (A) Unity (B) 2 (lagging) (C) 5 (lagging) (D) Less than 0.5 (lagging)

Last Answer : A